EEWORLDEEWORLDEEWORLD

Part Number

Search

800S-N012

Description
800W Single Output With Parallel Function
File Size312KB,3 Pages
ManufacturerMEAN WELL
Websitehttp://www.meanwell.com
Download Datasheet Compare View All

800S-N012 Overview

800W Single Output With Parallel Function

800W Single Output With Parallel Function
Features :
SCN-800
series
AC input range selected by switch
Protections: Short circuit / Overload / Over voltage / Over temp.
High reliability/ Low ripple noise
Built-in remote sense function
Built-in remote ON-OFF control
Built-in parallel operation function
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
Case coating with paint
2 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SCN-800-12
800S-N012
12V
66A
0 ~ 66A
792W
SCN-800-15
800S-N015
15V
54A
0 ~ 54A
810W
150mVp-p
SCN-800-24
800S-N024
24V
33A
0 ~ 33A
792W
240mVp-p
20~100% adjustment by 1~5VDC external control
1.0%
0.5%
0.5%
SCN-800-48
800S-N048
48V
16.6A
0 ~ 16.6A
796W
480mVp-p
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.)
Note.2
150mVp-p
5.0% typical adjustment by potentiometer
1.0%
VOLTAGE TOLERANCE
Note.3
1.0%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE, HOLD UP TIME
800ms, 50ms, 16ms at full load
90 ~ 130VAC / 180 ~ 260VAC selected by switch, 260 ~ 370VDC
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING TEMP., HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
47 ~ 63Hz
80%
17A / 115VAC 9A / 230VAC
60A / 230VAC
3.5mA / 240VAC
110 ~ 135% rated output power
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
110 ~ 135% follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
>100
/ measure by heat sink, near transformer
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +65 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.04% / (0 ~ 50 )
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Design refer to UL1950, CSA22.2, IEC60950
I/P-O/P, I/P-FG:1500VAC
I/P-O/P, I/P-FG, >100M Ohms / 500VDC / 25
81%
85%
87%
SAFETY &
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
Design refer to FCC part 15 class A
(Note. 4)
HARMONIC CURRENT
----
EMS IMMUNITY
----
MTBF
OTHERS
DIMENSION
PACKING
SPECIAL FUNCTION
120khrs min. MIL-HDBK-217F (25
/ 70% RH
)
291*132*68mm (L*W*H)
2.3kg; 8pcs/ 24kg /CARTON
DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Tolerence: includes set up tolerance, line regulation, load regulation.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SCN-800-SPEC 2007-11-01

800S-N012 Related Products

800S-N012 SCN-800 SCN-800-15 SCN-800-12 SCN-800-24 800S-N048 800S-N015 800S-N024 SCN-800-48
Description 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function
SD card reading and writing problems
When using a 51 single-chip microcomputer to repeatedly write data to an SD card, the card may become stuck. After the data is written, the SD card remains in a busy state....
好小子 51mcu
Recommend you a good communication website!
I have been downloading chip information from eeworld before, but I have never found such a forum. I just found it yesterday. Haha, I will come here often to communicate with you all in the future. At...
phoenzo RF/Wirelessly
EEWORLD University ---- CES 2015: Using Ethernet-AVB to stream audio files
CES 2015: Streaming Audio Files over Ethernet-AVB : https://training.eeworld.com.cn/course/417Atmel 's Senior Vice President Rob Valiton introduced our latest connected car solution at CES 2015 - usin...
dongcuipin Automotive Electronics
Qorvo Launches High-Performance BAW Filters to Support Band 41 5G Base Station Deployment
Qorvo, Inc. (NASDAQ: QRVO) today announced the QPQ1298, a high-performance n41 sub-band 5G bulk acoustic wave (BAW) filter for base station infrastructure, small cells and repeaters. Qorvo’s latest BA...
alan000345 RF/Wirelessly
Coordinator intercepts data
Now there is an endpoint device that will actively report information. How can I intercept this data in the coordinator?...
errorhello RF/Wirelessly
Google slammed by Wall Street Journal as a cyber parasite
[b]Tencent Technology News[/b] According to foreign media reports, on April 7, Beijing time, the Wall Street Journal and other traditional media such as the Associated Press once again attacked Google...
soso RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2067  680  1731  1394  2855  42  14  35  29  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号