EEWORLDEEWORLDEEWORLD

Part Number

Search

890-005-9GST-2C2-12TJ

Description
Interconnection Device
CategoryThe connector   
File Size195KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

890-005-9GST-2C2-12TJ Overview

Interconnection Device

890-005-9GST-2C2-12TJ Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
Series 89 Nanominiature Connectors
Single Row Back-To-Back Cables
890-005
Glenair’s Back-To-Back Nano Connectors
feature gold
alloy NanoPin contacts. Contacts are precision-crimped
to insulated, stranded wire. These nanomimiature
connectors offer premium preformance and reliability
for demanding applications. Contact spacing is .025
inches. 1 amp current rating, DWV rating 300 volts AC.
Wire gages #30 and #32 AWG.
NanoPin Contact System
assures premium performance in
demanding environments. The gold/platinum alloy contacts
will stand up to years of exposure without corrosion.
Typical Applications
include UAV's, satellites, missile
systems and geophysical instruments.
HOW TO ORDER SINGLE ROW BACK-TO-BACK JUMPERS
Number
of
Connector Shell Material
Contacts
Type
and Finish
9
15
21
25
31
37
51
GP
A1
Wire
Gage
0
#30
AWG
Series
890-005
Back-To-
Back Cables,
Single Row,
Nanominiature
Wire Type
A
Ultralightweight XLETFE
Insulation, Silver-Coated
Ultrahigh-Strength Copper
(Not available for #32 gage)
Wire
Color
Code
1
White
2
Yellow
7
Ten
Color
Repeat
Length
Inches
Overall
Length
In Inches
Hardware
JJ
= Jackscrews on
both ends (GP, GS, CS)
Plug (Pin)
Aluminum Shell,
Connector on Cadmium Plating
Both Ends
JT
= Jackscrews on
A2
GS
Receptacle
(Socket)
Connector on
Both Ends
Aluminum Shell,
Electroless
Nickel Plating
2
#32
AWG
Including
plug, threaded holes on
Connectors
receptacle (CS)
Example:
“12”
specifies
12 inches
OAL
B
Extruded PTFE Insulation,
NEMA HP3-ETX
(MIL-W-16878/6)
JP
= Jackscrews on
plug, threaded holes on
plug (GP)
TJ
= Jackscrews on
receptacle, threaded
holes on plug (CS)
T
CS
Plug (Pin)
On One End,
Receptacle On
The Other End
Titanium Shell,
Unplated
C
Cross-Linked Modified
ETFE Insulation,
MIL-W-22759/33
(Not available for #32 AWG)
S
Stainless Steel
Shell, Passivated
JR
= Jackscrews on
receptacle, threaded
holes on receptacle
(GS)
TT
= Threaded holes
both ends (GP, GS, CS)
Sample Part Number
890-005
– 9
GP
A1
– 0
A
1
– 12
JP
PLUG (PIN) CONNECTOR
RECEPTACLE (SOCKET) CONNECTOR
“J” Jackscrew Option
“T” Threaded Insert Option
“T” Threaded Insert Option
“J” Jackscrew Option
© 2006 Glenair, Inc.
CAGE Code 06324/0CA77
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
P-10
E-Mail: sales@glenair.com
[Learn device indicators together] Do you dare to say a resistance indicator that everyone doesn’t know?
Resistors are used in almost all electronic designs. Let me ask you a question. What parameters and indicators of resistors do you know?Do you dare to mention an indicator that no one knows?This is us...
wstt Microcontroller MCU
I just got a call from Altium.
Yesterday I downloaded and installed Altium Designer. I had to register when downloading. After registering, I downloaded and installed it online. Doesn’t that require a license? Of course, I used it ...
wangfuchong Talking
Introduction to three interrupt debugging methods of ARM
[size=4]1 Embedded Software Development Process [/size] [size=4] [/size] [size=4] Refer to the embedded software development process. Step 1: Project establishment and configuration. Step 2: Edit sour...
Aguilera Microcontroller MCU
Ask a superconductivity question
Suppose a superconducting ring is made magnetic by an alternating magnetic field, which is theoretically caused by the circulation of electric current. If the temperature suddenly rises, will the curr...
bigbat Power technology
How to Regulate Low Voltage Isolated Power Supplies
[p=16, null, left][color=rgb(51, 51, 51)][size=12px][color=#cd171f][url=http://www.ti.com/hval-sll-lin-powerlab-pwrhouse-20140116-tl431-pf-en]TL431[/url][/color] Shunt regulators are perhaps the most ...
wstt Power technology
A newbie asking for help.... About the usage of m2716...
I have never come across this type of chip before. Now I need to use it, but I don't know how to use it. Can anyone tell me how to load data into M2716 in Proteus, and what to use to burn data into it...
guoyaru123 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 199  2249  974  918  495  5  46  20  19  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号