MINIATURE ALUMINUM ELECTROLYTIC CAPACITORS
BG
For PSU, Long Life
Series
Long Life
High reliability withstanding 10000 hours load life at 105 C
For power supply and adapter
Complied to the RoHS directive
Item
Operating temperature range
Leakage current max.
Capacitance tolerance
Dissipation factor max.
(at 120Hz, 20°
C)
Low temperature characteristics
(Impedance ratio at 120Hz)
-25 ~ +105 C
I = 0.02CV+15 A (after 5 minutes)
20% at 120Hz, 20 C
Rated Voltage(V)
tan
WV
Z(-25 C) / Z(+20 C)
Characteristics
400
0.20
400
6
450
0.20
450
6
After an application of DC bias voltage plus the rated AC ripple current for 10000 hours at 105 C.
The measurement shall meet the following limits. The DC voltage plus the peak AC voltage
combined must not exceed the rated voltage.
Load life
Leakage current
Capacitance change
tan
Less than specified value
Within 20% of initial value
Less than 200% of specified value
Shelf life (at 105°
C)
After 1000 hours no load test, leakage current, capacitance and tan are same as load life value.
The measurement shall be performed at 20 C by the KS C 6035 clause 5.4.
Unit : mm
DRAWING
Insulating sleeve
d 0.05 Tinned copper-ply wire
max.
ØD
P
P
0.5
12.5
5.0
0.6
16
7.5
0.8
2.0
0.5
18
7.5
0.8
20
10.0
0.8
3.0
1.0
D
Ød
β
α
L
max.
15 min.
4 min.
Safety vent
DIMENSIONS & MAXIMUM PERMISSIBLE RIPPLE CURRENT
μ
F
22
33
47
68
82
100
120
150
WV
12.5
16
18
18
18
18
18
20
25
20
20
25
31.5
31.5
40
41
400
430
640
840
870
950
1000
1160
1280
12.5
16
18
18
18
18
18
20
25
25
20
25
31.5
35.5
40
41
450
350
650
880
1000
1050
1100
1300
1440
Ripple current (mA rms) at 105 C, 100kHz
Case size D L (mm)
FREQUENCY COEFFICIENT OF PERMISSIBLE RIPPLE CURRENT
Frequency
Coefficient
120Hz
0.50
1kHz
0.80
10kHz
0.90
50kHz
0.95
100kHz≦
1.00
146