EEWORLDEEWORLDEEWORLD

Part Number

Search

LGA100A-24-HSNY

Description
DC Power Cords INPUT MATING HARNESS
CategoryPower/power management    The power supply circuit   
File Size805KB,11 Pages
ManufacturerCosel
Download Datasheet Parametric View All

LGA100A-24-HSNY Online Shopping

Suppliers Part Number Price MOQ In stock  
LGA100A-24-HSNY - - View Buy Now

LGA100A-24-HSNY Overview

DC Power Cords INPUT MATING HARNESS

LGA100A-24-HSNY Parametric

Parameter NameAttribute value
MakerCosel
package instruction,
Reach Compliance Codeunknown
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
AC-DC Power Supplies Open Frame/ Enclosed Type
Ordering information
LGA50A
LG
1
2
A
3
50
4
A
5
-5
6
-O
R
Recommended EMI/EMC Filter
NAC-06-472
LGA
LGA
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
1Series
name
2Single
output
3Output
wattage
4100/120V
input
5Output
voltage
6Optional
C :with Coating
G :Low leakage current
H :with the function to be
acceptable to output
peak current (only 24V)
J1:VH(J.S.T.)connector
type
S :with Chassis
SN:with Chassis & cover
Y :with Potentiometer
This power supply is manufactured by SMD technology.The stress to P.C.B like twisting or bending causes the defect of the unit,so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LGA50A-3R3-Y LGA50A-5
33
50
3.3V 10A
5V 10A
LGA50A-12
51.6
12V 4.3A
LGA50A-15
52.5
15V 3.5A
LGA50A-24
60
24V 2.5A
LGA50A-24-H LGA50A-48
60
62.4
(Peak 3.2) A 48V 1.3A
24V 2.5
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V
INRUSH CURRENT[A] ACIN 100V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
*
3
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
*
1
*
4
RIPPLE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
*
1
*
4
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
*
4
TEMPERATURE REGULATION[mV]
-10 to +50
C
*
4
*
2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
LGA50A-3R3-Y LGA50A-5
LGA50A-12
LGA50A-24
LGA50A-24-H LGA50A-48
LGA50A-15
AC85 - 132 1
f
(Refer to Instruction Manual 1.1, and 3.2 Derating)
0.8typ (Io=100%) 1.3typ (Io=100%)
47 - 440 (Refer to Instruction Manual 1.1)
74.0typ (Io=100%) 79.0typ (Io=100%) 82.0typ (Io=100%) 83.0typ (Io=100%) 85.0typ (Io=100%) 85.0typ (Io=100%) 85.0typ (Io=100%)
30typ (Io=100%), (At cold start), (Ta= 25C)
0.5max (ACIN 100V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
12
24
24
5
15
48
(Peak 3.2) 1.3
10.0
4.3
2.5
2.5
10.0
3.5
20max
48max
96max
96max
20max
60max
192max
40max
100max
150max
150max
40max
120max
300max
80max
120max
150max
80max
120max
120max
240max
140max
160max
160max
320max
140max
160max
200max
120max
150max
150max
300max
120max
150max
350max
160max
180max
400max
160max
180max
180max
360max
50max
150max
480max
50max
120max
240max
240max
60max
150max
290max
290max
60max
180max
600max
20max
48max
96max
96max
20max
60max
192max
200max (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
Fixed ("Y"which can be adjusted the output is available as optional
t
10%)
2.85 - 3.63
4.90 - 5.30
14.40 - 15.60
46.00 - 50.00
3.30 - 3.40
11.50 - 12.50
23.00 - 25.00
23.00 - 25.00
Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically
13.80 - 16.80
17.30 - 21.00
27.60 - 35.00
27.60 - 35.00
55.20 - 67.20
5.75 - 7.00
4.00 - 5.25
Not provided
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
50
X
28.5
X
132mm [1.97
X
1.12
X
5.2 inches] (W
X
H
X
D) / 160g max (with chassis & cover : 320g max)
Convection (Refer to Instruction Manual 3.2)
*4
*
*
*
*
Only output 24V and 48V DC models are applied that the upper temperature limit is 45C.
Avoid prolonged use under over - load.
Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
A sound may occur from power supply at pulse loading.
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
This is the value that measured on measuring board with capacitor of 22mF at 150mm from
output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:
RM-103).
*2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*3
Peak loading for 10sec.And Duty 35% max.or less is acceptable if the total wattage is less
than the rated wattage (24V:60W).
Refer to instruction Manual 5. In detail.
LGA-2
Hall sensor applied to brushless motor drive control
The problems of using Hall elements in brushless motor control systems are discussed, and Hall integrated sensors are explored. Two methods of using Hall integrated sensors to form brushless motor con...
frozenviolet Sensor
What is the reason for the contacts of the contactor used for lighting distribution in the steel plant to burn?
What is the reason for the contacts of the contactor used for lighting distribution in the steel plant to burn? Our company recently adopted LC1-D245M7C AC contactor for lighting power distribution in...
eeleader-mcu Industrial Control Electronics
Please help analyze why intLock cannot lock the interrupt
One of the company's projects uses MIPS CPU and found that calling intLock() is invalid, but various interrupts are still generated. The code disassembled by IDA is as follows: .text:80050524 # ======...
wisyjt Embedded System
2014 Jiangsu Province Electronic Design Competition Topic A (TI Cup): Quadcopter Competition Works
I am a student at Nanjing Normal University Xianlin Campus, and I participated in this year's TI Cup. I prepared for this electronic design competition for a long time, but I always thought that there...
1201yuge Microcontroller MCU
Share the LED driver of DSPTMS320F28035
[list=1] [*][size=3]/************************************ [/size] [*][size=3]标题:LEDs.h [/size] [*][size=3]软件平台:DSP.com/forum.php?mod=forumdisplay&fid=58" target="_blank" class="relatedlink">CCS v5.2 [...
灞波儿奔 DSP and ARM Processors
Using Power Management
Power management allows you to reduce overall power consumption by slowing down workstation activity when the workstation is idle. For more information about power consumption, refer to the HP Worksta...
zbz0529 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2920  1195  1824  566  2428  59  25  37  12  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号