EEWORLDEEWORLDEEWORLD

Part Number

Search

RSF100JB-100K

Description
Fixed Resistor, Metal Oxide Film, 1W, 100000ohm, 350V, 5% +/-Tol
CategoryPassive components    The resistor   
File Size184KB,2 Pages
ManufacturerYAGEO
Websitehttp://www.yageo.com/
Environmental Compliance
Download Datasheet Parametric View All

RSF100JB-100K Overview

Fixed Resistor, Metal Oxide Film, 1W, 100000ohm, 350V, 5% +/-Tol

RSF100JB-100K Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerYAGEO
package instructionAxial,
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
structureFlameproof
JESD-609 codee3
Lead diameter0.8 mm
Lead length35 mm
Manufacturer's serial numberRSF100/2WS
Number of terminals2
Maximum operating temperature155 °C
Minimum operating temperature-55 °C
Package diameter4.5 mm
Package length11.5 mm
Package formAxial
method of packingBulk
Rated power dissipation(P)1 W
resistance100000 Ω
Resistor typeFIXED RESISTOR
seriesRSF100/2WS
technologyMETAL OXIDE FILM
Terminal surfaceMatte Tin (Sn)
Tolerance5%
Operating Voltage350 V
Base Number Matches1
leaded resIsTOrs
Metal Oxide Film Resistors
Flame-Proof Type
Normal & Miniature Style [ RSF Series ]
FeaTUres
Power Rating
Resistance Tolerance
T.C.R.
Flameproof Multi-layer Coating Meets
Flameproof Feature Meets Overload Test
1/4W, 1/2W, 1W, 2W, 3W, 5W
±2%, ±5%
±300ppm/ºC
UL-94V-0
UL-1412
INTrOdUCTION
The RSF Series Metal Oxide Film Flame Proof
Resistors offer excellent performance in applica-
tions where stability and uniformity of characteristics
are desired. They provide lower cost alternatives
to Carbon Composition Resistors and General
Purpose Metal Films. Metal Oxides also can replace
many low power General Purpose wirewound ap-
plications, saving both money and time, with shorter
delivery cycles. The normal style & the miniature
style of RSF series are coated with layers of gray and
pink colors flame proof lacquer respectively.
deraTING CUrVe
For resistors operated in ambient temperatures above 70ºC, power rating must be derated in
accordance with the curve below.
Rated Load (%)
100
80
60
40
20
0
100
10
200
20
70ºC
Ambient Temperature (°C)
dIMeNsIONs
sTYle
Normal
RSF-25
RSF-50
ød
H
L
øD
RSF100
RSF200
RSF3WM
RSF300
RSF500
Miniature
RSF50S
RSF1WS
RSF2WS
RSF3WS
RSF5SS
RSF5WS
-
dIMeNsION
l
6.3±0.5
9.0±0.5
11.5±1.0
15.5±1.0
17.5±1.0
24.5±1.0
24.5±1.0
ød
2.4±0.2
3.3±0.3
4.5±0.5
5.0±0.5
6.5±1.0
8.5±1.0
8.5±1.0
H
28±2.0
26±2.0
35±2.0
33±2.0
32±2.0
38±2.0
38±2.0
ød
Unit : mm
0.55±0.05
0.55±0.05
0.8±0.05
0.8±0.05
0.8±0.05
0.8±0.05
0.8±0.05
* RSFIWS (for MB Type) ød=0.8±0.05mm
How to prevent high voltage leakage protection of equipment
In my design, the whole device is divided into control part and operation part. The control part is centered on the MCU device and is powered by 12V and 3.3V. The voltage of the operation device is 38...
bigbat Analog electronics
What is the purpose of dpCurSettings in many drivers?
如题,比如 DBGPARAM dpCurSettings = {TEXT("HH"), {TEXT("Ioctl"), TEXT("ATR"), TEXT("Protocol"), TEXT("Driver"),TEXT("Trace"),TEXT("Error"), TEXT("break"),TEXT("all"),TEXT(" unused"),TEXT("unused"),TEXT("un...
406791698 Embedded System
Please help me with some ideas about the innovation of the microcontroller project.
I want to participate in the school's scientific and technological innovation activities, and I want to use the single-chip microcomputer to make something practical. I have been thinking hard about w...
chen502 Microcontroller MCU
How can I tell whether 2440 is working properly?
I have just made a 2440 board and there is no program on it. How can I tell if the 2440 is working properly after powering on? Is there a frequency output pin that I can measure?...
lifuguo Embedded System
Problems in using voltage followers and analog switches together
I encountered a problem in the process of designing a signal processing circuit. I need help from the experts on the forum! The input signal is a 200kHz, ±20mV pulse train. The general structure of th...
hippozhu Analog electronics
Engineers have low emotional intelligence? Do you still think so after reading this? (Appreciation of some works of Keysight Technology Impression Test 1)
Who says engineers are dull, silly, and have low emotional intelligence? After watching the short video collected for the impression test, I don't believe it. If you are still like this, then you shou...
nmg Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1725  1081  64  2682  1292  35  22  2  54  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号