Industrial and process control, distributed power, medical, ATE, communications, defense
and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V24A12T400BL2
24A
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= - 10 to +100 - 20 to +125
C
= - 20 to +100 - 40 to +125
T
= - 40 to +100 - 40 to +125
H
= - 40 to +100 - 55 to +125
M
= - 55 to +100 - 65 to +125
B
Output Power
P
OUT
200W, 264W
300W, 400W
400W
300W
300W, 400W, 500W
300W, 400W
300W, 400W, 500W
300W, 400W, 500W
300W, 400W
300W, 400W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
6.5
= 6.5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
V
OUT
3.3V
5V
6.5V
8V
12V
15V
24V
28V
36V
48V
24V Maxi Family
Page 1 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
14.8
36.3
17.5
15.3
37.8
39.6
4.0
Min
18
Typ
24
Max
36
50
17.9
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Notes
These modules will operate at up to 75% of rated power down
to 16V
IN
after start up at >18V
IN
<100ms
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to -OUT, +Sense to -OUT – Absolute Maximum Ratings
3.3V
5V
6.5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 9.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.2
-0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 10.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20263)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.08
0.07
4.9
1.1
165
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
24V Maxi Family
Page 2 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
6.5
(184.3)
7.4
(209.3)
100
3000
1500
500
10
7.3
(207.5)
8.2
(232.5)
115
cURus, cTÜVus, CE
8.1
(230.7)
9.0
(255.7)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
24V Maxi Family
Page 3 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3V
OUT
, 264W (e.g. S24A3V3C264BL, V24A3V3C264BL)
Parameter
Efficiency
S24A3V3C264BL (enhanced efficiency)
V24A3V3C264BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.0
80.0
4.14
Typ
86.0
81.4
75
4.3
8
±0.02
92
92
Max
Unit
%
94
4.46
12
±0.2
80
108
108
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
3.3V
OUT
, 200W (e.g. S24A3V3C200BL, V24A3V3C200BL)
Parameter
Efficiency
S24A3V3C200BL (enhanced efficiency)
V24A3V3C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.0
73.9
4.48
Typ
86.0
79.9
43
4.65
6.2
±0.02
69.7
69.7
Max
Unit
%
54
4.82
10
±0.2
60.6
81.9
81.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.8
42.4
5V
OUT
, 400W (e.g. S24A5C400BL, V24A5C400BL)
Parameter
Efficiency
S24A5C400BL (enhanced efficiency)
V24A5C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
80.0
6.03
Typ
86.5
84.5
152
6.25
6.8
±0.02
92
92
Max
Unit
%
190
6.47
10.1
±0.25
80
104
104
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
5V
OUT
, 300W (e.g. S24A5C300BL, V24A5C300BL)
Parameter
Efficiency
S24A5C300BL (enhanced efficiency)
V24A5C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.5
82.5
6.03
Typ
84.4
84.4
120
6.25
7.2
±0.02
69
69
Max
Unit
%
150
6.47
8.8
±0.2
60
81
81
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.2
42
24V Maxi Family
Page 4 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
6.5V
OUT
, 400W (e.g. S24A6V5C400BL, V24A6V5C400BL)
Parameter
Efficiency
S24A6V5C400BL (enhanced efficiency)
V24A6V5C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85.0
85.0
7.7
Typ
86.1
86.1
220
7.98
9.2
±0.02
70.7
70.7
Max
Unit
%
275
8.26
10.5
±0.2
61.5
83.1
83.1
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
62.7
43
8V
OUT
, 300W (e.g. S24A8C300BL, V24A8C300BL)
Parameter
Efficiency
S24A8C300BL (enhanced efficiency)
V24A8C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.6
85.6
9.36
Typ
86.5
86.5
215
9.7
8.7
±0.02
43.1
43.1
Max
Unit
%
269
10.1
13.9
±0.2
37.5
50.7
50.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
38.2
26.2
12V
OUT
, 500W (e.g. S24A12C500B, V24A12C500BL)
Parameter
Efficiency
S24A12C500B (enhanced efficiency)
V24A12C500BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.7
86.0
13.8
Typ
88.2
87.5
272
14.3
10.8
±0.02
47.9
47.9
Max
Unit
%
340
14.8
12.0
±0.2
41.67
56.3
56.3
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
42.5
29.2
12V
OUT
, 400W (e.g. S24A12C400BL, V24A12C400BL)
Parameter
Efficiency
S24A12C400BL (enhanced efficiency)
V24A12C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.0
87.0
13.7
Typ
89.5
88.3
250
14.3
6.8
±0.02
38.4
38.4
Max
Unit
%
320
14.9
10.2
±0.2
33.33
43.5
43.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
[size=3]Have you ever encountered this situation, when doing circuit design, you want to look at the reference design, but the reference circuit from Baidu completely pits you. When I was in school, I...
The first step is to create a new project and add the master device, as shown in the following figureThe second step is to import the EDS file of the Inovance inverter, as shown in the following two f...
Recently, I have collected some files related to cracking AD15 and shared them with you. There are many licenses in it. Try a few of them. There is always one that works. I have cracked it successfull...
I would like to ask about the sampling effective bit problem. Why will the effective bit be lost? I am using DSP28035. Are the 12 bits mentioned above the effective bits?...
[color=blue]I have also been paying attention to small islands recently. I saw another article about small islands. Imagine if one day you suddenly have money and can buy a small island, what would yo...
My goal is to automatically generate a target .c file on the C# platform, and the compilation work needs to use gcc under linux to compile my target .c file. (Considering that the executable file comp...
1. Overview
Will passive devices
produce nonlinear intermodulation distortion? The answer is yes! Although there is no systematic theoretical analysis, it has been found in engineerin...[Details]
As a wireless broadband metropolitan area network standard, WiMAX technology has greater advantages than previous 3.5GHz MMDS products in terms of non-line-of-sight transmission and spectrum utiliz...[Details]
1 Introduction
With the acceleration of the pace of urban modernization, society has higher requirements for urban road lighting and urban lighting projects. The state has clearly required tha...[Details]
AD8205 is
a single-supply high-performance differential
amplifier
launched by
Analog
Devices of the United States
. The typical single-supply voltage is 5V, and its common-mode volta...[Details]
This week, Microsoft held its 2012 Microsoft Worldwide Partner Conference (WPC) in Toronto, Canada. At the conference, Microsoft showed its new products and services to partners around the world. A...[Details]
1. Proposal of
reconfigurable
measurement and control system
The measurement and control system generally refers to a system based on
computers
to realize data acquisition a...[Details]
A stepper motor is an electromagnetic mechanical device that converts an electrical pulse signal into an angular displacement or a linear displacement. The stability and reliability of a stepper mo...[Details]
Don’t just look at the power when choosing a power supply
We know that a power supply with a low rated power can hardly meet the power supply needs of the system, which may cause frequent free...[Details]
1. Tips for charging UPS for the first time
After purchasing a new UPS, plug the UPS into the 220V mains power grid and charge it for at least 12 hours to ensure that the battery is fully char...[Details]
Infrared remote control is widely used in home appliances, but the remote controls produced are not compatible with each other. The universal remote controls commonly seen on the market can only co...[Details]
In some motion control systems with simple control or low cost requirements, stepper motors are often used as actuators. The biggest advantage of stepper motors in such applications is that they ca...[Details]
Various electronic and electromagnetic interference inside and outside the car often puts automotive electronic equipment in dangerous working conditions, degrading the performance of electronic eq...[Details]
If users want to extend the effective use time of the battery, in addition to ensuring the quality of the charger, correct charging techniques are also essential. Here are 14 tips for charging mobile ...[Details]
According to a survey by the International Energy Agency, Asia and Australia used 1.65 trillion liters of oil for energy in 2004. The survey also showed that since 1990, the demand for oil has been...[Details]
1. Self-test of lithium battery capacity
The nominal capacity of the CECT9898 OEM mobile phone lithium battery is 3800mAh, and its battery volume is comparable to the 1500mAh battery of ot...[Details]