EEWORLDEEWORLDEEWORLD

Part Number

Search

AT-6020

Description
Environmental Test Equipment ADV WIRE TRACER
CategoryTopical application    Test and measurement   
File Size931KB,3 Pages
ManufacturerFluke
Websitehttps://www.fluke.com
Environmental Compliance
Download Datasheet Parametric Compare View All

AT-6020 Online Shopping

Suppliers Part Number Price MOQ In stock  
AT-6020 - - View Buy Now

AT-6020 Overview

Environmental Test Equipment ADV WIRE TRACER

AT-6020 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerFluke
Product CategoryEnvironmental Test Equipment
RoHSDetails
amprobe.com
AT-6000
Advanced Wire Tracer Series
identify breakers
Locate and trace Energized and De-energized wires, automatically
The AT-6000 Series,
available in two different kits, combines
a receiver and powerful transmitter to locate Energized and
De-energized wires, breakers, fuses and easily find breaks and
shorts. Whether you’re a novice or an expert, Amprobe advanced
wire tracers will help you get the job done fast.
The AT-6000-R Receiver
detects the signal in wires and cables
using two methods: active tracing method (with the Transmitter)
and passive tracing method (without the Transmitter). In hard-to-
reach areas, the Receiver’s Tip Sensor can be used to trace wires in
corners, tight spaces and junction boxes.
The AT-6000-T Transmitter
works on Energized and De-energized
circuits up to 600 V AC/DC in Category I through Category III
electrical environments and features high signal, low signal,
and loop modes. The Breaker Identification feature eliminates
confusion of multiple false positives, common with older
technology tracing tools, by identifiying the one correct breaker
or fuse with the highest recorded signal.
The CT-400 Signal Clamp
(optional for AT-6020, included with
AT-6030) is used for applications where is no access to the bare
conductors by enabling the AT-6000-T Transmitter to induce a
signal into a wire through the insulation.
Tip Sensor
Trace wires in
tight spaces
Full Color
TFT-LCD display
Green arrow indicates
the correct breaker is
identified
Volume
Adjustment
Shows whether
transmitter is in
high, low or loop
mode
Transmission
Mode Indicator
Four Tracing Modes
Quick Scan Wire Tracing
allows for quick wire
detection at a longer
distance
Precision Wire Tracing
precisely pinpoints wires
or faults located behind
walls, floors, or ceilings
Breaker Identification
is an automatic sensitivity
feature that allows for
quick and easy breaker
locating without the
guesswork
Non-Contact Voltage
Detection
utilizes passive
tracing without the
transmitter to verify if
a wire is Energized
Loop Mode
Indicator
Sensitivity
adjustment
High Signal Mode
Loop Mode
Low
(Precision)
Mode
Receiver
AT-6000-R
AT-6000-T
Transmitter
Safety Certification
All Amprobe tools, including the Amprobe AT-6000 Series, are rigorously tested for safety, accuracy,
reliability, and ruggedness in our state-of-the-art test lab.
In addition, Amprobe products that measure
electricity are listed by a 3rd party safety lab, either UL or CSA. This system assures that Amprobe products meet or
exceed safety regulations and will perform in a tough, professional environment for many years to come.
Amprobe
®
| info@amprobe.com | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623)
©2018 Amprobe
®
For detailed specifications and ordering go to amprobe.com 6009730 A

AT-6020 Related Products

AT-6020 AT-6030
Description Environmental Test Equipment ADV WIRE TRACER Environmental Test Equipment ADV WIRE TRACER
Product Attribute Attribute Value Attribute Value
Manufacturer Fluke Fluke
Product Category Environmental Test Equipment Environmental Test Equipment
RoHS Details Details
Is there any need for this serial port conversion module?
There are still six or seven pieces for connecting the wireless scanner base. Contact QQ244683183...
wrtrry Buy&Sell
Has anyone used irf7832?
Has anyone used irf7832? How is the driving capability of this MOS tube?...
qixiangyujj Analog electronics
Thermistor detection method
1. Detection of positive temperature coefficient thermistor (PTC): When testing, use the multimeter R×1 block, which can be divided into two steps: 1. Normal temperature test (room temperature close t...
Aguilera Analogue and Mixed Signal
How to configure GPIO interrupt for TIC6000?
1) Enable the general purpose input and output port peripheral (GPIO). 2) Configure the corresponding GPIO port as a normal input and output port (select the multiplexing function in I/O multiplexing)...
Aguilera DSP and ARM Processors
Sharing practical experience of "ESD protection circuit design" for PCB boards!!!
[p=null, 2, center][color=rgb(51, 51, 51)]Static electricity from the human body, the environment, and even inside electronic devices can cause various damages to precision semiconductor chips, such a...
ohahaha PCB Design

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 196  271  1950  1004  2150  4  6  40  21  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号