EEWORLDEEWORLDEEWORLD

Part Number

Search

800S-N024

Description
800W Single Output With Parallel Function
File Size312KB,3 Pages
ManufacturerMEAN WELL
Websitehttp://www.meanwell.com
Download Datasheet Compare View All

800S-N024 Overview

800W Single Output With Parallel Function

800W Single Output With Parallel Function
Features :
SCN-800
series
AC input range selected by switch
Protections: Short circuit / Overload / Over voltage / Over temp.
High reliability/ Low ripple noise
Built-in remote sense function
Built-in remote ON-OFF control
Built-in parallel operation function
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
Case coating with paint
2 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SCN-800-12
800S-N012
12V
66A
0 ~ 66A
792W
SCN-800-15
800S-N015
15V
54A
0 ~ 54A
810W
150mVp-p
SCN-800-24
800S-N024
24V
33A
0 ~ 33A
792W
240mVp-p
20~100% adjustment by 1~5VDC external control
1.0%
0.5%
0.5%
SCN-800-48
800S-N048
48V
16.6A
0 ~ 16.6A
796W
480mVp-p
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.)
Note.2
150mVp-p
5.0% typical adjustment by potentiometer
1.0%
VOLTAGE TOLERANCE
Note.3
1.0%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE, HOLD UP TIME
800ms, 50ms, 16ms at full load
90 ~ 130VAC / 180 ~ 260VAC selected by switch, 260 ~ 370VDC
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING TEMP., HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
47 ~ 63Hz
80%
17A / 115VAC 9A / 230VAC
60A / 230VAC
3.5mA / 240VAC
110 ~ 135% rated output power
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
110 ~ 135% follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
>100
/ measure by heat sink, near transformer
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +65 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.04% / (0 ~ 50 )
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Design refer to UL1950, CSA22.2, IEC60950
I/P-O/P, I/P-FG:1500VAC
I/P-O/P, I/P-FG, >100M Ohms / 500VDC / 25
81%
85%
87%
SAFETY &
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
Design refer to FCC part 15 class A
(Note. 4)
HARMONIC CURRENT
----
EMS IMMUNITY
----
MTBF
OTHERS
DIMENSION
PACKING
SPECIAL FUNCTION
120khrs min. MIL-HDBK-217F (25
/ 70% RH
)
291*132*68mm (L*W*H)
2.3kg; 8pcs/ 24kg /CARTON
DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Tolerence: includes set up tolerance, line regulation, load regulation.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SCN-800-SPEC 2007-11-01

800S-N024 Related Products

800S-N024 SCN-800 SCN-800-15 SCN-800-12 SCN-800-24 800S-N048 800S-N015 800S-N012 SCN-800-48
Description 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function 800W Single Output With Parallel Function
Embedded linux - Jffs2 root file system jffs2_scan_eraseblock() error
The development board is made by myself, and there is no problem with the operation of flash when u-boot is started; if the kernel is started with ramdisk and the jffs2 file system is mounted, the ope...
冬冬瓜 Linux and Android
Brew platform, how to save power as much as possible in software development without changing the hardware. Please give me some advice
1. Power saving during use. 2. Power saving during standby mode. 3. How to save power during network synchronization. 4. How to enter deep sleep. 5. Other aspects....
snowie Embedded System
The competition is about to start, download your thoughts and make your own wishes for the competition!
[i=s]This post was last edited by paulhyde on 2014-9-15 09:00[/i] I hope our group and the groups we compete with can achieve ideal results! I am very nervous, but looking forward to it!...
ruisiwu Electronics Design Contest
"Standard Tutorial for Embedded Linux Application Development" (2nd Edition) Chapters 7-12 [E-book]
Following the previous post, everyone reported that there were only the first 6 chapters, so I have made up for them all this time and continued the last 6 chapters. Thank you for your support. {:1_13...
farsight2009 Linux and Android
What is a good way to measure distance?
I would like to ask you, what method should be used to measure the distance?...
dadu Test/Measurement
Question + Analog to digital segmentation problem
[i=s]This post was last edited by dontium on 2015-1-23 11:38[/i] This issue has actually been discussed many times, but at that time it was only for the design of dual power supplies, and the digital ...
jishuaihu Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2811  2519  648  943  15  57  51  14  19  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号