Part Number

Search

GLC75-15G

Description
Switching Power Supplies 75W 15V @ 5A
CategoryPower/power management    The power supply circuit   
File Size199KB,2 Pages
ManufacturerSL Power
Download Datasheet Parametric Compare View All

GLC75-15G Online Shopping

Suppliers Part Number Price MOQ In stock  
GLC75-15G - - View Buy Now

GLC75-15G Overview

Switching Power Supplies 75W 15V @ 5A

GLC75-15G Parametric

Parameter NameAttribute value
MakerSL Power
package instruction,
Reach Compliance Codeunknown
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
CertificationCE, CSA, EN, IEC, UL
high39.7 mm
Maximum input voltage264 V
Minimum input voltage90 V
length146.05 mm
Maximum operating temperature50 °C
Minimum operating temperature
Maximum output current7.7 A
Nominal output voltage15 V
ProtectOUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE
Ripple voltage (main output)0.05303 Vrms
Maximum total power output75 W
width86.36 mm
GLC75 Commercial/GLM75
Medical
75 Watt Single Output Global Performance Switchers
FEATURES:
Cost-effective single-output power source
3.4" x 5.75" x 1.56" (meets 1U applications)
Universal input 90-264 Vac
2-year warranty
Complies with EN61000-3-2 Class A
Also available in multiple output versions
Conducted EMI exceeds FCC Class B and CISPR 22
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
• Commercial Approved to UL1950, CSA22.2 No. 234
and IEC950, EN60950
• Medical Approved to UL2601-1, IEC601-1 and
CSA22.2 No. 601
marked to LVD
Inrush Current
Inrush limited by internal thermistors. Inrush at 240 Vac,
averaged over the first ac half-cycle under cold start
conditions will not exceed 37 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
Power Fail
A standard TTL or CMOS compatible output goes low
(< 0.5 V) 5ms before output voltage drops more than 4%
below nominal voltage upon loss of ac power. Signal is
factory set to trip on 84 to 94 Vac brown-out depending
upon incoming line impedance and distortion. Other
settings are available through adjustment of built-in
potentiometer (consult factory for assistance). Output will
stay low for 20 ms minimum.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the
following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions GLC75
Conducted Emissions GLM75
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Line Frequency Harmonics
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN55011 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-3-2 Class A
SPECIFICATIONS:
Ac Input
90-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated
output load not to exceed 2.3 A.
Output Power
Normal continuous output power is 75 W for unrestricted
natural convection cooling; 110 W with 26 cfm airflow.
Output Regulation
Regulation measured by changing from 5% to 50% load
or 50% load to full load in either direction.
Overload Protection
Factory set to begin power limiting at approximately 120
W (GLC 75-5 is set at approximately 100 W). Fully
protected against short circuit and output overload. Short
circuit protection is cycling type power limit.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
mode. Measured with noise probe directly across output
terminals of the power supply.
Transient Response
Main Output: 500 µs typical response time for return to
within 0.5% of final value for a 50% load step change,
∆i/
∆t<0.2
A/µs. Maximum voltage deviation is 3.5%. Startup/
shutdown overshoot less than 3%.
Overvoltage Protection
Standard on all models.
Voltage Adjust
Factory set on standard unit; however, potentiometer
adjusts voltage ±5% minimum. Consult factory for
application assistance.
Efficiency
72-85% depending on model.
Input Protection
Internal ac fuse provided. Designed to blow only if a
catastrophic failure occurs in the unit—fuse does not blow
on overload or short circuit.
Commercial Safety
All GLC models are approved to UL1950, CSA22.2 No.
234 Level 3, IEC950 and EN60950. Consult factory for
approval status.
Medical Leakage Current
70 µA 264 V @ 50 Hz (normal conditions).
Medical Safety
All GLM models are approved to UL2601-1, CSA-C22.2
No. 601.1, IEC601-1 and EN60601-1. Consult factory for
approval status.
40
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com

GLC75-15G Related Products

GLC75-15G GLM75B GLM75-12 GLC75-5 GLM75-15 GLM75-24 GLM75-15G GLM75J GLC75-12G
Description Switching Power Supplies 75W 15V @ 5A Switching Power Supplies 75W 12V 6.3A Switching Power Supplies 75W 5.1V @ 13.7A Switching Power Supplies 75W 15V 5A Switching Power Supplies 75W 24V 3.1A Switching Power Supplies 75W 15V 5A Switching Power Supplies 75W +5.1/+12/-12/5V Switching Power Supplies 75W 12V @ 6.3A
Product Category - Switching Power Supplies Switching Power Supplies Switching Power Supplies Switching Power Supplies Switching Power Supplies - Switching Power Supplies Switching Power Supplies
Manufacturer - SL Power SL Power SL Power SL Power SL Power - SL Power SL Power
RoHS - No No No No No - No Details
Product - Switching Supplies Switching Supplies Switching Supplies Switching Supplies Switching Supplies - Switching Supplies Switching Supplies
Output Voltage-Channel 1 - 5.1 VDC 12 V 5.1 VDC 15 VDC 24 VDC - 5.1 VDC 12 V
Number of Outputs - 4 Output 1 Output 1 Output 1 Output 1 Output - 4 Output 1 Output
Output Power - 75 W 75 W 75 W 75 W 75 W - 75 W 75 W
Open Frame/Enclosed - Open Frame Open Frame Open Frame Open Frame Open Frame - Open Frame Open Frame
Input Voltage - 90 VAC to 264 VAC 90 VAC to 264 VAC 90 VAC to 264 VAC 90 VAC to 264 VAC 90 VAC to 264 VAC - 90 VAC to 264 VAC 90 VAC to 264 VAC
Output Current-Channel 1 - 8 A 6.3 A 13.7 A 5 A 3.1 A - 8 A 6.3 A
Commercial/Medical - Medical Medical Commercial Medical Medical - Medical Commercial
Mounting Style - Chassis Chassis Chassis Chassis Chassis - Chassis Chassis
Length - 7 in 5.75 in 5.75 in 5.75 in 5.75 in - 7 in 5.75 in
Width - 4.25 in 3.4 in 3.4 in 3.4 in 3.4 in - 4.25 in 3.4 in
Height - 1.3 in 1.56 in 1.56 in 1.56 in 1.56 in - 1.3 in 1.56 in
Approvals - EN60601-1, UL60601-1 EN60601-1, UL60601-1 EN60950-1, UL60950-1 EN60601-1, UL60601-1 EN60601-1, UL60601-1 - EN60601-1, UL60601-1 EN60950-1, UL60950-1
Cooling Method - Convection, Air-Cooled Convection, Air-Cooled Convection, Air-Cooled Convection, Air-Cooled Convection, Air-Cooled - Convection, Air-Cooled Convection, Air-Cooled
Input Voltage, Max - 264 VAC 264 VAC 264 VAC 264 VAC 264 VAC - 264 VAC 264 VAC
Input Voltage, Min - 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC - 90 VAC 90 VAC
Load Regulation - Regulated Regulated Regulated Regulated Regulated - Regulated Regulated
Mechanical Style - Open / Enclosed Frame Open / Enclosed Frame Open / Enclosed Frame Open / Enclosed Frame Open / Enclosed Frame - Open / Enclosed Frame Open / Enclosed Frame
Operating Temperature Range - 0 C to + 50 C 0 C to + 50 C 0 C to + 50 C 0 C to + 50 C 0 C to + 50 C - 0 C to + 50 C 0 C to + 50 C
Output Voltage V1, Nominal - 5.1 VDC 12 VDC 5.1 VDC 15 VDC 24 VDC - 5.1 VDC 12 VDC
Factory Pack Quantity - 15 15 15 15 15 - - 1
Unit Weight - - 1 lb 1 lb 1 lb 1 lb - - 1 lb
Definition and Difference between DSP Devices and General-Purpose Processors (GPP)
Consider an example of digital signal processing, such as a finite impulse response filter (FIR). In mathematical terms, a FIR filter is a series of dot products. It takes an input quantity and an ord...
fish001 DSP and ARM Processors
When running the human-computer interaction demonstration program of MSP430G2553, why does the HyperTerminal always show that the COM port cannot be opened?
When running the human-computer interaction demonstration program of MSP430G2553, why does the HyperTerminal always show that the COM port cannot be opened?...
易爆炸弹 Microcontroller MCU
How to use the DE1-SoC GPIO interface
I am a beginner in FPGA and I use DE1-SoC to implement a small traffic light program. Modelsim simulation has no problems. The program output includes two parts, one is the countdown displayed by the ...
ASHERkang FPGA/CPLD
Ask for advice... Using the mid-circuit drive ultrasonic circuit
As shown in the circuit diagram below, this is a transceiver. I would like to ask you all, now I only want to use the sending part. 1. Is it possible to intercept the circuit in this way? Is there any...
1013850890 Analog electronics
Calculation of energy storage inductance of reverse series switching power supply Principle and design of switching power supply (Part 6)
[b]1-3-2. Calculation of energy storage inductance of reverse series switching power supply[/b] The calculation method of energy storage inductance of reverse series switching power supply is basicall...
noyisi112 Power technology
Urgent help! Measure the oil pressure sensor inside the hydraulic pipeline
Our factory has a hydraulic system. The oil pipeline is 3 cm in diameter. The pipeline is very valuable and cannot be disconnected in the middle (that is, there is no chance of contact with the hydrau...
yyxlh999 Sensor

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2539  1536  1227  118  850  52  31  25  3  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号