EEWORLDEEWORLDEEWORLD

Part Number

Search

ZUS101205-G

Description
Isolated DC/DC Converters 10W 5V 2A Through Hole
Categorysemiconductor    Power management   
File Size498KB,13 Pages
ManufacturerCosel
Download Datasheet Parametric View All

ZUS101205-G Online Shopping

Suppliers Part Number Price MOQ In stock  
ZUS101205-G - - View Buy Now

ZUS101205-G Overview

Isolated DC/DC Converters 10W 5V 2A Through Hole

ZUS101205-G Parametric

Parameter NameAttribute value
Product CategoryIsolated DC/DC Converters
ManufacturerCosel
RoHSDetails
Number of Outputs1 Output
Output Power10 W
Input Voltage9 V to 18 V
Output Voltage-Channel 15 V
Output Current-Channel 12 A
Isolation Voltage500 V
Mounting StyleThrough Hole
Length1.77 in
Width1.38 in
Height0.28 in
Commercial/MedicalCommercial
Operating Temperature Range- 20 C to + 71 C
ProductIsolated
Factory Pack Quantity250
Unit Weight1.410958 oz
DC-DC Converters PCB Mount type
Ordering information
ZUS1R5
R
ZU
1
2
S
1R5
3
4
12
5
05
1Series
name
2Single
output
3Output
wattage
4Input
voltage
5Output
voltage
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
ZUS1R50505
1.50
VOLTAGE[V] 5
CURRENT[A] 0.30
ZUS1R50512
1.56
12
0.13
ZUS1R50515
1.50
15
0.10
ZUS1R51205
1.50
5
0.30
ZUS1R51212
1.56
12
0.13
ZUS1R51215
1.50
15
0.10
ZUS1R52405
1.50
5
0.30
ZUS1R52412
1.56
12
0.13
ZUS1R52415
1.50
15
0.10
ZUS1R54805
1.50
5
0.30
ZUS1R54812
1.56
12
0.13
ZUS1R54815
1.50
15
0.10
SPECIFICATIONS
MODEL
VOLTAGE[V]
*
1
CURRENT[A]
INPUT
*
1
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*
2
RIPPLE[mVp-p]
OUTPUT
RIPPLE NOISE[mVp-p]
*
2
TEMPERATURE REGULATION[mV] -20 to +55
C
*
3
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
PROTECTION
OVERCURRENT PROTECTION
CIRCUIT
INPUT-OUTPUT
ISOLATION INPUT-CASE
OUTPUT-CASE
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
SAFETY
AGENCY APPROVALS
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
*1
*2
*3
*
ZU/ZT
ZUS1R50505 ZUS1R50512 ZUS1R50515 ZUS1R51205 ZUS1R51212 ZUS1R51215 ZUS1R52405 ZUS1R52412 ZUS1R52415 ZUS1R54805 ZUS1R54812
DC4.5 - 9
DC9 - 18
DC18 - 36
DC36 - 72
0.441typ 0.459typ 0.441typ 0.176typ 0.183typ 0.176typ 0.088typ 0.092typ 0.088typ 0.043typ 0.045typ
68typ
68typ
68typ
71typ
71typ
71typ
71typ
71typ
71typ
73typ
73typ
5
12
15
5
12
15
5
12
15
5
12
0.30
0.13
0.10
0.30
0.13
0.10
0.30
0.13
0.10
0.30
0.13
20max 48max 60max 20max 48max 60max 20max 48max 60max 20max 48max
40max 100max 120max 40max 100max 120max 40max 100max 120max 40max 100max
80max 120max 120max 80max 120max 120max 80max 120max 120max 80max 120max
120max 150max 150max 120max 150max 150max 120max 150max 150max 120max 150max
50max 150max 180max 50max 150max 180max 50max 150max 180max 50max 150max
20max 48max 60max 20max 48max 60max 20max 48max 60max 20max 48max
20max (Minimum input, Io=100%)
Fixed
4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60
Works over 105% of rating and recovers automatically
AC500V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (20
t
15
C
)
AC500V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (20
t
15
C
)
AC500V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (20
t
15
C
)
-20 to +71
C
, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet)
-40 to +85
C
, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s
2
(10G), 3minutes period, 60minutes each along X, Y and Z axis
490.3m/s
2
(50G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with IEC60950-1
27.5
X
7
X
18mm (W
X
H
X
D) / 10g max
Convection
ZUS1R54815
0.043typ
73typ
15
0.10
60max
120max
120max
150max
180max
60max
14.25 - 15.75
max
Rated input 5V, 12V, 24V or 48V DC Io=100%.
Measured by 20MHz oscilloscope.
The drift is a change at 25C of ambient temperature and 30 minutes - 8 hours after the input voltage applied at rated input/output.
Series/Parallel operation with other model is not possible.
ZU/ZT-2
Wolverine Kit Coming Soon
This is the guy. This is what Wolverine looked like when he first appeared. I guess he will still appear in a mode compatible with the launchpad series. It is estimated that the ink screen will be rel...
wstt Microcontroller MCU
[Reprint] Submarine cables: the unsung heroes behind the Internet
The cables lying on the cold seabed transmit 99% of the Internet data. They are reliable, fast and widely used, making transoceanic communications possible in an instant, ensuring international trade ...
chenzhufly Integrated technical exchanges
Some suggestions for forum settings
1. It is recommended to use topic classification (the topic classification names must be carefully defined and the number must be appropriate), and set that posts must be classified; 2. It is recommen...
adqin Suggestions & Announcements
Driving LCD12232 C language source code
Passed verification under keil2...
ben007sky2003 MCU
Button control LEI water light
[i=s] This post was last edited by lgl80238023 on 2014-11-21 22:36 [/i] Hi guys, I wrote a program to control the flow direction of LEDs with buttons. If I press the buttons in the normal order, the f...
lgl80238023 FPGA/CPLD
Purgatory Legend-ROM War
[align=left]In the previous course, we have learned about the phase-locked loop. Next, let’s learn how to use another IP core - the on-chip memory ROM. [/align][align=left]First, create a new project[...
梦翼师兄 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 126  2239  171  1580  2426  3  46  4  32  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号