Part Number

Search

55A0811-22-9F871

Description
22 AWG 电子线,双壁 电线 19/34 白色 600V -
CategoryWire/cable    Wire and cable   
File Size34KB,2 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

55A0811-22-9F871 Online Shopping

Suppliers Part Number Price MOQ In stock  
55A0811-22-9F871 - - View Buy Now

55A0811-22-9F871 Overview

22 AWG 电子线,双壁 电线 19/34 白色 600V -

55A0811-22-9F871 Parametric

Parameter NameAttribute value
category
MakerTE Connectivity
seriesMIL-W-22759 and MIL-C-27500, 55A0811
PackageBulk
Cable type电子线,双壁
Wire gauge22 AWG
Number of wire strands19/34
conductor materialCopper, tin plated
Sheath (insulation) material乙烯-四氟乙烯共聚物(ETFE),辐射处理
Sheath (insulation) diameter0.050"(1.27mm)
Sheath (insulation) thickness0.009"(0.23mm)
length-
Voltage600V
Operating temperature-65°C ~ 150°C
Sheath colorWhite
grade-
characteristic-
Basic product number55A0811
SPECIFICATION CONTROL DRAWING
Title
SCD
55A0811
Revision
Date
WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED,
1-12-17
NORMAL WEIGHT, GENERAL PURPOSE, 600 VOLT
This specification sheet forms a part of the latest issue of Raychem Specification 55A.
AA
PRIMARY INSULATION - RADIATION-CROSSLINKED,
MODIFIED ETFE
Primary insulation shall be of a contrasting
pigmentation to that of the jacket.
CONDUCTOR - TIN-COATED COPPER
JACKET - RADIATION-CROSSLINKED,
MODIFIED ETFE
TABLE I. CONSTRUCTION DETAILS
PART
NUMBER
1/
55A0811-28-*
55A0811-26-*
55A0811-24-*
55A0811-22-*
55A0811-20-*
55A0811-18-*
55A0811-16-*
55A0811-14-*
55A0811-12-*
55A0811-10-*
55A0811-8-*
55A0811-6-*
55A0811-4-*
55A0811-2-*
55A0811-1-*
55A0811-0-*
55A0811-00-*
55A0811-000-*
55A0811-0000-*
WIRE
SIZE
(AWG)
28
26
24
22
20
18
16
14
12
10
8
6
4
2
1
0
00
000
0000
CONDUCTOR
STRANDING
(number x AWG)
7 x 36
19 x 38
19 x 36
19 x 34
19 x 32
19 x 30
19 x 29
19 x 27
37 x 28
37 x 26
133 x 29
133 x 27
133 x 25
665 x 30
817 x 30
1045 x 30
1330 x 30
1665 x 30
2109 x 30
DIAMETER OF
STRANDED
CONDUCTOR
(inch)
MINIMUM
.014
.018
.023
.029
.037
.046
.052
.065
.084
.106
.158
.198
.250
.320
.360
.395
.440
.500
.565
MAXIMUM
.016
.020
.024
.031
.039
.049
.055
.069
.089
.114
.173
.217
.274
.340
.380
.425
.475
.540
.605
FINISHED WIRE
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft.)
68.6
41.3
26.2
16.2
9.88
6.23
4.81
3.06
2.02
1.26
.701
.445
.280
.183
.149
.116
.091
.071
.056
DIAMETER
(inch)
.035 ± .002
.040 ± .002
.045 ± .002
.050 ± .002
.058 ± .002
.070 ± .003
.077 ± .003
.094 ± .003
.111 ± .003
.134 ± .004
.195 ± .008
.241 ± .010
.310 ± .010
.408 ± .012
.470 ± .012
.510 ± .016
.570 ± .016
.610 ± .016
.675 ± .022
MAXIMUM
WEIGHT
(lbs/1000 ft.)
1.30
1.70
2.30
3.20
4.70
7.20
9.00
13.8
20.5
32.4
60.3
94.5
150.
249.
325.
383.
500.
596.
753.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Raychem, TE Connectivity, TE Connectivity (logo), and TE (logo) are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-522-6752
Fax: 1-650-361-6297
© 2008-2017 Tyco Electronics Corporation. All rights reserved.
Page 1 of 2
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Some experience in compiling DSP code
I helped a colleague compile a DSP code. When I compiled it in CCS5, it said that it could not find csl.h. When I transferred it to CCS3.3, it said that the _CACHE_clean symbol was undefined, but ther...
Jacktang DSP and ARM Processors
TI Cup C Question Discussion
[align=center][b]Simple DC Electronic Load (Question C) [/b][/align][align=center][b][font=华文中宋][size=14.0pt] [Undergraduate Group] [/size][/font][/b][/align][align=left][b]1. [/b][b]Task [/b][/align]...
wengjiangang Power technology
mp3 module
I would like to ask if any of you have made or are making MP3 modules? Based on single chip microcomputer [[i] This post was last edited by guoyuanqiang on 2010-12-10 16:34 [/i]]...
guoyuanqiang MCU
RF Engineer's Reflection (Reprinted)
Netizens often ask on the Internet what knowledge an RF engineer should have and how to do RF work well. There is a discussion post about this issue that has dozens of replies, which seems to be a com...
qinkaiabc RF/Wirelessly
Use of timer
#include #include #define uint unsigned int #define uchar unsigned char sbit D1=P1^0; uchar temp,tt; uint num; uchar code table[]={0xc0,0xf9,0xa4,0xb0,0x99,0x92}; void delay(uint z ); void main() { TM...
liufengjing9 51mcu
Can the microcontroller I/O output PWM wave be directly connected to a DC motor?
As the title says, let P10 output PWM wave, and then directly connect it to one level of the DC motor and the other level to ground. Why doesn't the DC motor rotate?Is it necessary to connect an exter...
skyman_liu 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1486  1108  2321  305  930  30  23  47  7  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号