Part Number

Search

T83E336M025USZL

Description
MOLDED CASE, HI-REL COTS SOLID TANTALUM SURFACE MOUNT CAPACITOR
CategoryPassive components    capacitor   
File Size460KB,19 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Environmental Compliance  
Download Datasheet Parametric View All

T83E336M025USZL Overview

MOLDED CASE, HI-REL COTS SOLID TANTALUM SURFACE MOUNT CAPACITOR

T83E336M025USZL Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid1295767415
package instruction, 2917
Reach Compliance Codecompliant
Country Of OriginIsrael
ECCN codeEAR99
YTEOL6.98
capacitance33 µF
Capacitor typeTANTALUM CAPACITOR
dielectric materialsTANTALUM (DRY/SOLID)
ESR200 mΩ
high4 mm
JESD-609 codee3
length7.3 mm
Installation featuresSURFACE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, 7 Inch
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)25 V
size code2917
surface mountYES
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
Terminal shapeJ BEND
width4.3 mm
T83
www.vishay.com
Vishay Sprague
Solid Tantalum Surface Mount Chip Capacitors
T
ANTAMOUNT®
, Molded Case, Hi-Rel COTS
FEATURES
Standard and low ESR options
Weibull grading and surge current test options
Available
Terminations: 100 % matte tin and tin / lead
Standard EIA 535BAAC case sizes (A through E)
Available
Moisture sensitivity level 1
Compliant terminations
High reliability
Material categorization: for definitions of compliance
please see
www.vishay.com/doc?99912
PERFORMANCE / ELECTRICAL
CHARACTERISTICS
www.vishay.com/doc?40209
Operating Temperature:
-55 °C to +125 °C
(above 85 °C, voltage derating is required)
Capacitance Range:
0.1 μF to 470 μF
Capacitance Tolerance:
± 10 %, ± 20 %
Voltage Rating:
4 V
DC
to 63 V
DC
Note
*
This datasheet provides information about parts that are
RoHS-compliant and / or parts that are non-RoHS-compliant. For
example, parts with lead (Pb) terminations are not RoHS-compliant.
Please see the information / tables in this datasheet for details.
APPLICATIONS
Industrial
Medical
Military / aerospace
Telecom
ORDERING INFORMATION
T83
TYPE
D
CASE
CODE
See
Ratings
and
Case
Codes
table.
107
CAPACITANCE
This is expressed
in picofarads. The
first two digits are
the significant
figures. The third
is the number of
zeros to follow.
K
CAPACITANCE
TOLERANCE
K = ± 10 %
M = ± 20 %
J=±5%
(special order)
010
DC VOLTAGE
RATING AT +85 °C
This is expressed in
volts. To complete
the three-digit block,
zeros precede the
voltage rating. A
decimal point is
indicated by an “R”
(6R3 = 6.3 V).
E
TERMINATION
AND PACKAGING
See table
Termination and
Packaging Codes
A
RELIABILITY
LEVEL
A = 1.0 %
B = 0.1 %
C = 0.01 %
S = hi-rel
standard
Z = non-ER
A
SURGE
CURRENT
A = 10 cycles at
+25 °C
B = 10 cycles at
-55 °C / +85 °C
C = 10 cycles at
-55 °C / +85 °C
(before Weibull
grading)
Z = none
S = 3 cycles
at +25 °C
S
ESR
S = std
L = low
TERMINATION AND PACKAGING CODES
CODE
C
H
U
E
L
R
K
M
N
TERMINATION
Matte tin
Matte tin
Matte tin
Solder plated, tin / lead
Solder plated, tin / lead
Solder plated, tin / lead
Solder fused, tin / lead
Solder fused, tin / lead
Solder fused, tin / lead
PACKAGING
7" (178 mm) reels
7" (178 mm) reels, ½ reel
7" (178 mm) reels, partial reel
7" (178 mm) reels
7" (178 mm) reels, ½ reel
7" (178 mm) reels, partial reel
7" (178 mm) reels
7" (178 mm) reels, ½ reel
7" (178 mm) reels, partial reel
Revision: 27-Feb-15
Document Number: 40077
1
For technical questions, contact:
tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Analysis of concurrent execution and scheduling of RT-Thread system tasks
Introduction to RT-Thread Kernel The kernel is the most basic and important part of the operating system. The figure below is the RT-Thread kernel architecture diagram. The kernel is above the hardwar...
ID.LODA Embedded System
Remotely configure IP address, collect IO and temperature
It can remotely configure the IP address and support remote IO acquisition and dynamic temperature acquisition. It can be accessed through the domain name bjmonsoon.gicp.net[[i]This post was last edit...
bjmonsoon Microcontroller MCU
How to get CPU external frequency under DOS?
I don't see any method to get the external frequency in the CPUID instruction, but the main frequency can be obtained through RDTSC. Is there any way to get the external frequency? ? ? Thank you...
ldfsndfsa Embedded System
Can I use the dsp network port to connect a giga camera to process images?
As the title suggests, I hope you can give me some advice!...
lvyunpeng1988 DSP and ARM Processors
How to use makefsfile to convert a web page into a .h file
rtHow to convert .shtml files into .h files[[i]This post was last edited by RogerKing on 2011-5-14 20:27[/i]]...
RogerKing Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2371  82  1308  2666  826  48  2  27  54  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号