Parallel - 3Rd Overtone Quartz Crystal, 24.576MHz Nom,
CategoryPassive components    Crystal/resonator   
File Size87KB,2 Pages
ManufacturerCTS
Environmental Compliance
Download Datasheet Parametric View All

HG53424CT35GCT Overview

Parallel - 3Rd Overtone Quartz Crystal, 24.576MHz Nom,

HG53424CT35GCT Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid2078848370
Reach Compliance Codecompliant
YTEOL7.13
Other featuresAT-CUT; TR, 7 INCH
Ageing5 PPM/YEAR
Crystal/Resonator TypePARALLEL - 3RD OVERTONE
Drive level10 µW
frequency stability0.005%
frequency tolerance30 ppm
JESD-609 codee4
load capacitance16 pF
Installation featuresSURFACE MOUNT
Nominal operating frequency24.576 MHz
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
physical sizeL5.0XB3.2XH1.3 (mm)/L0.197XB0.126XH0.051 (inch)
Series resistance150 Ω
surface mountYES
Terminal surfaceGold (Au) - with Nickel (Ni) barrier
Crystal – Industrial Electronics
FEATURES
Standard 5.0mm x 3.2mm Glass Seal Package
Fundamental Crystal Design
Frequency Range 8 – 40 MHz Fundamental, 24 – 120 MHz 3
rd
Overtone
Frequency Tolerance; ±20 ppm, ±30 ppm and ± 50 ppm
Frequency Stability, reference Ordering Information
Operating Temperature, -40°C to +125°C standard
Tape & Reel Packaging Standard, EIA-481
RoHS Compliant in Accordance with EU Directive 2011/65/EU
- Lead-Free Termination Finish
- Exemption 7(c)-I, Electrical and electronic components containing lead [Pb] in glass
Model HG534
APPLICATIONS
Model HG534 is a low cost crystal developed for use in industrial applications requiring
extended temperature ranges.
ORDERING INFORMATION
HG534
FREQUENCY
Product Frequency Code
[Refer to document 016-1454-0.]
PACKAGING OPTIONS
T - 1k pcs./reel
R - 3k pcs./reel
LOAD CAPACITANCE
A = 10 pF
G = 30 pF
B = 13 pF
H = 32 pF
C = 16 pF
J = 9 pF
D = 18 pF
K = 8 pF
E = 20 pF
L = 12 pF
F = 24 pF
S = Series
TEMPERATURE RANGE OPTIONS
I = -40°C to +85°C
[All Stability Codes]
G = -40°C to +105°C
[Stability Code 3, 5, 6, 7]
H = -40°C to +125°C
[Stability Code 5, 6, 7]
N = -40°C to +150°C
[Stability Code 6, 7]
MODE OF OSCILLATION
F = Fundamental
T = 3
rd
Overtone
FREQUENCY TOLERANCE @ 25°C
2 = ± 20 ppm
3 = ± 30 ppm
5 = ± 50 ppm
STABILITY TOLERANCE
Over Operating Temperature Range
(Referenced to 25°C Reading)
X = ± 15 ppm
2 = ± 20 ppm
3 = ± 30 ppm
5 = ± 50 ppm
6 = ± 100 ppm
7 = ± 150 ppm
Not all performance combinations and frequencies may be available.
Contact your local CTS Representative or CTS Customer Service for availability.
PACKAGING INFORMATION
DIMENSIONS IN MILLIMETERS
[Reference]
17.5
Ø13.5
2.0
Device quantity is 1k pcs. minimum and 3k pcs. maximum per 180mm reel.
4.0
8.0
Ø1.50
1.75
1.95
120°
Ø60
Ø180
5.40
12.0
Ø21.4
3.5
DIRECTION OF FEED
Document No. 008-0487-0
Page 1- 2
Rev. A
www.ctscorp.com
A new color image reading sensor chip
This paper introduces a new color image reading sensor chip based on CMOS technology and its internal working mechanism. When reading color image information, this chip can improve the problem of poor...
zzzzer16 Test/Measurement
Problem reading eeprom data
The simulated GPS data is stored before 2302251605157148.7035912330.1006250.000309.62. After reading, it is 2302251605157148.7035912330.1006350.000309.62. 10062 becomes 10063. 3 is the data I wrote in...
那是我的最爱 Real-time operating system RTOS
Linux Device Drivers (Chinese 3rd Edition) 2.6 Kernel
Linux Device Drivers (Chinese 3rd Edition) 2.6 Kernel...
呱呱 Linux and Android
How to realize TimerB.OUT1 automatically starts multi-channel multiple AD sampling?
/*Timer B is used to start AD sampling at a fixed time*/TBCTL = TBSSEL1 + TBCLR;TBCCR0 = SMCLK / (SAMPLES); /*1600 sampling points*/TBCCR1 = 200;TBCCTL1 = OUTMOD_7; /*OUT1=1 when TBR = CCR0; OUT1=0 wh...
swustboy Microcontroller MCU
PLC analog frequency conversion acceleration and deceleration control
Make PLC simulate the inverter acceleration and deceleration control. For example, set a data 300 in D200, start PLC, the memory value increases from 0 to 300, the time can be set by yourself, and the...
eeleader Industrial Control Electronics
Why does water absorb almost all microwave frequencies?
This is because the loss angle cotangent of seawater is very large, and the propagation loss of microwaves in it is very large. However, for low frequencies, the loss is much less, so if submarines us...
JasonYoo RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1247  1190  1594  1720  2838  26  24  33  35  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号