EEWORLDEEWORLDEEWORLD

Part Number

Search

DGM310-313

Description
Industrial Pressure Sensors FEMA
CategoryThe sensor   
File Size449KB,22 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

DGM310-313 Online Shopping

Suppliers Part Number Price MOQ In stock  
DGM310-313 - - View Buy Now

DGM310-313 Overview

Industrial Pressure Sensors FEMA

DGM310-313 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerHoneywell
Product CategoryIndustrial Pressure Sensors
ProductPressure Switches
Pressure TypeDifferential
Accuracy< 1 %
Port SizeG 1/2, G 1/4
Operating Supply Voltage250 VAC
PackagingBulk
Pressure PortPort
Mounting StylePanel
Maximum Operating Temperature+ 60 C
Minimum Operating Temperature- 25 C
Operating Supply Current8 A
Factory Pack Quantity1
58
Mechanical pressure switches
Tested to PE Directive 97/23/EC
DGM
Pressure monitors for fuel gases
DVGW tested to DIN EN1854
Gas pressure monitors are suitable
for all gases in accordance with DVGW
Worksheet G260 and for air.
SIL 2 according IEC 61508-2
DGM310A
Technical data
Pressure connection
External thread G 1/2 to DIN 16 288 and
internal thread G 1/4 to ISO 228 Part 1
(permissible up to 4 bar).
Switching device
Seawater-resistant diecast aluminium
GD AI Si 12.
Protection class
IP 54 for vertical installation position.
Pressure sensor materials
See Product Summary
Ambient temperature
–25 to +60°C.
At ambient temperatures below 0°C, ensure
that condensation cannot occur in the sensor
or in the switching device.
Maximum working pressure
See Product Summary
Mounting
Either directly on the pipe or with
two 4 mm ø screws on the wall surface.
Mounting position
Vertically upright and horizontal.
Setting
Continuously adjustable via the setting spindle
with a screwdriver. The set switching pressure
is visible in the scale window.
Sealing P2
On request (can be fitted later).
Switching differentials
Largely independent of the set switching
pressure. Not adjustable. For values see
Product Summary.
Switching
capacity
Normal
250 VAC 250 VDC 24 VDC
(ohm) (ind) (ohm) (ohm)
8A 5A
0.3 A
8A
Component tested for
Testing basis
Function
Fuel gases according to DVGW Worksheet G 260
DIN EN1854
Pressure monitor
Direction of action
For maximum and minimum
pressure monitoring
Product Summary
Type
Setting range
Switching
Max.
differential
working
(mean values) pressure
Materials
Dimen-
in contact
sioned
with medium drawing
p. 25 + 26
DGM306A
DGM310A
DGM325A
DGM06A
DGM1A
DGM506
DGM516
DGM525
15…60
20…100
40…250
100…600
0.2…1.6
15…60
40…160
100…250
mbar
mbar
mbar
mbar
bar
mbar
mbar
mbar
6
7
10
25
40
8
12
20
mbar
mbar
mbar
mbar
mbar
mbar
mbar
mbar
0.8
0.8
0.8
2
3
5
5
5
bar
bar
bar
bar
bar
bar
bar
bar
CU + Ms
CU + Ms
CU + Ms
CU + Ms
CU + Ms
1.4104
1.4104
1.4104
1 + 13
1 + 14
1 +12
Calibration
The
DGM
series is calibrated for rising pressure. This means that the adjustable switching pressure on
the scale corresponds to the switching point at rising pressure. The reset point is lower by the amount of
the switching differential. (See also page 27, 2. Calibration at upper switching point).
For other pressure ranges see type series DWR, page 59.
Ex-i version (intrinsically safe)
As above, but with additional function ZF513 (Ex-i).
Example for ordering:
DGM516-513
Pressure measuring connection
Care must be taken to ensure that a pressure
measuring connection is available in a suitable
place on the gas appliance.
-DGM see page 70
s
DVGW
TÜV
Protection Class:
IP 54
Interested in FPGA, how to get started?
Interested in FPGA, how to get started?...
niqingliang2003 FPGA/CPLD
IAR FOR MSP430G2553 supports Printf function
Some time ago, when I was using Keil, I used the Printf function and it worked very well. These two days, when I was adjusting the serial port of MSP430, I suddenly thought of this, searched a lot on ...
cat3902982 Microcontroller MCU
Help! CC2530 serial port problem
I am using a module bought from tb, KLZB214A from Kelan. I can only use the serial port to burn the program. The serial port of the module suddenly cannot be used. Both rx and tx are high. This has ha...
ScottH RF/Wirelessly
TI's protel 99se package library
TI's protel 99se package library...
songbo DSP and ARM Processors
Dual machine communication method?
I saw an industrial product. The mainboard used was 430F5438, and the display board used was 430F149. The communication pins of the two microcontrollers were connected as follows: 430F5438 430F149 1. ...
sanlin1997 Microcontroller MCU
A friend said yesterday: From today on, be prepared for the lottery at any time!
Today, I would like to share with you the headlines of Beijing Entertainment News:In the future, you will need to draw lots to get a license plate when buying a car Each driver is limited to one Indiv...
soso Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2524  1079  599  1407  2785  51  22  13  29  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号