C1206T609M4GCL7800

Description
Ceramic Capacitor, Ceramic, 16V, 20% +Tol, 20% -Tol, C0G, -/+30ppm/Cel TC, 0.000006uF, 1206,
CategoryPassive components    capacitor   
File Size147KB,8 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

C1206T609M4GCL7800 Overview

Ceramic Capacitor, Ceramic, 16V, 20% +Tol, 20% -Tol, C0G, -/+30ppm/Cel TC, 0.000006uF, 1206,

C1206T609M4GCL7800 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Objectid711421650
package instruction, 1206
Reach Compliance Codenot_compliant
ECCN codeEAR99
capacitance0.000006 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high0.78 mm
JESD-609 codee0
length3.2 mm
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, Plastic, 7 Inch
positive tolerance20%
Rated (DC) voltage (URdc)16 V
seriesC(SIZE)-COTS
size code1206
Temperature characteristic codeC0G
Temperature Coefficient30ppm/Cel ppm/°C
Terminal surfaceTin/Lead (Sn90Pb10) - with Nickel (Ni) barrier
width1.6 mm
Product Bulletin
Ceramic Commercial-Off-The-Shelf Surface Mount Capacitors (COTS)
KEMET is a qualified supplier of various military and high reliability specifications. The COTS program is an extension
of KEMET's knowledge of high reliability test regimes and requirements. KEMET has for years supplied product that has
been "up-screened" by working with customer drawings and imposing the design and test requirements specified. The COTS
program will offer the same high quality and reliability components "up-screened" to the ordered test level at a lower cost to
the customer. It eliminates the need for customer specific drawings used to achieve the reliability level required for customer
applications. The tests and inspections imposed by the COTS program have been selected to provide the accelerated con-
ditioning and 100% screening to eliminate infant mortal failures from the population.
All COTS testing includes Voltage Conditioning and post electrical testing per MIL-PRF-55681, paragraph 4.8.3.1, Standard
voltage conditioning. For enhanced reliability, KEMET also provides the following test options and conformance certification.
Test Level “A”
Test Level “B”
Test Level “C”
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
PDA 8%
C of C
PDA 8%
DPA
C of C
PDA 8%
DPA
85/85
C of C
• All COTS testing includes
Voltage Conditioning and post
electrical testing per MIL-PRF-
55681
• DPA per EIA-469
• Humidity, steady state, low
voltage (85/85) per MIL-STD
202, Method 103, condition A
• Certificate of Compliance
KEMET COTS MLCC surface mount capacitors are available in standard EIA case sizes from 0402 to 2225 and
standard capacitance values in X7R and C0G dielectrics. Voltage ratings range from 6.3V to 200V. To order the
COTS part number use a T in the 6th digit of the part number in conjunction with the desired test level A, B, or C
in the 13th digit. A Tin/Lead termination option is also available with COTS by using a L in the 14th digit of the
part number. For additional dielectrics and voltage ratings please contact the factory or local Sales personnel.
Applications
Military Products
Space Quality Products
High Reliability Electronics
F-9038B 01/06
How to log in to EEWORLD University TI classroom now?
As the title says: How do I log in now? It prompts me to fill in the information, but it still doesn't work after I finish it. It prompts me that I have already registered....
499362154 Suggestions & Announcements
vxworks6.6 FTP loading error
Using platform vxworks6.6 and development environment worksbench3.0, I added the corresponding FTP macro definitions in the config.h file: #define INCLUDE_IPFTPC #define INCLUDE_IPFTPS When compiling ...
wyh121w Real-time operating system RTOS
DSP reports an error, how to solve it?
DSP链接的时候,报错代码如下:Error connecting to the target:Error 0x00001200/-1031Error during: OCS Device driver: Problem with the Emulation Controller. It is recommended to RESET EMULATOR.This will disconnect ea...
yaking DSP and ARM Processors
uboot transplantation problem
cpu/arm920t/s3c24x0/libs3c24x0.a lib_arm/libarm.a fs/cramfs/libcramfs.a fs/fat/libfat.a fs/fdos/libfdos.a fs/jffs2/libjffs2.a fs/reiserfs/libreiserfs.a fs/ext2/libext2fs.a net/libnet.a disk/libdisk.a ...
hy8457 Embedded System
Good stuff
[i=s]This post was last edited by paulhyde on 2014-9-15 09:26[/i] Dongdong...
363078522 Electronics Design Contest
There are many such problems when packaging. Please help me solve them.
More than 200 errors, I am also drunkWhat should I do? My nodes are all connected? Thank you very much! ! !...
ZNF PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2599  1741  843  2663  2000  53  36  17  54  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号