EEWORLDEEWORLDEEWORLD

Part Number

Search

8N4SV75BC-0020CDI8

Description
IC osc vcxo 106.25mhz 6-clcc
Categorysemiconductor    Analog mixed-signal IC   
File Size63KB,10 Pages
ManufacturerIDT (Integrated Device Technology, Inc.)
Websitehttp://www.idt.com/
Environmental Compliance  
Download Datasheet View All

8N4SV75BC-0020CDI8 Online Shopping

Suppliers Part Number Price MOQ In stock  
8N4SV75BC-0020CDI8 - - View Buy Now

8N4SV75BC-0020CDI8 Overview

IC osc vcxo 106.25mhz 6-clcc

Default Frequency and VCXO Pull Range
Order Information for Ceramic 5x7 Devices
ORDERING INFORMATION
Ordering Information for FemtoClock
®
NG Ceramic-Package XO and VCXO Products
The programmable VCXO and XO devices support a variety of
devices options such as the output type, number of default frequen-
cies, internal crystal frequency, power supply voltage, ambient
temperature range and the frequency accuracy. The device options,
default frequencies and VCXO pull range must be specified at the
time of order and are programmed by IDT before the shipment. Table
1 specifies the available order codes including the device options.
Table 2 to table 4 specify the default frequency configurations.
Example part number: order code 8N3QV01FD-0001CDI specifies a
programmable, quad default-frequency VCXO with a voltage supply
of 2.5V, a LVPECL output, a
50
ppm crystal frequency accuracy,
contains a 114.285MHz internal crystal as frequency source,
industrial temperature range, a lead-free (6/6 RoHS) 10-lead ceramic
5mm x 7mm x 1.55mm package and is factory-programmed to the
default frequencies of 100, 122.88, 125 and 156.25MHz and to the
VCXO pull range of min.
100
ppm. The default frequency
configuration is found in table 1.
Other default frequencies and order codes are available from IDT on
request.
Look up default frequencies from tables 2, 3 and 4 by using the
left-most frequency column for single-frequency devices, the two
left-most columns for dual and all four columns for quad-frequency
devices, respectively.
Table 1. Order Codes
8N X
X
XXX X X - dddd XX X
X
Shipping Package
8:
Tape & Reel
(no letter): Tray
Ambient Temperature Range
“I”: Industrial: (T
A
= -40°C to 85°C)
(no letter) : (T
A
= 0°C to 70°C)
Package Code
CD:
Lead-Free, 6/10-lead ceramic 5mm x 7mm x 1.55mm
Number of Default Frequencies
S:
1: Single
D:
2: Dual
Q:
4: Quad
Default-Frequency and VCXO Pull Range
See
document
FemtoClock NG Ceramic-Package XO and VCXO
Ordering Product Information.
dddd
Part Number
Function #Pins
001
003
V01
V03
V75
V76
V85
085
270
271
272
273
XO
XO
VCXO
VCXO
VCXO
VCXO
VCXO
XO
XO
XO
XO
XO
10
10
10
10
6
6
6
6
6
6
6
6
OE fct. at
pin
OE@2
OE@1
OE@2
OE@1
OE@2
nOE@2
OE@1
OE@1
OE@2
nOE@2
nOE@1
Die Revision
G
Option Code (Supply Voltage and Frequency-Stability)
A:
V
CC
= 3.3V±5%, ±100ppm
B:
V
CC
= 2.5V±5%, ±100ppm
E:
V
CC
= 3.3V±5%, ±50ppm
F:
V
CC
= 2.5V±5%, ±50ppm
K:
V
CC
= 3.3V±5%, ±20ppm
L:
V
CC
= 2.5V±5%, ±20ppm
Last digit =
L:
configuration pre-programmed and not changable
0000
to
0999
1000
to
1999
2000
to
2999
f
XTAL
(MHz)
114.285
100.000
PLL feedback
Fractional
Integer
Fractional
Use for
VCXO, XO
XO
XO
Table
2
3
4
FemtoClock NG
I/O Identifier
0:
LVCMOS
3:
LVPECL
4:
LVDS
REVISION 24 MARCH 28, 2012
1
©2012 Integrated Device Technology, Inc.
Brief Introduction of Spectrometer Measurement Circuit
Here is an introduction to the measurement circuit of spectral instrumentsSpectroscopic instruments include a variety of commonly used measuring instruments for laboratory tests, such as plasma emissi...
aiwenzx Test/Measurement
Board throughput is too low
The throughput of the board is too low, but there seems to be no problem with the hardware. The hardware cache of the network card is 1k. I don’t know if it is because of the system’s processing perfo...
hustforest Embedded System
Design of simple password lock
[color=#336699]Design of simple password lock, ISIS simulation program[/color]...
晴天余霞 51mcu
Unable to debug the program in C, please help!!!
Please help me, experts.When I use CCS to debug a C program,why can I only single-step in the disassembly, but not in the C program? ?Every time I click go main, it automatically switches to the disas...
lemonnofeeling Analogue and Mixed Signal
Digital Content Protection HDCP Compatibility Test Revealed
HDCP (High-Bandwidth Digital Content Protection) is a technology developed by Intel subsidiary Digital Content Protection LLC (DCP) to protect digital entertainment content, ensuring that digital imag...
黑衣人 Test/Measurement
Why should the water flow switch be installed on the pipe section flowing from bottom to top when installed vertically?
Why should the water flow switch be installed on the pipe section flowing from bottom to top when installed vertically?...
草原狼1 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 157  1492  1145  158  1705  4  31  24  35  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号