HS103DR Series Assemblies
•
55 amp AC output @ 40°C
•
Single Channel or 3 Phase output
•
3 to 32 VDC input control voltage
•
DIN Rail mounted
•
UL, CSA, VDE, CE approved SSRs
PRODUCT SELECTION
Description
3-32 VDC Control
55 A
HS103DR-D2490
55 A
HS103DR-HD6090
55 A
HS103DR-D53TP25D
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
Maximum Load Current [Arms]
Minimum Load Current [Arms]
Maximum Surge Current (16.6ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Maximum I²t for Fusing (8.3 msec) [A² sec]
Minimum Power Factor (with Maximum Load)
HS103DR-D2490
24-280
600
10
500
55
0.04
1200
1.6
6000
0.5
HS103DR-HD6090
48-660
1200
10
500
55
0.04
1200
1.7
6000
0.5
HS103DR-D53TP25D
48-530
1200
10
500
55
0.05
250
1.6
260
0.5
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Maximum Reverse Voltage
Typical Input Current
Nominal Input Impeadance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
HS103DR-D2490
3-32 VDC
3.0 VDC
1.0 VDC
32 VDC
3.4 mA @ 5 VDC
1500 Ohms
1/2 Cycle
1/2 Cycle
HS103DR-HD6090
3-32 VDC
3.0 VDC
1.0 VDC
32 VDC
2.0 mA (3)
(3)
1/2 Cycle
1/2 Cycle
HS103DR-D53TP25D
3-32 VDC
3.0 VDC
1.0 VDC
32 VDC
10 mA @ 5 VDC
450 Ohms
1/2 Cycle
1/2 Cycle
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Status Indicator Display
Weight (typical)
Encapsulation
Recommended Terminal Screw Torque Range:
Thermal pad installed
HS103DR-Dxx90
4000 Vrms
HS103DR-D53TP25D
4000 Vrms
10
9
Ohms
8 pF
-40 to 80˚C
-40 to 125˚C
None
1.39 lb. (631g)
Themally Conductive Epoxy
6-32 Screws - 10 in/lbs. 8-32 Screws - 20 in/lbs.
(Screws dry without grease)
Yes
10
9
Ohms
10 pF
-40 to 80°C
-40 to 125°C
None
1.84 lb (859g)
Themally Conductive Epoxy
6-32 Screws - 10 in/lbs. 8-32 Screws - 20 in/lbs.
(Screws dry without grease)
Yes
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3) Input circuitry for DC control version incorporates active current limiter (HD model only)
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
Agency approvals are for relay only.
E116949 (D2490) E116950 (HD6090, D53TP25D)
10143 UG (D2490, HD6090) VDE 5941 UG (D53TP25D)
Rev. 110811
LR81689 (all)