EEWORLDEEWORLDEEWORLD

Part Number

Search

2638LPA430400LI

Description
Rocker Switch, On-off-(on), Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2638LPA430400LI Overview

Rocker Switch, On-off-(on), Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2638LPA430400LI Parametric

Parameter NameAttribute value
Country Of OriginUK
ECCN codeEAR99
Is SamacsysN
YTEOL8.89
Objectid312952161
Reach Compliance CodeCompliant
End contact materialSILVER
Shell materialPOLYAMIDE
Installation featuresPANEL MOUNT
surface mountNO
Termination typeSCREW
Actuator colorBROWN
Actuator materialPOLYAMIDE
center contact materialSILVER
Actuator length0.394 inch
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
Terminal length0.437 inch
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Dielectric withstand voltage2500VRMS V
Switch typeROCKER SWITCH
Actuator typeROCKER
Contact (DC) maximum rated R load8A@24VDC
Contact functionON-OFF-(ON)
Maximum contact voltage (AC)250 V
Insulation resistance1000000000 Ω
Maximum contact current (DC)8 A
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Electrical life10000 Cycle(s)
Switch actionMOMENTARY
Minimum operating temperature-20 °C
Maximum operating temperature85 °C
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
TI live broadcast at 8pm tonight: the latest DLP products and automotive application solutions are here, interpreting dynamic ground lights and AR-HUD solutions
Want to know the latest DLP products in the market? Want to learn about the latest and innovative DLP automotive application solutions? Looking for a senior DLP engineer to familiarize you with DLP de...
nmg TI Technology Forum
About the SPI bus problem of LPC1343
About the SPI bus problem of LPC1343 I would like to ask what is the maximum SPI rate of LPC1343?...
fjr115 NXP MCU
ESP8266 fixed the bug of GPIO16 as input
The ESP8266 version has just fixed a bug, when GPIO16 is used as input, it will not be able to read the GPIO status correctly. However, GPIO16 still cannot be set to pull up....
dcexpert MicroPython Open Source section
Are the transmitting frequency 315M and the carrier frequency 38KHZ the same?
Why is the transmission frequency of some remote controls 315M, while the carrier frequency of NEC-coded remote controls is 38KHZ? Are these two concepts the same? Also, how many categories are remote...
hu柏拉图的永恒 51mcu
How to draw components on the back side of the PCB board?
I am drawing a four-layer board. The board is too small and the circuits cannot be completed. How can I draw the components on the back of the board?...
aixuexi呀呀呀呀 PCB Design
Recommended books on embedded development (Part 29) --- Embedded system development based on state machine
[align=center][size=5][b]Recommendations for high-quality books on embedded development (Twenty-nine) ---[color=#666666][font=Helvetica]Embedded system development based on state machine[/font][/color...
tiankai001 Download Centre

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2892  85  1123  1787  1002  59  2  23  36  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号