Description
CAP PUSHBUTTON RECTANGULAR GRAY
Categoryaccessories   
File Size1020KB,9 Pages
ManufacturerC&K
Environmental Compliance
Download Datasheet Parametric View All

F1204 Online Shopping

Suppliers Part Number Price MOQ In stock  
F1204 - - View Buy Now

F1204 Overview

CAP PUSHBUTTON RECTANGULAR GRAY

F1204 Parametric

Parameter NameAttribute value
Switch typebutton
shaperectangle
colorgrey
illuminationNot glowing
Supporting products/related productsF series
Installation typesnap-in
size9.78mm length x 5.51mm width x 11.18mm height
characteristic-
F Series
Pushbutton Switches
Features/Benefits
Up to 10 poles per module
Various contact terminals
Various mounting & switch
ganging configurations
Typical Applications
Audio selection
Digital equipment interface
Medical equipment interface
A
Pushbutton
Mechanical indicator buttons
RoHS compliant
Specifications
SWITCHING POWER: F module max. AC/DC: Silver: 50 VA/15W,
Gold: 1 VA/300 mW.
SWITCHING VOLTAGE: F module max. AC/DC: Silver: 125/30V,
Gold: 50/30 V.
TYPICAL F OPERATING FORCE: 2U: 6.5N (650 grams); 4U: 6.5N
(650 grams); 6U: 7.5N (750 grams); 8U: 9.0N (900 grams); 10U:
9.0N (900 grams).
EUROPEAN TYPICAL SF OPERATING FORCE:
2U: 3.5N±0.5N (350 grams±100 grams); 4U: 5N±1N (500
grams±100 grams); 6U: 6.5N±1N (650 grams±100 grams); 8U:
9.0N±1N (900 grams±100 grams).
CARRYING CURRENT: Max at d87u = 20C: Silver: < 2A, Gold: <0.5A.
OPERATING TEMPERATURE RANGE: -40˚C to 70˚C.
DIELECTRIC STRENGTH (50 Hz, 1 min.): Chassis/contact: ^1500V
SWITCHING CURRENT: F module max. AC/DC: Silver: 0.5A/0.5A,
Gold: 0.04A/0.01A.
Between contacts: ^1500V.
OPERATING LIFE “OA/EE” (24V/200mA): >105 operations
“GR”: >3.5 x 104 operations.
CONTACT RESISTANCE: Initial: Typical %10 mΩ, max. 20 mΩ
After operating life: %100 mΩ
INSULATION RESISTANCE: ^109 Ω between open contacts,
^109 Ω between chassis and contacts.
CAPACITANCE (at f = 10 kHz): %0.7 pF between 2 contacts.
TOTAL TRAVEL/LATCHING TRAVEL: 4.7mm/3.3mm (.185 inch/
.130 inch).
All models and options are RoHS compliant and compatible.
NOTE:
All models and options are RoHS compliant and compatible.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service Center.
Materials
HOUSING: Polycarbonate UL 94V-0 or polyester UL 94V-0.
ACTUATOR: Polyester UL 94V-0.
MOVABLE CONTACTS: Bimetal brass, silver plated, gold plate
over nickel.
STATIONARY CONTACTS & TERMINALS: Brass, silver plated,
gold plated.
TERMINAL BOARD: Polyester UL 94V-0.
RETURN SPRING: Music wire.
TERMINAL SEAL: RTV adhesive sealant.
CHASSIS: Steel.
LOCKOUT PIN: Steel.
BLOCKERS: Steel.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown
and described on pages A-88 thru A-95. For additional options not shown in catalog, consult Customer Service Center.
If requesting only a switch, select either a North American or European switch as noted below. Chassis and buttons are sold
separately. If multiple stations are selected, we will assume all switches are the same unless noted otherwise.
North American Order Code - Switch Only
Designation
F
F Series
FLT
Light touch F series
ZF
Central mounted F series
Contact Arrangement
2U
2PDT
Mechanical Function
4U
4PDT
OA
Momentary
6U
6PDT
EE
Alternate (push-push)
8U
8PDT
GR
Interlock
10U
1OPDT
AOR
Central release
OASP
Momentary with lockout
GRSP
Interlock with lockout
Terminal Sealing
(NONE)
None
TB
Top/bottom
Terminal Style
(NONE)
Solder lugs & PC pins
01A
Cut solder lugs
01B
Cut PC pins, for other configurations,
consult factory
Electrical Function
(NONE)
BBM Break-Before-Make
M
MBB (special) Make-Before-Break
Contact Material
(NONE)
Silver, AG
AU
Gold
Dress nut*
*Central mounted F series only
(NONE)
No dress nut
B
Black
C
Chrome
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A-87
www.ckswitches.com
How to debug mmu mapping, what method do you use?
What methods do everyone use? I feel like I have taken a lot of detours. Are there any good methods you can share with everyone?...
xxc5552004 Embedded System
I would like to ask how to control the buzzer under vxworks?
As the title says, I want to control the buzzer under vxworks. I wonder if you can give me some advice. Thanks....
yanghui_45 Real-time operating system RTOS
What is the difference between TIM1 of stm32f407 and other standard timers?
[i=s] This post was last edited by helenhll on 2014-11-12 16:36 [/i] I use the timer to do input capture. The same program works for TIM3 but not for TIM1. The PB0 pin used is chanel 3 of TIM3 and cha...
helenhll stm32/stm8
About stm32f4xx_fsmc.c compilation error
[i=s]This post was last edited by Jingshizhiyong on 2013-12-24 14:25[/i] I referred to several methods of creating new projects and combined them to create a new project template. As shown in the figu...
经世致用 stm32/stm8
What technology is more popular now?
Are 8-bit microcontrollers going to be eliminated soon? The cost of 32-bit microcontrollers has also dropped a lot. Will 32-bit microcontrollers dominate the market in the future, just like 8-bit micr...
风清扬1689 MCU
Loudspeaker circuit design and implementation of automatic volume adjustment of loudspeakers
Loudspeaker circuit design and implementation of automatic volume adjustment of loudspeakers...
spbsbb Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 350  782  731  534  2578  8  16  15  11  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号