EEWORLDEEWORLDEEWORLD

Part Number

Search

M69-X2Q212-20

Description
断路器 磁性(液力延迟) 20A 277 V AC DC 拨动式开关 DIN 轨道
CategoryCircuit protection    The circuit breaker   
File Size443KB,7 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

M69-X2Q212-20 Overview

断路器 磁性(液力延迟) 20A 277 V AC DC 拨动式开关 DIN 轨道

M69-X2Q212-20 Parametric

Parameter NameAttribute value
category
MakerTE Connectivity
seriesW6
Packagetray
Installation typeDIN rail
Circuit breaker typeMagnetic (hydraulic delay)
Rated current (amps)20A
Actuator typetoggle switch
illumination-
Lighting voltage (nominal)-
Number of poles3
Rated voltage - AC277 V
Basic product numberM69
General Purpose Relays
Industrial Relays
Potter & Brumfield
W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers
n
n
n
n
n
n
Designed for the international market. UL Recognzied (UL1077 and
UL1500), CSA Accepted and VDE approved.
Ratings to 50 amps.
Heavy duty #10-32 stud connections. (W9)
Quick-connect or screw terminals. (W6)
Several delay curve options.
Trip-free operation.
Agency Approvals
UL:
Recognized as Supplementary Protector under UL 1077. Available
models meet Ignition Protection requirements in accordance with
UL1500. File E69543
CSA:
Accepted as a Supplementary Protector. File LR15734.
VDE:
Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment)
License No. 73782
Users should thoroughly review the technical data before selecting a product part number.
It is recommended that users also seek out the pertinent approvals files of the agencies/
laboratories and review them to confirm the product meets the requirements for a given
application.
Mechanical/Environmental Data
(continued)
Electrical Data
Calibration:
Breakers will hold 100% of rated current.
Breakers may trip between 101% and 124% of rated load (134% for AC/
DC units).
Breakers must trip at 125% of rated load and above (135% for AC/DC
units).
Dielectric Strength:
50/60 Hz., 1500V: DC, 1100V
Insulation Resistance:
100 Megaohms at 500VDC
Endurance:
10,000 on/off cycles - 6000 at rated load, 4000 at no load.
Units tested at six cycles per minute, 1 second on and 9 seconds off at
25°C ambient.
Typical Resistance and Impedance
Current
DC
(Amps.)
Resistance
(Ohms)
0.2
90
1.0
1.2
2.0
0.28
5.0
0.04
10.0
0.013
20.0
0.004
30.0
0.0027
40.0
0.002
50.0
0.0015
50/60
Impedance
(Ohms)
90
1.2
0.28
0.04
0.013
0.005
0.004
0.002
0.0015
Fungus and Moisture Resistance:
Special moisture resistant finish applied to all ferrous parts.
Plastic parts are made of inherently fungus resistant material.
Marking:
International “1” and “0” symbols are marked on the toggle for both W6 and
W9. W9 units have “ON” and “OFF” molded into the area at the base of the
toggle.
Mounting:
Units are mounted with two #6-32 screws from the front of the panel.
Metric models for use with M3 x 0.5 screws are available. To maintain
published performance specifications, units should not be mounted more
than 90° from their normal upright position.
Weight:
Approximately 2.5 ounces per pole.
Approvals and Ratings Table 1
W6 Series
Maximum
Voltage
65
277
277
277/480
W9 Series
Maximum
Voltage
65
277
277/480
W6 or W9 Series
Maximum
Voltage
65
250
250
415/240
W6 or W9 Series
Maximum
Voltage
48
125/250
250
UL1077/CSA (All Circuit Functions)
Current Interrupting
Frequency
Phase
Rating
Capacity
(Hz)
(Amps)
(Amps)
DC
-
0.2 - 50
2,000
50/60
1
0.2 - 20
5,000
50/60
1
21 - 50
2,500
50/60
3Ø-Wye
0.2 - 20
5,000
UL1077/CSA (All Circuit Functions)
Frequency
(Hz)
DC
50/60
50/60
Phase
-
1
3Ø-Wye
Current
Rating
(Amps)
0.2 - 50
0.2 - 50
0.2 - 20
Interrupting
Capacity
(Amps)
2,000
5,000
5,000
Tolerance: 0.1 - 4.99 ± 15%; 5 - 9.99 ± 20%; 10 - 15 ± 25%; 16 - 30 ± 50%.
VDE (Circuit Function X)
Phase
-
1
1
Current
Rating
(Amps)
0.2 - 50
0.2 - 30
31 - 50
0.2 - 30
Interrupting
Capacity
(Amps)
2,000
5,000
2,000
5,000
Mechanical/Environmental Data
Frequency
(Hz)
DC
50/60
50/60
50/60
Operating Temperature:
-40°C to +85°C.
Humidity:
Meets requirements of Mil-STD-202 method 103.
Shock:
Tested per Mil-STD-202, method 213, test condition C
(100g @ 6 ms)
Vibration:
Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06”
(1.52mm) total excursion in 2 planes.
UL1500 (Circuit Function X)
Phase
-
1
3Ø-Wye
Current
Rating
(Amps)
0.2 - 50
0.2 - 50
0.2 - 50
Interrupting
Capacity
(Amps)
3,000
1,000
1,000
Frequency
(Hz)
DC
50/60
50/60
11-2015, Rev. 1115
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1427  224  2521  1761  2531  29  5  51  36  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号