Solid State Relay
G3MB
Low cost Subminiature PCB mounting
2 amp Single in-line package (SIP) SSR
• Bottom is approximately 3 times smaller than G3M.
• Low cost “SIP” package switches up to 2A loads.
• Built in Snubber circuit and input resistor as option.
• Two footprints available for design flexibility.
• The G3MB-202PEG-4-DC20MA crosses directly to the
Motorola M0C2A-60 series power triac.
Ordering Information
To Order: Specify input voltage at end of part number. Example: G3MB-202P-DC24
Isolation
Output
terminal
pitch
7.62 mm
Zero
cross
Yes
Input
resistor
Yes
Built-in
snubber
circuit
Yes
Rated output
load
2 A at 100 to 240 VAC
Rated
input
voltage
5 VDC
12 VDC
24 VDC
No
2 A at 100 to 240 VAC
5 VDC
12 VDC
24 VDC
5.08 mm
Yes
2 A at 100 to 240 VAC
5 VDC
12 VDC
24 VDC
No
2 A at 100 to 240 VAC
5 VDC
12 VDC
24 VDC
Yes
No
No
No
2 A at 100 to 240 VAC
2 A at 100 to 240 VAC
N/A *
(See Note)
N/A *
(See Note)
G3MB-202PEG-4-DC20MA
G3MB-202PLEG-4-DC20MA
G3MB-202PL-4
G3MB-202P-4
G3MB-202PL
Model
Phototriac
G3MB-202P
Note: 1.
For versions without input voltage specified, a current limiting resistor must be placed in series with the input. See LED drive specifications
and recommendations below.
2.
TUV versions available. Contact your local Omron representative.
1
Solid State Relay
G3MB
Specifications
■
Input Rating
Models with Input Resistor
Rated voltage
5 VDC
12 VDC
24 VDC
4 to 6 VDC
9.60 to 14.40 VDC
19.20 to 28.80 VDC
Operating range
440
Ω
±20%
1k
Ω
±20%
2.20k
Ω
±20%
Input impedance
■
Output Rating
Model
G3MB-202
Rated load voltage
100 to 240 VAC
Load voltage range
75 to 264 VAC
Load current
0.10 to 2 A
Surge current
30 A (60 Hz, 1 cycle)
■
LED Drive Data
Models without Input Resistor
LED forward current
Repetitive peak LED forward current
LED reverse voltage
50 mA max.
1 A max.
5 V max.
■
Recommended LED Operating Conditions
Models without Input Resistor
Min.
LED forward current
Must drop voltage
5 mA
0
10 mA
—
Standard
20 mA
1V
Max.
■
Characteristics
Type
Operate time
Release time
Output ON voltage drop
Leakage current
Non-repetitive peak surge
Output
PIV (V
DRM
)
di/dt
dv/dt
It
Junction temperature (Tj)
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Weight
Note:
Data shown are of initial value.
Malfunction
Malfunction
Operating
Storage
Operating
2
G3MB-202P
G3MB-202PEG
1/2 of load power source
cycle + 1 ms max.
1.60 V (RMS) max.
1 mA max. at 100 VAC, 1.50 mA at 200 VAC
30 A
600 V
40 A/µs
100 V/µs
4 A
2
s
125°C (257°F) max.
1,000 MΩ min. at 500 VDC
G3MB-202PL
G3MB-202PLEG
1 ms max.
1/2 of load power source cycle + 1 ms max.
2500 VAC, 50/60 Hz for 1 minute; 3750 VAC max., 1 second
10 to 55 Hz, 0.75 mm (0.03 in) double amplitude, approx. 5 G
Approx. 100 G
-30° to 80°C (-22° to 176°F) with no icing
-30° to 100°C (-22° to 212°F) with no icing
45% to 85% RH
Approx. 5 g (0.18 oz)
Solid State Relay
G3MB
2
■
Characteristic Data
Load current vs. ambient
temperature characteristics
2.5
Inrush current resistivity
Non-repetitive (Keep the inrush current to
half the rated value if it occurs repetitively.)
40
Switching current (A)
2.0
Inrush current (A Peak)
30
1.5
20
1.0
0.5
10
0
-40
-20
0
20 25 40
60
80
100
0
10
100
30 50 100 300 500 1,000
Switching current (A)
5,000 10,000
Ambient temperature ˚C
Dimensions
Unit: mm (inch)
■
Relays
PCB Dimensions
(Bottom view)
G3MB
Four 1.0 (0.04) dia.
20.5
(0.81)
max.
2.54 (0.1)
2.54
(0.1)
3.9 (0.15)
2.54 (0.10)
24.5 (0.96)
max.
7.62
(0.30)
0.7
(0.03)
1.4 (0.06)
0.4 (0.02)
G3MB (-4)
Four 1.0 (0.04) dia.
5.5
(0.22)
max
2.54 (0.1)
2.54
(0.1)
Terminal
Arrangement/
Internal Connections
(Bottom view)
4 (-) 3 (+)
2
1
INPUT
LOAD
3
Solid State Relay
G3MB
■
Approvals
UL (File No. E64562)
SSR Type
G3MB-102P
Input voltage
5 to 24 VDC
Load type
General purpose
Tungsten
Motor
G3MB-202P
G3MB-202PL
G3MB-202PEG
G3MB-202PLEG
General purpose
Tungsten
Motor
2 A, 120 VAC
1 A, 120 VAC
1.60 FLA/9.60 LRA, 120 VAC
2 A, 240 VAC
1 A, 240 VAC
1.60 FLA/9.60 LRA, 240 VAC
Load ratings
CSA (File No. LR35535)
SSR Type
G3MB-102P
Input voltage
5 to 24 VDC
Load type
General purpose
Tungsten
Motor
G3MB-202P
G3MB-202PL
General purpose
Tungsten
Motor
2 A, 120 VAC
1 A, 120 VAC
1.60 FLA/8.60 LRA, 120 VAC
2 A, 240 VAC
1 A, 240 VAC
1.60 FLA/8.60 LRA, 240 VAC
Load ratings
Note: 1.
The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics
individually defined in this catalog.
2.
In the interest of product improvement, specifications are subject to change.
Precautions
See General Information Section near the back of this catalog for
Solid State Precautions.
Soldering must be completed within 10 seconds at 260°C or less.
Make sure that the space between the bottom of the relay and the
PCB is 0.1 mm or less. When making holes on the PCB for the
relay’s edge terminals, the hole diameters should be slightly smaller
than the actual diameters of the edge terminals. This will reduce
unnecessary space between the bottom of the relay and the PCB.
To use the SSR output for phase control, select a model that does
not incorporate a zero-cross function.
The SSR case serves to dissipate heat. When mounting more than
three SSRs as a group, pay attention to the ambient temperature rise
and install the Relays so that they are adequately ventilated. If poor
ventilation is unavoidable, reduce the load current by half.
Protective Component
The input circuitry does not incorporate a circuit protecting the SSR
from being damaged due to a reversed connection. Make sure that
the polarity is correct when connecting the input lines.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4
Solid State Relay
G3MB
4
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4
OMRON ELECTRONICS LLC
One Commerce Drive
Schaumburg, IL 60173
OMRON CANADA, INC.
885 Milner Avenue
Toronto, Ontario M1B 5V8
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.ca
847-882-2288
416-286-6465
Cat. No. GC RLY8
5/03
Specifications subject to change without notice
Printed in USA
5
Solid State Relay
G3MB