EEWORLDEEWORLDEEWORLD

Part Number

Search

8345-F02A-U3K2-DB1B1C-100A

Description
cir brkr thrm 100a
CategoryCircuit protection   
File Size648KB,10 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet View All

8345-F02A-U3K2-DB1B1C-100A Online Shopping

Suppliers Part Number Price MOQ In stock  
8345-F02A-U3K2-DB1B1C-100A - - View Buy Now

8345-F02A-U3K2-DB1B1C-100A Overview

cir brkr thrm 100a

Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
Description
Single or multipole hydraulic-magnetic circuit breakers with trip-free-
mechanism and toggle actuation. A choice of switching characteristics
ensures suitability for a wide range of applications. Industry standard
dimensions and panel mounting. Auxiliary contacts optional. Low
temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934) S-type HM CBE.
Typical applications
In the business fields Communication and Transport: power supplies,
switchgear, instrumentation and process control engineering.
1-pole
Standard current ratings and typical internal resistance values
Current rating (A)
Trip curves and internal
resistance (Ω) per pole
K1, M1, T1
0.05
0.1
1
2
3
5
10
15
20
25
30
40
50
60
80
100
125
452
100
0.95
0.26
0.10
0.042
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
M2, T2
376
94
0.90
0.20
0.10
0.040
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
8345
2-pole
Technical data
Voltage rating
3 AC 415 V; AC 277/480 V;
AC 120/240 V; AC 240 V; DC 80 V
(higher DC voltages to special order)
0.05...125 A single and multipole
higher ratings upon request
AC 240 V 6 A
DC 28 V 3 A
DC 65 V 1 A
DC 80 V 0.5 A
10,000 operations at 1 x I
N
-40...+85 °C (-40...+185 °F)
2.5 kV/2
reinforced insulation in operating area
test
test
test
test
test
voltage
voltage
voltage
voltage
voltage
AC
AC
AC
AC
AC
3,000
1,500
1,500
3,000
1,500
V
V
V
V
V
Current rating range
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664)
Dielectric strength
operating area
Line to Load
pole to pole
(2- and 3-pole)
main to auxiliary circuit
switching to trip circuit
(version -X)
Insulation resistance
Degree of protection
(IEC 60529)
Vibration
upside down:
directions 1, 2, 3, 4, 5:
with curves F1, F2:
4
> 100 MΩ (DC 500 V)
operating area IP40
terminal area IP00
10 g (57-2000 Hz) ± 0,76 mm (10-57 Hz)
at 0.9 I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ± 0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
,
100 g (11 ms) at 0.8 x I
N
,
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 90 - 120 g per pole
depending on version
Interrupting capacity
to EN 60934, CCC, UL 489, UL 1077
IEC 60934 / CCC (3-pole) – test series E:
voltage
DC 80 V
AC 240/415 V
AC 240 V
voltage
DC 80 V
AC 120 V
AC 120/240 V
AC 240 V
voltage
DC 80 V
AC 277/480 V
number of
poles
1+2
1 - (6)
1
number of
poles
1+2
1
1 (2)
1
UL 1077:
number of
poles
1+2
1-6
I
N
max. (A)
0.02...125
0.02...70
I
cn
(A)
10 000
5 000
I
N
max. (A)
0.02...125
0.02...80
0.02...20
I
N
max. (A)
0.5...125
0.5...80
0.5...80
0.5...20
I
cn
(A)
10 000
6 x I
N
5 000
I
cn
(A)
10 000
5 000
5 000
5 000
UL 489 – test sequence Z:
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
2015/16
www.e-t-a.de
4
- 25
What are you looking forward to in this oscilloscope-themed event?
[font=微软雅黑][size=3]:pleased:Oscilloscopes always attract much attention in the annual chip coin bidding activities, and this year is no exception (not yet ended [url=https://bbs.eeworld.com.cn/thread-...
nmg Test/Measurement
National Semiconductor LM10504, LMZ12003, LMZ14203 Device Data Analysis
[table=50%][tr][td] Part Number[/td][td] Click to Download[/td][td] Description[/td][/tr][tr][td] LM10504[/td][td] [/td][td] 4A Version, Pin-Pin Compatible[/td][/tr][tr][td] LMZ12003[/td][td] [/td][td...
wanggq Power technology
Wireless remote control stepper motor
Wireless remote control stepper motor...
shifanno1 RF/Wirelessly
Is it possible to cascade two CS8900A and connect them to s3c2410A to achieve dual network ports? ?
Is it possible to cascade two CS8900A and connect them to s3c2410A to realize dual network ports? If it is possible or not, what problems do you think will exist? Because my graduation project is to r...
2019230 Embedded System
The device search function on the home page is no longer available?
Why does it show services unavailable when I click it? Can you please check it? Is there a problem?...
范小川 Talking
【TI Course】How can I learn the complete course? How do I need to pay and how do I pay?
How can I complete the course? How do I pay?...
yuxun TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2723  1818  1940  383  949  55  37  40  8  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号