Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
83269 Coax - RG-188A/U Type
For more Information
please call
1-800-Belden1
General Description:
RG-188A/U type, 26 AWG stranded (7x34) .0205" silver-plated copper-covered steel conductor, TFE
Teflon® insulation, SPC braid shield (95% coverage), TFE tape jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material
1
26
7x34
Dia. (mm)
SPCCS - Silver Plated Copper Covered Steel 0.5207
1
Total Number of Conductors:
Insulation
Insulation Material:
Insulation Trade Name Insulation Material
Teflon®
Dia. (mm)
TFE - Tetrafluoroethylene 1.4732
Outer Shield
Outer Shield Material:
Type Outer Shield Material
Coverage (%)
Braid SPC - Silver Plated Copper 95.000
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material
Teflon®
TFE - Tetrafluoroethylene
Overall Cable
Overall Nominal Diameter:
2.489 mm
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-70°C To +200°C
200°C
16.370 Kg/Km
93.412 N
25.400 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
EU Directive 2011/65/EU (ROHS II):
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Military Specification:
RG Type:
Yes
No
Yes
Yes
04/01/2005
Yes
Yes
Yes
Yes
MIL-C-17D
188A/U
Plenum/Non-Plenum
Plenum (Y/N):
No
Page 1 of 2
04-07-2016
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
83269 Coax - RG-188A/U Type
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
50
Nom. Inductance:
Inductance (µH/m)
0.219827
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
95.149
Nominal Velocity of Propagation:
VP (%)
69.5
Nominal Delay:
Delay (ns/m)
4.82307
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
299.227
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
27.8885
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
1
10
50
100
200
400
700
900
1000
3.9372
8.8587
18.3736
27.2323
39.372
57.4175
77.7597
89.5713
95.149
Max. Operating Voltage - Non-UL:
Voltage
900 V RMS
Notes (Overall)
Notes:
Teflon® is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc.
Put Ups and Colors:
Item #
83269 009100
83269 0091000
83269 009500
Putup
100 FT
1,000 FT
500 FT
Ship Weight
1.400 LB
11.000 LB
5.500 LB
Color
WHITE
WHITE
WHITE
Notes
E
E
E
Item Desc
#26 COAX RG-188A/U
#26 COAX RG-188A/U
#26 COAX RG-188A/U
Notes:
E = MAY CONTAIN MORE THAN 1 PIECE. MINIMUM LENGTH OF ANY ONE PIECE IS 25'
Revision Number: 2
© 2016 Belden, Inc
All Rights Reserved.
Revision Date: 04-25-2014
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Page 2 of 2
04-07-2016