TECHNICAL SPECIFICATIONS
Technical Data:
Capacitance Range:
Capacitance Tolerance:
Rated Voltage (V
R
)
Category Voltage (V
C
)
Surge Voltage (V
S
)
Surge Voltage (V
S
)
Temperature Range:
Unless otherwise specified, all technical data relate to an ambient temperature of 25°C
0.10 μF to 100 μF
±5%; ±10%; ±20%
4
6
10
15
20
25
35
50
2.7
4
6.7
10
13.3
16.7
23.3
33.3
5.3
8
13.3
20
26.7
33.3
46.7
66.7
3.5
5.3
8.7
13.3
17.8
22.2
31.1
44.5
-55°C to +125°C
≤ 85°C:
≤125°C:
≤ 85°C:
≤125°C:
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
032322
9
–
high reliability tantalum capacitors
–
TAZ SERIES
CWR09 - MIL-PRF-55365/4 Established Reliability,
COTS-Plus & Space Level
Parametric Specifications by Rating per MIL-PRF-55365/4
ESR
DCL max
DF Max
DC Rated
@
+(85/125)
Voltage
+25ºC
+85ºC
+125ºC
+25ºC
100kHz
ºC
V
Ohms
@ +85ºC @ +25ºC
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
20
45
12
8
8
5.5
4
3.5
2.2
1.1
0.9
8
8
5.5
4.5
3.5
2.2
1.1
0.9
50
50
10
10
8
5.5
4.5
3.5
2.5
1.1
0.9
12
8
5.5
5
4
2.5
1.1
0.9
14
10
12
6
5
4
2.4
1.1
0.9
(μA)
1
1
1
1
1
1
1
2
3
4
1
1
1
1
1
2
3
4
1
1
1
1
1
1
1
1
2
3
5
1
1
1
1
1
2
4
5
1
1
1
1
1
1
2
3
4
(μA)
10
10
10
10
10
10
10
20
30
40
10
10
10
10
10
20
30
40
10
10
10
10
10
10
10
10
20
30
50
10
10
10
10
10
20
40
50
10
10
10
10
10
10
20
30
40
(μA)
12
12
12
12
12
12
12
24
36
48
12
12
12
12
12
24
36
48
12
12
12
12
12
12
12
12
24
36
60
12
12
12
12
12
24
48
60
12
12
12
12
12
12
24
36
48
(%)
6
6
6
6
6
8
8
8
10
10
6
6
6
6
8
8
10
10
6
6
6
6
6
6
6
6
8
10
10
6
6
6
6
6
6
6
8
8
6
6
6
6
6
6
6
6
(%)
8
8
8
8
8
8
10
10
12
12
8
8
8
8
10
10
12
12
8
8
8
8
8
8
8
8
8
12
12
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Typical RMS Ripple Data by Rating
-55ºC
(%)
8
8
8
8
8
10
12
12
12
12
8
8
8
8
12
12
12
12
8
8
8
8
8
8
8
8
10
12
12
8
8
8
8
8
8
8
10
10
8
8
8
8
8
8
8
8
Power
Dissipation
W
0.030
0.030
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.030
0.030
0.030
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.050
0.070
0.070
0.075
0.080
0.090
0.100
0.125
0.150
25ºC
Ripple
A
(100kHz)
0.03
0.05
0.08
0.09
0.12
0.14
0.16
0.21
0.34
0.41
0.08
0.09
0.12
0.13
0.16
0.21
0.34
0.41
0.02
0.02
0.05
0.07
0.09
0.12
0.13
0.16
0.20
0.34
0.41
0.06
0.09
0.12
0.13
0.15
0.20
0.34
0.41
0.06
0.08
0.08
0.11
0.13
0.15
0.20
0.34
0.41
85ºC
Ripple
125ºC
Ripple
25ºC
Ripple
85ºC
Ripple
125ºC
Ripple
RATING & PART NUMBER REFERENCE
CWR09 P/N
MIL & COTS-Plus P/N
TAZ R 334 * 004 C
#
@
0 ^ ++
TAZ R 225 * 004 C
#
@
0 ^ ++
TAZ A 225 * 004 C
#
@
0 ^ ++
TAZ B 475 * 004 C
#
@
0 ^ ++
TAZ C 685 * 004 C
#
@
0 ^ ++
TAZ D 106 * 004 C
#
@
0 ^ ++
TAZ E 156 * 004 C
#
@
0 ^ ++
TAZ F 336 * 004 C
#
@
0 ^ ++
TAZ G 686 * 004 C
#
@
0 ^ ++
TAZ H 107 * 004 C
#
@
0 ^ ++
TAZ A 155 * 006 C
#
@
0 ^ ++
TAZ B 335 * 006 C
#
@
0 ^ ++
TAZ C 475 * 006 C
#
@
0 ^ ++
TAZ D 685 * 006 C
#
@
0 ^ ++
TAZ E 106 * 006 C
#
@
0 ^ ++
TAZ F 226 * 006 C
#
@
0 ^ ++
TAZ G 476 * 006 C
#
@
0 ^ ++
TAZ H 686 * 006 C
#
@
0 ^ ++
TAZ R 334 * 010 C
#
@
0 ^ ++
TAZ R 474 * 010 C
#
@
0 ^ ++
TAZ R 105 * 010 C
#
@
0 ^ ++
TAZ A 105 * 010 C
#
@
0 ^ ++
TAZ B 225 * 010 C
#
@
0 ^ ++
TAZ C 335 * 010 C
#
@
0 ^ ++
TAZ D 475 * 010 C
#
@
0 ^ ++
TAZ E 685 * 010 C
#
@
0 ^ ++
TAZ F 156 * 010 C
#
@
0 ^ ++
TAZ G 336 * 010 C
#
@
0 ^ ++
TAZ H 476 * 010 C
#
@
0 ^ ++
TAZ A 684 * 015 C
#
@
0 ^ ++
TAZ B 155 * 015 C
#
@
0 ^ ++
TAZ C 225 * 015 C
#
@
0 ^ ++
TAZ D 335 * 015 C
#
@
0 ^ ++
TAZ E 475 * 015 C
#
@
0 ^ ++
TAZ F 106 * 015 C
#
@
0 ^ ++
TAZ G 226 * 015 C
#
@
0 ^ ++
TAZ H 336 * 015 C
#
@
0 ^ ++
TAZ A 474 * 020 C
#
@
0 ^ ++
TAZ B 684 * 020 C
#
@
0 ^ ++
TAZ B 105 * 020 C
#
@
0 ^ ++
TAZ C 155 * 020 C
#
@
0 ^ ++
TAZ D 225 * 020 C
#
@
0 ^ ++
TAZ E 335 * 020 C
#
@
0 ^ ++
TAZ F 685 * 020 C
#
@
0 ^ ++
TAZ G 156 * 020 C
#
@
0 ^ ++
TAZ H 226 * 020 C
#
@
0 ^ ++
SRC9000 P/N
Case
R
R
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
R
R
R
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
B
C
D
E
F
G
H
Cap
@ 120Hz
μF
@ 25ºC
0.33
2.2
2.2
4.7
6.8
10
15
33
68
100
1.5
3.3
4.7
6.8
10
22
47
68
0.33
0.47
1
1
2.2
3.3
4.7
6.8
15
33
47
0.68
1.5
2.2
3.3
4.7
10
22
33
0.47
0.68
1
1.5
2.2
3.3
6.8
15
22
A
A
V
V
V
(100kHz) (100kHz) (100kHz) (100kHz) (100kHz)
0.02
0.05
0.07
0.08
0.11
0.13
0.14
0.19
0.30
0.37
0.07
0.08
0.11
0.12
0.14
0.19
0.30
0.37
0.02
0.02
0.05
0.06
0.08
0.11
0.12
0.14
0.18
0.30
0.37
0.06
0.08
0.11
0.11
0.14
0.18
0.30
0.37
0.05
0.08
0.07
0.10
0.11
0.14
0.18
0.30
0.37
0.01
0.02
0.03
0.04
0.05
0.06
0.06
0.09
0.13
0.16
0.03
0.04
0.05
0.05
0.06
0.09
0.13
0.16
0.01
0.01
0.02
0.03
0.04
0.05
0.05
0.06
0.08
0.13
0.16
0.03
0.04
0.05
0.05
0.06
0.08
0.13
0.16
0.02
0.03
0.03
0.04
0.05
0.06
0.08
0.13
0.16
1.16
0.60
0.63
0.75
0.64
0.57
0.56
0.47
0.37
0.37
0.63
0.75
0.64
0.60
0.56
0.47
0.37
0.37
1.22
1.22
0.55
0.71
0.75
0.64
0.60
0.56
0.50
0.37
0.37
0.77
0.75
0.64
0.63
0.60
0.50
0.37
0.37
0.84
0.84
0.92
0.67
0.63
0.60
0.49
0.37
0.37
1.05
0.54
0.57
0.67
0.58
0.51
0.51
0.42
0.33
0.33
0.57
0.67
0.58
0.54
0.51
0.42
0.33
0.33
1.10
1.10
0.49
0.64
0.67
0.58
0.54
0.51
0.45
0.33
0.33
0.70
0.67
0.58
0.57
0.54
0.45
0.33
0.33
0.75
0.75
0.82
0.60
0.57
0.54
0.44
0.33
0.33
0.46
0.24
0.25
0.30
0.26
0.23
0.22
0.19
0.15
0.15
0.25
0.30
0.26
0.24
0.22
0.19
0.15
0.15
0.49
0.49
0.22
0.28
0.30
0.26
0.24
0.22
0.20
0.15
0.15
0.31
0.30
0.26
0.25
0.24
0.20
0.15
0.15
0.33
0.33
0.37
0.27
0.25
0.24
0.20
0.15
0.15
CWR09C^225*@+
CWR09C^475*@+
CWR09C^685*@+
CWR09C^106*@+
CWR09C^156*@+
CWR09C^336*@+
CWR09C^686*@+
CWR09C^107*@+
CWR09D^155*@+
CWR09D^335*@+
CWR09D^475*@+
CWR09D^685*@+
CWR09D^106*@+
CWR09D^226*@+
CWR09D^476*@+
CWR09D^686*@+
TAZ A 225 * 004 C
L
@
9 ^ ++
TAZ B 475 * 004 C
L
@
9 ^ ++
TAZ C 685 * 004 C
L
@
9 ^ ++
TAZ D 106 * 004 C
L
@
9 ^ ++
TAZ E 156 * 004 C
L
@
9 ^ ++
TAZ F 336 * 004 C
L
@
9 ^ ++
TAZ G 686 * 004 C
L
@
9 ^ ++
TAZ H 107 * 004 C
L
@
9 ^ ++
TAZ A 155 * 006 C
L
@
9 ^ ++
TAZ B 335 * 006 C
L
@
9 ^ ++
TAZ C 475 * 006 C
L
@
9 ^ ++
TAZ D 685 * 006 C
L
@
9 ^ ++
TAZ E 106 * 006 C
L
@
9 ^ ++
TAZ F 226 * 006 C
L
@
9 ^ ++
TAZ G 476 * 006 C
L
@
9 ^ ++
TAZ H 686 * 006 C
L
@
9 ^ ++
CWR09F^105*@+
CWR09F^225*@+
CWR09F^335*@+
CWR09F^475*@+
CWR09F^685*@+
CWR09F^156*@+
CWR09F^336*@+
CWR09F^476*@+
CWR09H^684*@+
CWR09H^155*@+
CWR09H^225*@+
CWR09H^335*@+
CWR09H^475*@+
CWR09H^106*@+
CWR09H^226*@+
CWR09H^336*@+
CWR09J^474*@+
CWR09J^684*@+
CWR09J^105*@+
CWR09J^155*@+
CWR09J^225*@+
CWR09J^335*@+
CWR09J^685*@+
CWR09J^156*@+
CWR09J^226*@+
TAZ A 105 * 010 C
L
@
9 ^ ++
TAZ B 225 * 010 C
L
@
9 ^ ++
TAZ C 335 * 010 C
L
@
9 ^ ++
TAZ D 475 * 010 C
L
@
9 ^ ++
TAZ E 685 * 010 C
L
@
9 ^ ++
TAZ F 156 * 010 C
L
@
9 ^ ++
TAZ G 336 * 010 C
L
@
9 ^ ++
TAZ H 476 * 010 C
L
@
9 ^ ++
TAZ A 684 * 015 C
L
@
9 ^ ++
TAZ B 155 * 015 C
L
@
9 ^ ++
TAZ C 225 * 015 C
L
@
9 ^ ++
TAZ D 335 * 015 C
L
@
9 ^ ++
TAZ E 475 * 015 C
L
@
9 ^ ++
TAZ F 106 * 015 C
L
@
9 ^ ++
TAZ G 226 * 015 C
L
@
9 ^ ++
TAZ H 336 * 015 C
L
@
9 ^ ++
TAZ A 474 * 020 C
L
@
9 ^ ++
TAZ B 684 * 020 C
L
@
9 ^ ++
TAZ B 105 * 020 C
L
@
9 ^ ++
TAZ C 155 * 020 C
L
@
9 ^ ++
TAZ D 225 * 020 C
L
@
9 ^ ++
TAZ E 335 * 020 C
L
@
9 ^ ++
TAZ F 685 * 020 C
L
@
9 ^ ++
TAZ G 156 * 020 C
L
@
9 ^ ++
TAZ H 226 * 020 C
L
@
9 ^ ++
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: KYOCERA AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
10
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
062620
–
high reliability tantalum capacitors
–
TAZ SERIES
CWR09 - MIL-PRF-55365/4 Established Reliability,
COTS-Plus & Space Level
RATING & PART NUMBER REFERENCE
CWR09 P/N
CWR09K^334*@+
CWR09K^684*@+
CWR09K^105*@+
CWR09K^155*@+
CWR09K^225*@+
CWR09K^475*@+
CWR09K^685*@+
CWR09K^106*@+
CWR09K^156*@+
CWR09M^224*@+
CWR09M^474*@+
CWR09M^684*@+
CWR09M^105*@+
CWR09M^155*@+
CWR09M^335*@+
CWR09M^475*@+
CWR09M^685*@+
CWR09N^104*@+
CWR09N^154*@+
CWR09N^224*@+
CWR09N^334*@+
CWR09N^474*@+
CWR09N^684*@+
CWR09N^105*@+
CWR09N^155*@+
CWR09N^225*@+
CWR09N^335*@+
CWR09N^475*@+
MIL & COTS-Plus P/N
TAZ A 334 * 025 C
#
@
0 ^ ++
TAZ B 684 * 025 C
#
@
0 ^ ++
TAZ C 105 * 025 C
#
@
0 ^ ++
TAZ D 155 * 025 C
#
@
0 ^ ++
TAZ E 225 * 025 C
#
@
0 ^ ++
TAZ F 475 * 025 C
#
@
0 ^ ++
TAZ G 685 * 025 C
#
@
0 ^ ++
TAZ G 106 * 025 C
#
@
0 ^ ++
TAZ H 156 * 025 C
#
@
0 ^ ++
TAZ A 224 * 035 C #
@
0 ^ ++
TAZ B 474 * 035 C #
@
0 ^ ++
TAZ C 684 * 035 C #
@
0 ^ ++
TAZ D 105 * 035 C #
@
0 ^ ++
TAZ E 155 * 035 C #
@
0 ^ ++
TAZ F 335 * 035 C #
@
0 ^ ++
TAZ G 475 * 035 C #
@
0 ^ ++
TAZ H 685 * 035 C #
@
0 ^ ++
TAZ A 104 * 050 C #
@
0 ^ ++
TAZ A 154 * 050 C #
@
0 ^ ++
TAZ B 224 * 050 C #
@
0 ^ ++
TAZ B 334 * 050 C #
@
0 ^ ++
TAZ C 474 * 050 C #
@
0 ^ ++
TAZ D 684 * 050 C #
@
0 ^ ++
TAZ E 105 * 050 C #
@
0 ^ ++
TAZ F 155 * 050 C #
@
0 ^ ++
TAZ F 225 * 050 C #
@
0 ^ ++
TAZ G 335 * 050 C #
@
0 ^ ++
TAZ H 475 * 050 C #
@
0 ^ ++
SRC9000 P/N
TAZ A 334 * 025 C
L
@
9 ^ ++
TAZ B 684 * 025 C
L
@
9 ^ ++
TAZ C 105 * 025 C
L
@
9 ^ ++
TAZ D 155 * 025 C
L
@
9 ^ ++
TAZ E 225 * 025 C
L
@
9 ^ ++
TAZ F 475 * 025 C
L
@
9 ^ ++
TAZ G 685 * 025 C
L
@
9 ^ ++
TAZ G 106 * 025 C
L
@
9 ^ ++
TAZ H 156 * 025 C
L
@
9 ^ ++
TAZ A 224 * 035 C L
@
9 ^ ++
TAZ B 474 * 035 C L
@
9 ^ ++
TAZ C 684 * 035 C L
@
9 ^ ++
TAZ D 105 * 035 C L
@
9 ^ ++
TAZ E 155 * 035 C L
@
9 ^ ++
TAZ F 335 * 035 C L
@
9 ^ ++
TAZ G 475 * 035 C L
@
9 ^ ++
TAZ H 685 * 035 C L
@
9 ^ ++
TAZ A 104 * 050 C L
@
9 ^ ++
TAZ A 154 * 050 C L
@
9 ^ ++
TAZ B 224 * 050 C L
@
9 ^ ++
TAZ B 334 * 050 C L
@
9 ^ ++
TAZ C 474 * 050 C L
@
9 ^ ++
TAZ D 684 * 050 C L
@
9 ^ ++
TAZ E 105 * 050 C L
@
9 ^ ++
TAZ F 155 * 050 C L
@
9 ^ ++
TAZ F 225 * 050 C L
@
9 ^ ++
TAZ G 335 * 050 C L
@
9 ^ ++
TAZ H 475 * 050 C L
@
9 ^ ++
Case
A
B
C
D
E
F
G
G
H
A
B
C
D
E
F
G
H
A
A
B
B
C
D
E
F
F
G
H
Cap
@ 120Hz
μF
@ 25ºC
0.33
0.68
1
1.5
2.2
4.7
6.8
10
15
0.22
0.47
0.68
1
1.5
3.3
4.7
6.8
0.1
0.15
0.22
0.33
0.47
0.68
1
1.5
2.2
3.3
4.7
Parametric Specifications by Rating per MIL-PRF-55365/4
ESR
DCL max
DF Max
DC Rated
@
+(85/125)
Voltage
+25ºC
+85ºC
+125ºC
+25ºC
100kHz
ºC
V
Ohms
@ +85ºC @ +25ºC
25
25
25
25
25
25
25
25
25
35
35
35
35
35
35
35
35
50
50
50
50
50
50
50
50
50
50
50
15
7.5
6.5
6.5
3.5
2.5
1.2
1.4
1
18
10
8
6.5
4.5
2.5
1.5
1.3
22
17
14
12
8
7
6
4
2.5
2
1.5
(μA)
1
1
1
1
1
2
2
3
4
1
1
1
1
1
1
2
3
1
1
1
1
1
1
1
1
2
2
3
(μA)
10
10
10
10
10
20
20
30
40
10
10
10
10
10
10
20
30
10
10
10
10
10
10
10
10
20
20
30
(μA)
12
12
12
12
12
24
24
36
48
12
12
12
12
12
12
24
36
12
12
12
12
12
12
12
12
24
24
36
(%)
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
(%)
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Typical RMS Ripple Data by Rating
-55ºC
(%)
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Power
Dissipation
W
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.125
0.150
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.050
0.050
0.070
0.070
0.075
0.080
0.090
0.100
0.100
0.125
0.150
25ºC
Ripple
A
(100kHz)
0.06
0.10
0.11
0.11
0.16
0.20
0.32
0.30
0.39
0.05
0.08
0.10
0.11
0.14
0.20
0.29
0.34
0.05
0.05
0.07
0.08
0.10
0.11
0.12
0.16
0.20
0.25
0.32
85ºC
Ripple
125ºC
Ripple
25ºC
Ripple
85ºC
Ripple
125ºC
Ripple
A
A
V
V
V
(100kHz) (100kHz) (100kHz) (100kHz) (100kHz)
0.05
0.09
0.10
0.10
0.14
0.18
0.29
0.27
0.35
0.05
0.08
0.09
0.10
0.13
0.18
0.26
0.31
0.04
0.05
0.06
0.07
0.09
0.10
0.11
0.14
0.18
0.23
0.28
0.02
0.04
0.04
0.04
0.06
0.08
0.13
0.12
0.15
0.02
0.03
0.04
0.04
0.06
0.08
0.12
0.14
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.06
0.08
0.10
0.13
0.87
0.72
0.70
0.72
0.56
0.50
0.39
0.42
0.39
0.95
0.84
0.77
0.72
0.64
0.50
0.43
0.44
1.05
0.92
0.99
0.92
0.77
0.75
0.73
0.63
0.50
0.50
0.47
0.78
0.65
0.63
0.65
0.51
0.45
0.35
0.38
0.35
0.85
0.75
0.70
0.65
0.57
0.45
0.39
0.40
0.94
0.83
0.89
0.82
0.70
0.67
0.66
0.57
0.45
0.45
0.43
0.35
0.29
0.28
0.29
0.22
0.20
0.15
0.17
0.15
0.38
0.33
0.31
0.29
0.25
0.20
0.17
0.18
0.42
0.37
0.40
0.37
0.31
0.30
0.29
0.25
0.20
0.20
0.19
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: KYOCERA AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
062620
11
–
high reliability tantalum capacitors
–
TAZ SERIES
CWR19 - MIL-PRF-55365/11 Established Reliability,
COTS-Plus & Space Level
An extended range of capacitor ratings beyond
CWR09 that is fully qualified to MIL-PRF-55365/11,
this series represents the most flexible of surface
mount form factors, offering nine case sizes (the
original A through H of CWR09) and adds the new
X case size.
The molded body / compliant termination
construction ensures no TCE mismatch with any
substrate. This construction is compatible with
a wide range of SMT board assembly processes
including convection reflow solder, conductive epoxy
or compression bonding techniques. The parts also
carry full polarity and capacitance / voltage marking.
The four smaller cases are characterized by their low
profile construction, with the A case being the world’s
smallest molded military tantalum chip.
The series is qualified to MIL-PRF-55365 Weibull
“B”, “C”, “D” and “T” levels, with all surge options
(“A”, “B” & “C”) available.
For Space Level applications, SRC 9000
qualification is recommended (see ratings table
for part number availability).
There are four termination finishes available:
solder plated, fused solder plated, hot solder
dipped and gold plated (these are “H”, “K”, “C” and
“B” termination, respectively, per MIL-PRF-55365).
In addition, the molding compound has been
selected to meet the requirements of UL94V-0
(Flame Retardancy) and outgassing requirements
of ASTM E-595.
For moisture sensitivity levels please refer to the High
Reliability Tantalum MSL section located in the back
of the High Reliability Tantalum Catalog.
CASE DIMENSIONS:
Case
Code
Length (L)
±0.38
(0.015)
Width (W)
±0.38
(0.015)
Height (H)
±0.38
(0.015)
Term. Width
(W
1
)
1.27±0.13
(0.050±0.005)
1.27±0.13
(0.050±0.005)
1.27±0.13
(0.050±0.005)
2.41+0.13/-0.25
(0.095+0.005/-0.010)
2.41+0.13/-0.25
(0.095+0.005/-0.010)
3.30±0.13
(0.130±0.005)
2.67±0.13
(0.105±0.005)
3.68+0.13/-0.51
(0.145+0.005/-0.020)
3.05±0.13
(0.120±0.005)
millimeters (inches)
Term. Length (A)
+0.25/-0.13
(+0.010/-0.005)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
1.27 (0.050)
1.27 (0.050)
1.19 (0.047)
S min
0.38 (0.015)
1.65 (0.065)
2.92 (0.115)
1.65 (0.065)
2.92 (0.115)
3.43 (0.135)
3.56 (0.140)
4.06 (0.160)
3.67 (0.144)
Typical
Weight (g)
0.016
0.025
0.035
0.045
0.065
0.125
0.205
0.335
0.420
MARKING
(White marking on black body)
Polarity Stripe (+)
Capacitance Code
Rated Voltage
A
B
C
D
E
F
G
H
X
2.54 (0.100) 1.27 (0.050) 1.27 (0.050)
3.81 (0.150) 1.27 (0.050) 1.27 (0.050)
5.08 (0.200) 1.27 (0.050) 1.27 (0.050)
3.81 (0.150) 2.54 (0.100) 1.27 (0.050)
5.08 (0.200) 2.54 (0.100) 1.27 (0.050)
5.59 (0.220) 3.43 (0.135) 1.78 (0.070)
6.73 (0.265) 2.79 (0.110)
7.24 (0.285) 3.81 (0.150)
6.93 (0.273) 5.41 (0.213)
2.79 (0.110)
2.79 (0.110)
2.74 (0.108)
CWR19-MIL-PRF 55365/11
CAPACITANCE AND RATED VOLTAGE, V
R
(VOLTAGE CODE) RANGE (LETTER DENOTES CASE SIZE)
Capacitance
µF
0.33
0.47
0.68
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
150
220
330
Code
334
474
684
105
155
225
335
475
685
106
156
226
336
476
686
107
157
227
337
4V (C)
6V (D)
Rated Voltage DC (V
R
) at 85ºC
10V (F)
15V (H)
20V (J)
25V (K)
A
B
D
E
F
G
G/H
H/X
G
H
X
35V (M)
A
A
A
A
B
B
B/D
D/E
E
E
F
G
H
H
A
A
B
B
B/D/E
D/E
E
F
F/G
G
G
H
H
A
A
B/C
B/C/D
B/C/D/E
D/E
E
F
F/G
G
G/H
H/X
H
A
A
A
B
B/C/D
D/E
D/E
E/F
F
F/G
G/H
G/H
H
A
A
B
B
D
E
E
E/F
F
G
H
H/X
12
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
A universal circuit board is a printed circuit board that is covered with pads according to the standard IC spacing (2.54mm) and can be plugged with components and wired as desired, commonly known as ...
The requirement is to read a bitmap from the local computer and display it in the picture control. Because the size of the bitmap is uncertain, the image should be scaled. What method should be used t...
Today, the long-awaited new version of the forum is finally online. It has changed a lot compared to the previous beta version, and the forum now has a lot of new content. However, the existence of bu...
My wiring RMII_TXD0/RMII_TXD1 is strictly a differential pair and is the same length as RMII_TXD_EN, RMII_RXD0/RMII_RXD1 is also strictly a differential pair and is the same length as RMII_RX_DV. Howe...
——Talking about the road to liberating IC designersOn September 15, 2006, the original Protel tool developer, Australian Altium, joined hands with China's first-level general agent, Yidao Electronic T...
introduction
1 The significance of using RTOS on MSP430
It is understandable that it is meaningless to use RTOS on MSP430. Because the hardware resources of MSP430 are limited (for exampl...[Details]
0. Introduction
In daily life, we often see some special-purpose vehicles. When these vehicles pass through intersections, they often obtain the right of way at intersections by temporarily op...[Details]
Due to the significant increase in electronic devices in automotive and industrial applications, the automotive and industrial markets continue to play an important role in China's electronics in...[Details]
Editor's note: In order to help technicians or engineers who have knowledge of PIC microcontroller assembly language quickly master the method of using C language to program PIC microcontrollers, t...[Details]
1 Introduction
Building Automation System (BAS) is a distributed monitoring system (DCS) designed according to distributed information and control theory. It is the result of the mutual de...[Details]
1 Introduction
With the development of control, computer, communication, network technology, etc., a new control technology, namely fieldbus, has emerged in the field of industrial control...[Details]
With the rapid development of intelligent control technology, computers and information technology, the trend of information appliances IA (Information Application), computers and communications integ...[Details]
With the advocacy and implementation of the government's Safe City Plan, the security market has increasingly higher requirements for the clarity of surveillance images. Imagine that after a case o...[Details]
VP2188 is a color STN LCD module produced by Jingdian Pengyuan. This module is a dot matrix transmissive color STN display screen with a color scale of 65 k colors and white LED backlight. Its core...[Details]
OC faults may be the most frequent and the most frequent of all faults in the inverter. They alarm during the startup process, during the shutdown process, during operation, and even when powered o...[Details]
Preface
In recent years, white light LEDs have gradually replaced incandescent bulbs and fluorescent lamps because they have unparalleled advantages over traditional light sources in terms...[Details]
0 Introduction
With the rapid development of social economy and science and technology, electric locomotives, subways and electric vehicles will be widely used. The power conversion and cont...[Details]
1 Overview
In the field of traditional lighting, the concepts and definitions of lamps and lamps are clear. Lamps and lamps have their own applicable product standards, supporting technical st...[Details]
LED is now known as the fourth generation of light sources. High-power LED has many advantages over traditional light sources in outdoor lighting.
1 LED lamps have high light efficiency
C...[Details]
a. Keep the battery clean, wipe off the spilled electrolyte, contaminated dirt and dust in time; keep the poles and terminal clamps clean and in good contact, and apply vaseline or butter to preven...[Details]