Railway/Transportation system applications including communications systems,
information display, lighting, control systems, ticket machines, passenger
entertainment, public address systems, door control, industrial power systems and power
generation systems.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Parameter
+IN to –IN voltage
PC to –IN voltage
PR to –IN voltage
SC to –OUT voltage
–Sense to –OUT voltage
Isolation voltage
IN to OUT
IN to base
OUT to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
–0.5 to +260
–0.5 to +7.0
–0.5 to +7.0
–0.5 to +1.5
1.0
3000
1500
500
–55 to +100
–65 to +125
500 (260)
750 (390)
5 (0.57)
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
V
RMS
V
RMS
V
RMS
°C
°C
°F (°C)
°F (°C)
in-lbs (N-m)
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V110A24C400BL
V110A
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= - 10 to +100 - 20 to +125
C
= - 20 to +100 - 40 to +125
T
= - 40 to +100 - 40 to +125
H
= - 40 to +100 - 55 to +125
M
= - 55 to +100 - 65 to +125
B
Output Power
V
OUT
P
OUT
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
150W, 200W
200W, 300W
200W, 300W
300W, 400W
300W, 400W
300W, 400W
300W, 400W
300W, 400W
300W, 400W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
110V Maxi Family
Page 1 of 14
Rev 3.2
06/2017
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
54
155.5
64
56
161.7
169.4
1.3
Min
66
Typ
110
Max
154
250
65.4
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Notes
Per EN50155 and GBT-25119
<100ms
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.4
–0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 9.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20263)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.08
0.07
4.9
1.1
165
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
110V Maxi Family
Page 2 of 14
Rev 3.2
06/2017
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
6.5
(184.3)
7.4
(209.3)
100
3000
1500
500
10
7.3
(207.5)
8.2
(232.5)
115
cURus, cTÜVus, CE
8.1
(230.7)
9.0
(255.7)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
110V Maxi Family
Page 3 of 14
Rev 3.2
06/2017
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3
V
OUT
, 200W (e.g. S110A3V3C200BL, V110A3V3C200BL)
Parameter
Efficiency
S110A3V3C200BL (enhanced efficiency)
V110A3V3C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.3
81.0
4.14
Typ
86.5
82.0
90
4.3
6.1
±0.02
69.7
69.7
Max
Unit
%
113
4.46
8.2
±0.2
60.6
81.9
81.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.8
42.4
3.3
V
OUT
, 150W (e.g. S110A3V3C150BL, V110A3V3C150BL)
Parameter
Efficiency
S110A3V3C150BL (enhanced efficiency)
V110A3V3C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.0
80.5
4.14
Typ
86.0
81.8
85
4.3
6.1
±0.02
52.3
52.3
Max
Unit
%
107
4.46
7
±0.2
45.45
61.5
61.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
46.4
31.8
5
V
OUT
, 300W (e.g. S110A5C300BL, V110A5C300BL)
Parameter
Efficiency
S110A5C300BL (enhanced efficiency)
V110A5C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.2
83.0
6.03
Typ
88.1
84.9
80
6.25
12.1
±0.02
69
69
Max
Unit
%
100
6.47
13.1
±0.2
60
81
81
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.2
42
5
V
OUT
, 200W (e.g. S110A5C200BL, V110A5C200BL)
Parameter
Efficiency
S110A5C200BL (enhanced efficiency)
V110A5C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.3
84.5
6.03
Typ
88.5
85.5
166
6.25
8.3
±0.02
46
46
Max
Unit
%
208
6.47
9.7
±0.2
40
54
54
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
40.8
28
110V Maxi Family
Page 4 of 14
Rev 3.2
06/2017
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
8
V
OUT
, 300W (e.g. S110A8C300BL, V110A8C300BL)
Parameter
Efficiency
S110A8C300BL (enhanced efficiency)
V110A8C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.5
84.5
9.36
Typ
88.5
86.5
215
9.7
9
±0.02
43.1
43.1
Max
Unit
%
269
10.1
10
±0.2
37.5
50.7
50.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
38.2
26.2
8
V
OUT
, 200W (e.g. S110A8C200BL, V110A8C200BL)
Parameter
Efficiency
S110A8C200BL (enhanced efficiency)
V110A8C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
87.7
86.8
9.36
Typ
89.0
87.7
220
9.7
5.4
±0.02
28.8
28.8
Max
Unit
%
275
10.1
6.4
±0.2
25
33.8
33.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
25.5
6
12
V
OUT
, 400W (e.g. S110A12C400BL, V110A12C400BL)
Parameter
Efficiency
S110A12C400BL (enhanced efficiency)
V110A12C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.7
85.0
13.7
Typ
88.5
86.2
240
14.3
12.7
±0.02
38.3
38.3
Max
Unit
%
300
14.9
13.5
±0.2
33.33
45
45
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
33.9
23.3
12
V
OUT
, 300W (e.g. S110A12C300BL, V110A12C300BL)
Parameter
Efficiency
S110A12C300BL (enhanced efficiency)
V110A12C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.9
86.0
13.7
Typ
90.0
87.0
240
14.3
7.9
±0.02
28.8
28.8
Max
Unit
%
300
14.9
9
±0.2
25
33.8
33.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
I am now making a temperature measurement device based on Atmel sam d21. I have an Atmel sam d21 board and an extended version oled1xplained. I plan to use the DS18B20 temperature sensor to collect te...
This is a section of assembly code in STM8 motor, but after reading it, I just can't understand what it means. The low-level code is as follows:;********************* PHASE U duty cycle processing ***...
How can I write a program in Matlab to display the data file in a graphic? I know that I can use the fopen, fread, and fseek functions, but how can I draw the data in the binary file into a graphic? T...
Electronic systems are increasingly using RF sources in radio frequency (RF) applications such as automotive radar, 5G cellular, and the Internet of Things. All of these RF sources require ways to mon...
I recently used ulink2 to download programs, but an error dialog box always popped up: "cannot enter debug mode". I don't know what went wrong. I have been troubled by this for half a month. Now I can...
As more and more consumers purchase new energy vehicles, the safety of electric vehicles has become a major concern. This has been particularly prominent following a series of electric vehicle fire...[Details]
The mass production process of the new generation of cockpit platform has started, and the smart cockpit market has entered a new bonus cycle of technology iteration and platform upgrade.
...[Details]
On August 18th, Galaxis, a specialist in integrated intelligent intralogistics robotics, officially unveiled its next-generation, ultra-narrow aisle forklift mobile robot, the "VFR Ultra-Narrow Ser...[Details]
Since the beginning of this year, price wars have intensified, new models have been launched one after another, used cars with zero kilometers have become a hot topic, and the industry's internal c...[Details]
While the current industry consensus is that autonomous vehicles are robots and that their systems are managed using robotics-developed thinking, there are also cases where autonomous driving is ac...[Details]
A half-bridge is an inverter topology for converting DC to AC. A typical half-bridge circuit consists of two controller switches, a three-wire DC power supply, two feedback diodes, and two capacito...[Details]
"We have successfully launched the first version of our dedicated chip for EMB brake-by-wire. Second-generation samples have also been successfully completed, and we are actively planning a third-g...[Details]
Magna's integrated in-cabin perception system fuses vision and millimeter-wave radar data to detect the presence of passengers, identify stranded children, monitor driver fatigue and vital signs, a...[Details]
According to foreign media reports, Ford Motor has applied to the U.S. Patent and Social Security Office (USPTO) for a patent for a door anti-collision system that may be used in future Ford vehicl...[Details]
My career has been closely tied to the semiconductor industry. From product management to content marketing, I've provided countless forecasts and predictions across a variety of roles. Whethe...[Details]
MQTT Ethernet I/O modules primarily collect I/O port information and transmit data over the network. In addition to being a TCP server, Ethernet I/O modules can also function as TCP clients. Furthe...[Details]
The driving mode is not unfamiliar to vehicles. According to the driving mode of the vehicle, there are front-wheel drive, rear-wheel drive and even four-wheel drive. Four-wheel drive is a major se...[Details]
From time to time, I see some audiophiles spending a lot of money or a lot of time to DIY speakers, but the results are not what they want. Below I list some of the small experiences I summarized b...[Details]
Facial recognition, a biometric technology that uses facial features to authenticate identity, has rapidly become a global market hotspot in recent years as the technology has entered practical use...[Details]
Lithium-ion batteries are a key component of electric vehicles. Their high energy density enables them to store a large amount of energy in a relatively compact and lightweight package, which is cr...[Details]