P6KE6V8(C)A - P6KE440(C)A
Transient Voltage Suppressors
P6KE6V8(C)A - P6KE440(C)A
Features
•
•
•
•
•
Glass passivated junction.
600W Peak Pulse Power capability at
1.0 ms.
Excellent clamping capability.
Low incremental surge resistance.
Fast response time; typically less
than 1.0 ps from 0 volts to BV for
unidirectional and 5.0 ns for
bidirectional.
Typical I
R
less than 1.0
µA
above 10V.
DO-15
COLOR BAND DENOTES CATHODE
ON UNIDIRECTIONAL DEVICES ONLY. NO
COLOR BAND ON BIDIRECTIONAL DEVICES.
•
DEVICES FOR BIPOLAR APPLICATIONS
- Bidirectional types use CA suffix.
- Electrical Characteristics apply in both directions.
600 Watt Transient Voltage Suppressors
Absolute Maximum Ratings*
Symbol
P
PPM
I
PPM
P
D
I
FSM
T
stg
T
J
Peak Pulse Current
Power Dissipation
.375 " lead length @ T
A
= 75°C
Non-repetitive Peak Forward Surge Current
superimposed on rated load (JEDEC method)
Storage Temperature Range
Operating Junction Temperature
T
A
= 25°C unless otherwise noted
Parameter
Peak Pulse Power Dissipation at T
P
=1ms
Value
600
see table
5.0
(Note 1)
Units
W
A
W
A
°C
°C
100
-65 to +175
+ 175
*
These ratings are limiting values above which the serviceability of any semiconductor device may be impaired.
Note 1:
Measured on 8.3 ms single half-sine wave; Duty cycle = 4 pulses per minute maximum.
2002
Fairchild Semiconductor Corporation
P6KE6V8(C)A - P6KE440(C)A, Rev. D
P6KE6V8(C)A - P6KE440(C)A
Transient Voltage Suppressors
(continued)
Electrical Characteristics
Uni-directional
Bi-directional (C)
Device
P6KE6V8(C)A
P6KE7V5(C)A
P6KE8V2(C)A
P6KE9V1(C)A
P6KE10(C)A
P6KE11(C)A
P6KE12(C)A
P6KE13(C)A
P6KE15(C)A
P6KE16(C)A
P6KE18(C)A
P6KE20(C)A
P6KE22(C)A
P6KE24(C)A
P6KE27(C)A
P6KE30(C)A
P6KE33(C)A
P6KE36(C)A
P6KE39(C)A
P6KE43(C)A
P6KE47(C)A
P6KE51(C)A
P6KE56(C)A
P6KE62(C)A
P6KE68(C)A
P6KE75(C)A
P6KE82(C)A
P6KE91(C)A
P6KE100(C)A
P6KE110(C)A
P6KE120(C)A
P6KE130(C)A
P6KE150(C)A
P6KE160(C)A
P6KE170(C)A
P6KE180(C)A
P6KE200(C)A
P6KE220(C)A
P6KE250(C)A
P6KE300(C)A
P6KE350(C)A
P6KE400(C)A
P6KE440(C)A
Reverse
Stand-off Voltage
V
RWM
(V)
5.80
6.40
7.02
7.78
8.55
9.4
10.2
11.1
12.8
13.6
15.3
17.1
18.8
20.5
23.1
25.6
28.2
30.8
33.3
36.8
40.2
43.6
47.8
53.0
58.1
64.1
70.1
77.8
85.5
94.0
102.0
111.0
128.0
136.0
145.0
154.0
171.0
185.0
214.0
256.0
300.0
342.0
376.0
T
A
= 25°C unless otherwise noted
Breakdown Voltage
V
BR
(V)
min
6.45
7.13
7.79
8.65
9.50
10.5
11.4
12.4
14.3
15.2
17.1
19.0
20.9
22.8
25.7
28.5
31.4
34.2
37.1
40.9
44.7
48.5
53.2
58.9
64.6
71.3
77.9
86.5
95.0
105.0
114.0
124.0
143.0
152.0
162.0
171.0
190.0
209.0
237.0
285.0
332.0
380.0
418.0
Max
7.14
7.88
8.61
9.55
10.5
11.6
12.6
13.7
15.8
16.8
18.9
21.0
23.1
25.2
28.4
31.5
34.7
37.8
41.0
45.2
49.4
53.6
58.8
65.1
71.4
78.8
86.1
95.5
105.0
116.0
126.0
137.0
158.0
168.0
179.0
189.0
210.0
231.0
263.0
315.0
368.0
420.0
462.0
Test
Current
I
T
(mA)
10
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Clamping Voltage
@I
PPM
V
C
(V)
10.5
11.3
12.1
13.4
14.5
15.6
16.7
18.2
21.2
22.5
25.2
27.7
30.6
33.2
37.5
41.4
45.7
49.9
53.9
59.3
64.8
70.1
77.0
85.0
92.0
103.0
113.0
125.0
137.0
152.0
165.0
179.0
207.0
219.0
234.0
246.0
274.0
328.0
344.0
414.0
482.0
548.0
602.0
Peak Pulse
Current
I
PPM
(A)
57.1
53.1
50.0
45.0
41.0
38.0
36.0
33.0
28.0
27.0
24.0
22.0
20.0
18.1
16.0
14.5
13.2
12.0
11.2
10.1
9.3
8.6
7.8
7.1
6.5
5.8
5.3
4.8
4.4
4.0
3.6
3.4
2.9
2.7
2.6
2.4
2.2
1.9
1.8
1.5
1.3
1.1
1.0
Reverse
Leakage V
RWM
I
R
(uA)*
1000
500
200
50
10
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
* For bidirectional parts with V
RWM
<10V, the I
R
max limit is doubled.
P6KE6V8(C)A - P6KE440(C)A, Rev. D
P6KE6V8(C)A - P6KE440(C)A
Transient Voltage Suppressors
(continued)
Typical Characteristics
100
100
T
A
= 25
º
C
75
Pulse Power [%]
Pulse Power [kW]
10
50
1
25
0.1
0.0001
0
0.001
0.01
0.1
Pulse Width [ms]
1
10
0
25
50
75
100 125 150
Ambient Temperature [ºC]
175
200
Figure 1. Peak Pulse Power Rating Curve
Figure 2. Pulse Derating Curve
150
tf = 10µsec
µ
Total Capacitance, C
T
[pF]
Peak Pulse Current [%]
100
Peak Value
Ippm
T
A
= 25
º
C
Pulse Width (td) is Defined
as the Point Where the Peak
Current Decays to 50% of Ipp
6000
4000
2000
1000
500
200
100
50
20
Measured at
Stand-Off
Voltage (V mw)
T
A
= 25
º
C
f = 1.0 MHz
Visg = 50m Vp-p
Measured at
Zero Bias
Half Value-Ipp
2
50
µ
10/1000µsec Waveform
as Defined by R.E.A.
td
0
e-kt
0
1
2
Time [ms]
3
4
10
1
5
10
50
Reverse Voltage, V
R
[V]
100
200
Figure 3. Pulse Waveform
Figure 4. Total Capacitance - Unidirectional
Peak Forward Surge Current, I
FSM
[A]
5
200
T
A
= T
A
max
8.3ms Single Half Sine-Wave
JEDEC Method
Power Dissipation [W]
3.75
100
2.5
50
1.25
20
0
0
25
50
75
100 125 150
Lead Temperature [ºC]
175
200
10
1
2
Figure 5. Steady State Power Derating Curve
5
10
20
Number of Cycles at 60Hz
50
100
Figure 6. Non-Repetitive Surge Current
P6KE6V8(C)A - P6KE440(C)A, Rev. D