EEWORLDEEWORLDEEWORLD

Part Number

Search

231-632/017-000

Description
Strip Terminal Block, 15A, 2.5mm2, 1 Row(s), 1 Deck(s),
CategoryThe connector    terminals   
File Size3MB,2 Pages
ManufacturerWAGO
Websitehttps://www.wago.com/
Environmental Compliance
Download Datasheet Parametric View All

231-632/017-000 Overview

Strip Terminal Block, 15A, 2.5mm2, 1 Row(s), 1 Deck(s),

231-632/017-000 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Other featuresFRONT ENTRY
Fastening methodSPRING LOADED
Installation typeBOARD
Number of layers1
Rows1
Number of channels2
Rated current15 A
Rated voltage300 V
safety certificateUL; CSA
Terminal and terminal strip typesSTRIP TERMINAL BLOCK
Conductor cross section2.5 mm2
Wire gauge14 AWG
Base Number Matches1
Question: Under what circumstances will Failedtohaltcpu appear
Environment: IAR ewarm 5.2 + J-link + stm32 Phenomenon: I just changed ewarm 4.4 to 5.2 today. The program runs normally in simulation and actual operation under 4.4. It runs normally in simulation un...
wangxiaoacc stm32/stm8
How to determine whether a button is long pressed and what operations need to be performed during this process
When a button is long pressed, a data needs to be added during this process. For example, if a number is originally 1, when it is long pressed, the number automatically increases until the button is r...
563876287 Embedded System
Three-phase AC-DC conversion circuit (Question B)
...
buildele Electronics Design Contest
ZTE mobile phone design training materials
ZTE mobile phone design training materials...
simonprince Analog electronics
Why can't I use T/C0 to generate PWM wave and directly change the value of OCR0 to generate different duty cycles?
I am using M16+ ICC V7 to debug the program , AD conversion plus PWM wave. In the program, I directly set an OCR0 value according to the AD value range to change the duty cycle, such as if (ADthe data...
guowj513 Microchip MCU
I use PDA to connect to the Access database, but I always get the following error message. Please help me.
An unhandled exception of type 'System.Runtime.InteropServices.ExternalException' occurred in InTheHand.AdoceNet.dll. Other information: -2147024809 What does -2147024809 mean? I can't find it in the ...
Dream1231 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1346  964  1512  2717  1391  28  20  31  55  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号