Packard Electric Metri-Pack 150 Series, 12” 20” AWG leads
1/4-18 NPT (external), 3/8-24 UNF-2A (male) *
1
303 Stainless Steel
0.5 - 4.5 VDC
Attributes
▀
▀
▀
▀
▀
▀
▀
▀
▀
▀
Typical Applications
▀
▀
▀
▀
▀
▀
▀
▀
▀
Dry Media *
2
Superior Long Term Stability
Excellent Repeatability/Hysteresis
Superior EMI/RFI Rejection
Low Power Consumption
Linear Output
Temperature Compensated
Over-Voltage, Reverse Polarity & Short Circuit Protection
Ten Million Cycle Life Expectancy
Outstanding Shock & Vibration Performance
Steam Sterilizers
Gasoline & Diesel Engines
Natural Gas & CNG Engines
Agricultural Chemical Equipment
Level Measurement
Test Equipment
Injection Molding
Coolant Pressure
Industrial Compressors
2. For wet conductive media please contact us
Description
The model P265 is based on Kavlico’s field proven ceramic capacitive technology with the latest state-of-the-art
ASIC. Featuring a 303SS housing, the P265 is designed for general use wherever a rugged and reliable pressure
transducer is required. The P265 package has a built-in MetriPack 150, electrical connector and supports
popular process connection threads. The P265 is offered with a variety of seal materials and is suitable for many
diverse applications. Specifically intended for OEM applications, the P265 delivers a cost effective solution
without compromising performance or reliability.
www.kavlico.com
Technical Specifications
Pressure Ranges
From 0 to …
PSIA,
PSIG, 1 5
PSIS
PSIA, 75
PSIG,
PSIS
PSIA, 1000
PSIG,
PSIS
20
100
30
150
50
250
75
375
100
300
150
450
200
600
300
900
500
1500
750
1500
1000
2000
Proof pressure
1000
1000
1000
1000
2000
2000
2000
2000
2000
2000
2000
Burst pressure
Physical
Operating Life Cycle
Vibration Resistance
Shock Resistance
Drop Test
Weight
Ingress Protection
Operating Temperature
Storage Temperature
Media
2. for more details see How to Order
min. 10 million full pressure cycles over the full range
10 G’s peak to peak sinusoidal (10 to 2000 Hz)
75 G’s ½ sinewave
1 meter drop on concrete as per SAE J1455 / DIN EN 60068-2-3-1
≤
100 grams (without mating connector)
IP 65 or IP67 - depending on electrical connector
-40°C to 125°C (depending on seal material) *
2
-40°C to 125°C (depending on seal material) *
2
All class II fluids and gases compatible with stainless steel 303 and the internal seal
ring material
Performance
Total error band *
3
Stability coefficient
Temp. Coefficients - Zero
Temp. Coefficients - Span
+/-2% of span (-20
≤
T
≤
100° C) +/-3% of span (T < -20° C,T < 100° C)
+/-0.5 % of full span over 1 year
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
3. Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in vertical mounting position with pressure port down
www.kavlico.com
Data Sheet P265
2
Electrical
Output Signal
Operating Supply Signal
Power Consumption
Overvoltage Protection
Short-circuit Proofness
Insulation Voltage
Reverse Polarity Protection
Load
Response Time
4. for min. 3 intervals at 5 minutes each
5. for min. 10 seconds on assigned pins
0.5…4.5 VDC Ratiometric
5 VDC ± 10%
≤
25 mW
16 VDC
Yes
*4
500 VDC
Yes *
5
≥
25 kΩ
15 ms max. to 63% of full scale pressure with step change on input
Approvals & Certificates
ROHS
2011/65/EU ROHS Directive
www.kavlico.com
Data Sheet P265
3
Dimensions
Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range, design and specific measuring
conditions. Non-compliance can result in serious injury and/or damage to the equipment.
Warning:
The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form
of contractual commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular
use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable
for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification,
addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance)
which has not been expressly agreed by us prior to the sale of our products.
www.kavlico.com
Data Sheet P265
4
How to Order
Seal Material
B Nitrile
C Neoprene
D Fluorocarbon
E Fluorosilicone
F Ethylene Propylene
Pressure Connection (port)
1 1/4 - 18 NPT (External Threads)
2 3/8 - 24 UNF-2A (Male)
3 3/8 - 24 UNF-2B (Female)
4 1/8 - 27 NPT
P265
500
S
Reference
A Absolute
G Gage
S Sealed Gage
F
1
A
Pressure Ranges
0 - 15 PSI
15
0 - 20 PSI
0 - 30 PSI
0 - 50 PSI
0 - 75 PSI
0 - 100 PSI
0 - 150 PSI
0 - 200 PSI
0 - 300 PSI
0 - 500 PSI
0 - 750 PSI
0 - 1000 PSI
20
30
50
75
100
150
200
300
500
750
1000
Built-in Electrical Connection
A Packard with Mating Connector
B 12”, 18 AWG Leads
C Packard without Mating Connector
Example:
P265-500-S-F-1-A
Description:
P265 Pressure Transmiter, 0-500 PSIS (Sealed Gage), with Ethylene Propylene Seal Material, 1/4 - 18 NPT
Pressure Connection and Mating Connector
Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range, design and specific measuring
conditions. Non-compliance can result in serious injury and/or damage to the equipment.
Warning:
The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any
form of contractual commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over any
particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product
is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any
modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or
substance) which has not been expressly agreed by us prior to the sale of our products.
ARM Development and Debugging Tutorial Hardware Part 1: Overall architecture of the development board The development board I designed is based on the Samsung 44B0 demo board, with reference to releva...
The crystal oscillator of the microcontroller generally uses a 2-pin straight-plug crystal oscillator. Suddenly, I wonder if a passive crystal oscillator with the same frequency can be directly replac...
I have a small question here. I usually only apply it, but I haven't analyzed it carefully. Now I suddenly feel a little confused. The book says that the threshold voltage of diode conduction is about...
[flash]http://player.youku.com/player.php/sid/XMjI4Mjk4MDQ0/v.swf[/flash] Some components could not be found, which delayed the progress! Let's put the pictures first...
[i=s] This post was last edited by littleshrimp on 2017-8-21 19:16 [/i] Support -270 degrees Celsius to +1372 degrees Celsius test using ADS1263, using ADS1263 internal temperature sensor for cold jun...
The rapid development of the Internet has realized high-speed information transmission and resource sharing, greatly facilitating people's lives. Embedded systems are widely used in various electr...[Details]
In early 2002, I started to write a working program for an IC card prepaid electricity meter. The meter used Philips' 8-bit 51-expanded single-chip microcomputer
87LPC764
, and wa...[Details]
1. Introduction
RFID (radio frequency identification) is a non-contact automatic identification technology that emerged in the 1990s. It uses the characteristics of radio frequency signal prop...[Details]
In
circuit design,
current
measurement
is widely used, and the main fields are divided into three categories: in measurement,
the electric meter
is used to measure the curre...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
introduction
Solar cells and LED lighting are typical applications of new energy and energy-saving and efficient technologies. Solar LED lighting uses solar cells to convert solar energy...[Details]
Electronic systems are located at different points on the automotive power bus and therefore often need to operate under very stringent power requirements. These include load dump, cold crank, very lo...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
My colleague and I spent the day chatting in the hotel bar. We had met with several customers. We were both wondering how come these engineers we were meeting knew almost nothing about analog techn...[Details]
0 Introduction
With the development of society, people pay more and more attention to security work. Monitoring products have been used in various fields instead of being used only in importan...[Details]
5. Identifiers and keywords of C language
A complete PIC microcontroller C language program usually consists of six parts: include files (i.e. header files 1, variable definitions, variable de...[Details]
1 Introduction
Building Automation System (BAS) is a distributed monitoring system (DCS) designed according to distributed information and control theory. It is the result of the mutual de...[Details]
1 Introduction
With the development of control, computer, communication, network technology, etc., a new control technology, namely fieldbus, has emerged in the field of industrial control...[Details]
1. Introduction
Testing the temperature of steel billets before rolling is an important measure to ensure the quality of steel. Traditional manual testing is difficult to ensure product qu...[Details]
In the analysis of electronic circuits, static analysis (also known as DC analysis) is the basis of circuit analysis. However, it is well known that electronic components are nonlinear, so the anal...[Details]