190W Dual Output with PFC Function
■
Features :
Universal AC input / Full range
HDP-190
Built-in active PFC function
High efficiency up to 86%
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
1U low profile 36mm
Conformal coated
ZVS technology to reduce power dissipation
LED indicator for power on
3
years warranty
SPECIFICATION
MODEL
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE (max.)
RATED POWER
OUTPUT POWER (max.)
OUTPUT
HDP-190
V1
+3.8V
33A
0 ~ 40A
181.4W (typ.)
192W (max.)
V2
+2.8V
20A
0 ~ 22A
192W continue. V1 total power output shall not exceed 160W (max. 40A) ; V2 total power output shall not exceed 66W (max. 22A)
(The V1 & V2 combine total power output shall not exceed 192W)
100mVp-p
2.5 ~ 3V
±2.0%
±0.5%
±2.0%
2500ms, 50ms/115VAC at full load
16ms/115VAC at full load
127 ~ 370VDC
PF
≧
0.98/115VAC at full load
1.1A/230VAC
45A/230VAC
RIPPLE & NOISE (max.)
Note.2
100mVp-p
VOLTAGE ADJ. RANGE
Note.6
3.6 ~ 4V
VOLTAGE TOLERANCE
Note.3
±2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
±0.5%
±2.0%
1000ms, 50ms/230VAC
16ms/230VAC
Note.5
90 ~ 264VAC
VOLTAGE RANGE
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
PF
≧
0.94/230VAC
86%
2.7A/115VAC
30A/115VAC
<0.7mA / 240VAC
V1+V2: 105 ~ 150% max. output power ; or V2: 125 ~ 170% rated current
Protection type: Hiccup mode, recovers automatically after fault condition is removed
V2: 3.22 ~ 3.78V
V1: 4.37 ~ 5.13V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recovery
-30 ~ +70
℃
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
-40 ~ +85
℃
, 10 ~ 95% RH
TEMP. COEFFICIENT
±
0.03%/
℃
(0 ~ 50
℃
)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
NOTE
UL60950-1, TUV EN60950-1, CCC GB4943.1 approved
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
℃
/ 70% RH
Compliance to EN55022 (CISPR22), GB9254, class B, EN61000-3-2,-3, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2,
heavy industry level, criteria A
111.3K hrs min.
MIL-HDBK-217F (25
℃
)
215*115*36mm (L*W*H)
0.95Kg; 15pcs/15.3Kg/0.7CUFT
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Output voltage between V1 and V2 should be higher than 1.0V(V1-V2
≧
1.0V).
File Name:HDP-190-SPEC 2015-02-28