EEWORLDEEWORLDEEWORLD

Part Number

Search

2649LP/2C23608L110V/6

Description
Rocker Switch, DPDT, Latched, 10A, 12VDC, Solder/quick Connect Terminal, Concave Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size229KB,8 Pages
ManufacturerAPEM
Environmental Compliance
Download Datasheet Parametric View All

2649LP/2C23608L110V/6 Overview

Rocker Switch, DPDT, Latched, 10A, 12VDC, Solder/quick Connect Terminal, Concave Rocker Actuator, Panel Mount

2649LP/2C23608L110V/6 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator typeCONCAVE ROCKER
body width18.5 mm
body height28.1 mm
Body length or diameter32 mm
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@12VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)12 V
Electrical life10000 Cycle(s)
illuminationRED LAMP
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
method of packingBULK
sealDUST PROOF; WATER PROOF
surface mountNO
Switch actionLATCHED
switch functionDPDT
Switch typeROCKER SWITCH
Termination typeSOLDER/QUICK CONNECT
Base Number Matches1
2600 series
Illuminated and non-illuminated rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max. at 1A 2VDC
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +125°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-49
Ask a question about 430 algorithm
Can I use 430 to do FFT?If so, how many points can it do?It has real-time requirements, it can't be too slow, it must be completed in 125nu. I don't know if 1024 points can be achieved?...
1204 Microcontroller MCU
Problems with adding an intermediate layer in protel99
No signal or plane layer has been selected The error is as above. Can anyone explain it?...
huyanlong Embedded System
The driver was loaded successfully, but the uninstallation failed!
[code] //SOURCES TARGETNAME=hello TARGETPATH=obj TARGETTYPE=DRIVER SOURCES=hello.c//hello.c void StartSrv() {char namebuf[256];memset(namebuf, 0, sizeof(namebuf));SC_HANDLE hMgr, hCS, hOS;GetCurrentDi...
phlelp Embedded System
[Newbie's question] Why can the 319K target file compiled by CCS be loaded into the 32K FLASH?
[Newbie's question] When using CCS to compile the eZ430 Chronos project, the generated target file ez430_chronos_915MHz.out has 319K. Why can it be loaded into the 32K FLASH?A few days ago, I was play...
FreeBlues Microcontroller MCU
Renesas R7F0C80212 board - Generate pwm using code generator
I have been using code generator these days. I am very good at setting ADC and IO ports because it is very simple to use. However, there is a problem when using PWM. After setting it up, the simulated...
flyword Renesas Electronics MCUs
Do you grow desktop plants?
[size=4][color=#006400]Do you raise plants? Post yours in the comments so that everyone can see it! It can also be used as a reference for friends who are interested in raising plants[/color][/size]:)...
eric_wang Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 603  1345  953  446  2061  13  28  20  9  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号