One of the reverse braking circuits for one-way operation
Source: InternetPublisher:消失的歌 Keywords: Braking circuit contacts BSP intermediate relay Updated: 2021/02/09
The circuit is shown in Figure 3-124. This circuit does not use intermediate relays . In the figure, Kv is the speed relay. When the motor
speed is greater than 120 r/min, the contact is closed. When the motor speed is lower than 100 r/min, the contact is open. When stopping, the contactor KMi is released
, KMz is closed, and the reverse braking is performed. When the speed is lower than 100r/min, the Kv contact is disconnected. KM2 is released and the braking process
ends (about 1 to 3 seconds). The purpose of connecting the braking resistor R is to limit the reverse braking current. R can also be connected to only two phases.
- How to choose the right level of integration to meet motor design requirements?
- How to Make a Simple Chicken Incubator
- A small improvement on the ordinary refrigerator motor starting circuit
- Working principle of ZNB-S digital display intelligent motor protector control circuit
- Motor control circuit for starting and running without phase loss
- Design and analysis of touch delay switch circuit composed of CD4011 and CD4001
- Design and analysis of voice control circuit
- Electric vehicle battery charging protection circuit
- Design and production of no-load automatic power-off device for household power supply
- Precious home appliance anti-theft alarm
- Electric massager circuit
- Egg warming circuit
- Rice mill circuit
- Straw returning to field crusher circuit
- Particle clogging alarm circuit of wheat seeder
- Electrical schematic diagram of DC voltmeter input at non-inverting terminal
- Frequency modulator composed of NE566
- Simple AGC circuit in transistor radio
- Multi-frequency resonant high-frequency power amplifier circuit for transmitter stage
- Home appliance repair signal generator circuit