Datasheet
Power line filter
for shielded rooms & secure area
250/277/480 V, 50/60 Hz, 1--100 A, 40
°C
Ordering code:
Date:
Version:
B84299D6***A(B)00*
2011--07--22
06
©
EPCOS AG 2011. Reproduction, publication and dissemination of this publication, enclosures
hereto and the information contained therein without EPCOS’ prior express consent is prohibited.
Page 1 of 10
Power line filter
for shielded rooms & secure area
B84299D6***A(B)00*
Technical data and measuring conditions
Rated frequency
Rated temperature
Overload capability (thermal)
for 3 min per hour or
for 30 s per hour
Climatic category (IEC 60068--1)
Rated frequency
B84299D60*0B003
-- Rated voltage
Test voltage line to line for 2 s
Test voltage line to case for 2 s
B84299D6300B000
-- Rated voltage
Test voltage line to line for 2 s
Test voltage line to case for 2 s
B84299D6*00B003
-- Rated voltage
Test voltage line to line for 2 s
Test voltage line to case for 2 s
B84299D6101A003
-- Rated voltage
Test voltage line to line for 2 s
Test voltage line to case for 2 s
Characteristics and ordering codes
I
R
LINE
terminals:
threaded
studs
#6--32 UNC 2A
#6--32 UNC 2A
f
R
T
R
50/60
40
1.5 x I
R
2.5 x I
R
25/85/21
Hz
°C
f
R
Ur
U
test
U
test
Ur
U
test
U
test
Ur
U
test
U
test
Ur
U
test
U
test
50/60
250
1768
2121
250
1768
2121
480
2158
2200
277
2158
2200
Hz
V AC
V DC
V DC
V AC
V DC
V DC
V AC
V DC
V DC
V AC
V DC
V DC
LOAD
terminals:
cabels
I
leak 2)
R
typ
Approx.
weight
kg
1.9
1.9
1.5
10.8
22
11.5
Ordering code
Approvals for
USA, Canada:
UL (listed)
cUL (listed)
x
x
x
x
x
x
A
1
5
30
30
60
100
AWG 18
AWG 18
AWG 12
AWG 10
AWG 6
AWG 2
mA
1.6
1.6
157
1706
1714
3751
m
107
107
3.2
7.7
6
3
B84299D6010B003
B84299D6050B003
B84299D6300B000
B84299D6300B003
B84299D6600B003
B84299D6101A003
M6
M6
M8
M10
2) Calculation according draft proposal IEC 60939- Ed. 3 (2008- -29), annex A, ”Calculation of leakage current” at 50Hz.
-1
-10-
3)
X
= approval granted
P
= pending
D
= design complies with
-
= none
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 2 of 10
B84299-- D6*-- A(B)*-- 06-- 7659
Power line filter
for shielded rooms & secure area
B84299D6***A(B)00*
Circuit diagram for B84299D6010B003 and B84299D6050B003
LINE
L
L’
LOAD
N
N’
Circuit diagram for B84299D6300B000
LINE
L
L’
LOAD
N
N’
Circuit diagram for B84299D6300B003
LINE
LOAD
L1
L1’
L2
L2’
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 3 of 10
B84299-- D6*-- A(B)*-- 06-- 7659
Power line filter
for shielded rooms & secure area
B84299D6***A(B)00*
Circuit Diagram for B84299D6600B003
LINE
LOAD
L1
L1’
L2
L2’
Circuit Diagram for B84299D6101A003
LINE
LOAD
L
L’
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 4 of 10
B84299-- D6*-- A(B)*-- 06-- 7659
Power line filter
for shielded rooms & secure area
B84299D6***A(B)00*
Dimensions for B84299D6010B003, B84299D6050B003
60 #0.1
20
15
230
25
63
89
Beschriftung
20.6
M4
20 #5 39.8
+10
30
+10
450
3x Litze/ Litz wire
AWG18
24
M25x1,5
79
All dimensions are in mm.
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 5 of 10
B84299-- D6*-- A(B)*-- 06-- 7659
10
30