Industrial Pressure Sensors FEMA
CategoryThe sensor   
File Size410KB,20 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

DCMV6 Online Shopping

Suppliers Part Number Price MOQ In stock  
DCMV6 - - View Buy Now

DCMV6 Overview

Industrial Pressure Sensors FEMA

DCMV6 Parametric

Parameter NameAttribute value
Product CategoryIndustrial Pressure Sensors
ManufacturerHoneywell
ProductPressure Switches
Operating Pressure0.5 bar to 6 bar
Pressure TypeDifferential
Accuracy< 1 %
Port SizeG 1/2, G 1/4
Operating Supply Voltage250 VAC
Maximum Operating Temperature+ 70 C
Minimum Operating Temperature- 25 C
Mounting StylePanel
Operating Supply Current8 A
PackagingBulk
Pressure PortPort
Factory Pack Quantity1
40
Mechanical pressure switches
Liquids and gases
DCM/DNM
Pressure switches and pressure monitors for overpressure
This universal pressure switch can be used in
general mechanical engineering and the printing
machine industry, as well as in pneumatics and
hydraulics.
SIL 2 according IEC 61508-2
DCM25
Technical data
Pressure connection
External thread G 1/2 (pressure gauge
connection) according to DIN 16 288 and inter-
nal thread G 1/4 according to ISO 228 Part 1.
Switching device
Robust housing (200) made of seawater-
resistant diecast aluminium GD Al Si 12.
Protection class
IP 54, in vertical position.
Pressure sensor materials
DNM025…DCM63 Metal bellows: 1.4571
Sensor housing: 1.4104
DCM025 – DCM 1 Metal bellows: Cu Sensor
housing: Cu + Ms
DCM4016/
Diaphragm: Perbunan
DCM4025
Sensor housing: 1.4301
DCM1000
Diaphragm: Perbunan
Sensor housing: Brass
Mounting position
Vertically upright and horizontal. DCM4016
and 4025 vertically upright.
Ambient temp. at switching device
–25…+70 °C, except: DCM4016,
4025, 1000: –15…+60 °C
Max. medium temperature
The maximum medium temperature at the
pressure sensor must not exceed the
permitted ambient temperature at the
switching device. Temperatures may reach
85°C for short periods). Higher medium
temperatures are possible provided the above
limit values for the switching device are
ensured by suitable measures (e.g. siphon).
Mounting
Directly on the pressure line (pressure
gaugeconnection) or on a flat surface with two
4 mm Ø screws.
Switching pressure
Adjustable from outside with screwdriver.
Switching differential
Not adjustable with DCM and types. Adjustable
from outside with DCMV types. For values see
Product Summary.
Contact arrangement
Single-pole changeover switch.
Switching
capacity
Normal
250 VAC 250 VDC 24 VDC
(ohm) (ind) (ohm) (ohm)
8A 5A
0.3 A
8A
Type
Setting range
Switching
Max.
Materials in- Dimen-
differential
permissible contact with sioned
(mean values) pressure
medium
drawing
page 25 + 26
1 + 11
1 + 10
1 + 14
1 + 15
1 + 12
Sensor
housing
1.4104
+
Pressure
bellow
1.4571
1 + 18
1 + 17
Switching differential not adjustable
DCM4016
1…16 mbar
2
DCM4025
4…25 mbar
2
DCM1000
10…100 mbar
12
DCM025
0.04…0.25 bar
0.03
DCM06
0.1…0,6 bar
0.04
DCM1
0.2…1,6 bar
0.04
DNM025
0.04…0.25 bar
0.03
DCM506
15…60 mbar
10
DCM3
0.2…2.5 bar
0.1
DCM6
0.5…6 bar
0.15
DCM625
0.5…6 bar
0.25
DCM10
1…10 bar
0,3
DCM16
3…16 bar
0.5
DCM25
4…25 bar
1.0
DCM40
8…40 bar
1.3
DCM63
16…63 bar
2.0
mbar 1
mbar 1
mbar 10
bar
6
bar
6
bar
6
bar
6
mbar 12
bar 16
bar 16
bar 25
bar 25
bar 25
bar 60
bar 60
bar 130
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
Perbunan
+ 1.4301
Perbunan + MS
Cu + Ms
Cu + Ms
Cu + Ms
1 + 16
Switching differential adjustable
DCMV025
0.04…0.25 bar
0.03…0.4 bar
DCMV06
0.1…0.6 bar
0.04…0.5 bar
DCMV1
0.2…1.6 bar 0.07…0.55 bar
DCMV3
0.2…2.5 bar
0.15…1.5 bar
DCMV6
0.5…6 bar
0.25…2.0 bar
DCMV625
0.5…6 bar
0.25…2.0 bar
DCMV10
1…10 bar
0.5…2.8 bar
DCMV16
3…16 bar
0.7…3.5 bar
DCMV25
4…25 bar
1.3…6.0 bar
DCMV40
8…40 bar
2.6…6.6 bar
DCMV63
16…63 bar
3.0…10 bar
6
6
6
16
16
25
25
25
60
60
130
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
Cu + Ms
Sensor
housing
1.4104
+
Pressure
bellow
1.4571
1 + 14
1 + 18
1 + 17
1 + 16
For smaller pressure ranges see also VCM, DGM, HCD and DPS sheets.
For additional functions refer page 30 – 32.
Calibration
The
DCM
series is calibrated for falling pressure. This means that the adjustable switching pressure on
the scale corresponds to the switching point at falling pressure. The reset point is higher by the amount
of the switching differential. (See also page 27, 1. Calibration at lower switching point).
-DCM/DNM
see page 65
s
Protection Class:
IP 54
Methods of programming interrupts in uCOS-II
The platform is LPC1768, and uCOS is running on it. I started the RTC of LPC1768, and want to enter an interrupt when the RTC clock changes. How can I write it? Is there a sample program?...
578391555 Real-time operating system RTOS
ST MEMS Creative Competition Post 3 - Learning and Application of Six-axis Sensor LSM6DSOX
[i=s]This post was last edited by a media student on 2020-5-6 22:57[/i]ST MEMS Creative Competition Post 3 - Learning and Application of Six-axis Sensor LSM6DSOX I will take advantage of the May Day h...
传媒学子 ST MEMS Sensor Creative Design Competition
How to get the size of the phone screen
I am using C# to develop a mobile client. When I am making the interface, how can I obtain the size of the phone's hardware screen so that certain interfaces can be displayed in the center?...
lpasmg Embedded System
Watch TE Sensors videos in the TE Webinar Learning Center
The sensor channel of TE Webinar Learning Center summarizes the selection and latest application cases of temperature, pressure, humidity, composite, wireless, and medical sensors in the fields of Int...
zqy1111 Robotics Development
Looking for a part-time job to send and receive short messages on a Dopod phone, the server receives and parses and sends short messages to the PDA
Looking for a part-time job to send and receive short messages on a Dopod mobile phone, the server receives and parses short messages and sends short messages to the PDA. The PDA operating system is W...
毅通客服1 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2082  952  832  1892  902  42  20  17  39  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号