EEWORLDEEWORLDEEWORLD

Part Number

Search

RA15WOIS

Description
Rocker Switch, SPST, On-off, Maintained, Solder Lug Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size40KB,1 Pages
ManufacturerOslo Switch Inc
Download Datasheet Parametric View All

RA15WOIS Overview

Rocker Switch, SPST, On-off, Maintained, Solder Lug Terminal, Rocker Actuator, Panel Mount

RA15WOIS Parametric

Parameter NameAttribute value
MakerOslo Switch Inc
Reach Compliance Codeunknow
ECCN codeEAR99
Actuator angle
Actuator colorORANGE
Actuator length0.217 inch
Actuator typeROCKER
Other featuresAPPROVAL: UL
body width13.0048 mm
Body colorWHITE
body height13.0048 mm
Body length or diameter18.5928 mm
Contact (AC) maximum rated R load6A@250VAC
Maximum contact current (AC)6 A
Contact functionON-OFF
Contact resistance0.02 mΩ
Maximum contact voltage (AC)250 V
Dielectric withstand voltage1500VAC V
Electrical life10000 Cycle(s)
Insulation resistance1000000000 Ω
Manufacturer's serial numberRA
Installation featuresPANEL MOUNT
sealMOLDED
surface mountNO
Switch actionMAINTAINED
switch functionSPST
Switch typeROCKER SWITCH
Terminal length0.126 inch
Termination typeSOLDER LUG
RA MINIATURE
ROCKER SWITCHES
Features
Snap-in mounting
Choice of terminals
approval available
Maintained or momentary
Specifications
Rating ..................................... 6A 250V AC
Mechanical Life ...................... 15,000 Cycles
Electrical Life .......................... 10,000 Cycles
Contact Resistance ................ 20mΩ max.
Insulation Resistance ............. 1,000MΩ min.
Dielectric Strength .................. 1,500V AC for 1 Minute
............................................... 3,000V AC between poles
Thickness (mm)
Length (mm)
Thickness (mm)
0.7 ˜ 1.25
1.26 ˜ 2.0
2.1 ˜ 3
Length (mm)
0.7 ˜ 1.25
19.0 + 0.2
1.26 ˜ 2.0
19.3 + 0.2
2.1 ˜ 3
19.6 + 0.2
15
(.591)
15
(.591)
21 (.827)
10
(.394)
5.5 (.217)
2 (.079)
13
(.512)
3.8 (.150)
14
(.551)
18.6
(.732)
Length
4.75 X 0.8
12
(.472)
13
(.512)
7.3
19.0 + 0.2
19.3 + 0.2
19.6 + 0.2
Panel
Cut-Out
13 (.512)
21
(.827)
Ordering Information:
RA
Function
1=SPST;ON/OFF
2=6A,250V DC
2=SPDT;ON/ON
3=SPDT;ON/OFF/ON 5=8A,250V AC
3
15A 125V AC
4=SPDT;ON/(ON)
5=SPST;OFF/(ON)
6=SPDT;(ON)/OFF/(ON)
7=SPST;ON/(OFF)
8=SPDT;ON/OFF/(ON)
Notes:
Housing
Color
0=2A,250V AC
Rating
K=Black
W=White
Rocker
Color
A=
K=Black
W=White
O=Orange B =
R=Red
C=
D=
Marking
F=
G=
0.7 X 2.4
Terminal
Type
14
3.2
0.8 X 1.2
H=
I=
L=
ON
OFF
S Type
P Type
1. Function #3,6 & 8 are available with S Type Terminal only.
2. Mounting hole diagram for P & R Type Terminals:
7.3
E=
4.75 X 0.8
5.5
16
T Type
12
7
.276
14
.551
R Type
3. Functions 1 & 2 only.
Telephone (203) 272-2794
q
Fax (203) 272-3492
25
"Fully Digital Controlled TI Solution Power Supply" Project Division of Work and Progress Report
The following is the division of labor among project team members:Division of Labor Person in charge (sorted by internal code) Job DescriptionAuxiliary power supply jishuaihu, lyzhangxiang Input 310V,...
dontium DIY/Open Source Hardware
How to extract the basic signal of digital sampling signal?
In power applications, digital signal sampling, filtering and fundamental extraction are commonly used methods in design. How to extract the fundamental signal contained in the digital sampling signal...
eeleader Industrial Control Electronics
Electronics Contest Topic Analysis
[i=s]This post was last edited by paulhyde on 2014-9-15 09:23[/i] Analysis of the topic of the electronic competition...
dtcxn Electronics Design Contest
How to get the handle of an already opened device in WINCE6.0
RT, I know the name of the device, but I don't know the handle of the device. Dear seniors, is there any function or method to get the handle of the device when I know the device name? Or by searching...
arkin Embedded System
Please help! Questions about FAT32...
The limit of FAT32 in Windows seems to be 30GB. I have a 60G hard disk, which I formatted into FAT32 using a partition tool (more than 30GB cannot be formatted into FAT32 in Windows). It can also be u...
无域思维 Embedded System
Profibus bus alarm problem
One of the circular processing lines in the unit uses CPU313-2DP as the PLC, with 6 ET200ECO stations and 6 ET200S stations. For a period of time, there was such a phenomenon that the line stopped mov...
jek9528 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 286  200  2003  1105  1576  6  5  41  23  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号