EEWORLDEEWORLDEEWORLD

Part Number

Search

DK195P

Description
meter dpm 4-20ma pos green bklt
CategoryTopical application    Test and measurement   
File Size604KB,2 Pages
ManufacturerC-TON Industries
Environmental Compliance  
Download Datasheet Parametric Compare View All

DK195P Overview

meter dpm 4-20ma pos green bklt

DK195P Parametric

Parameter NameAttribute value
Datasheets
DK191 Series
Product Photos
Digital Panel Mete
Standard Package1
CategoryIndustrial Controls, Meters
FamilyPanel Meters
TypeProcess Mete
Measuring Range4 ~ 20mA
Display TypeLCD - Black Characters, Green Backligh
Number Of Characters Per Row3.5
Display Characters - Heigh0.449" (11.40mm)
Output Type-
Voltage - SupplyLoop Power, 24VDC (Backlight)
Panel Cutout DimensionsRectangular - 61.00mm x 25.40mm
Mounting TypePanel Mou
Termination StyleScrew Terminal
Ingress Protecti-
Features-
Operating Temperature0°C ~ 50°C
Weigh-
Dynamic CatalogDK191 Series
Associated ProducCDPM1009-ND - CALIBRATOR VOLT .59" LCD BLUCDPM1010-ND - POWER SUPPLY REG 0.5A 24VDC 40VACDPM1002-ND - POWER SUPPLY 24VDC OUT 100MA
Other NamesCDPM1039
DK191 Series
EPIC SERIES
Loop Powered LCD Digital Panel Meters
3½ Digit LCD with Loop Power Board
Features:
◊ Low-cost, high-performance replacement for many OEM DPMs
◊ Optional RED, GREEN or AMBER backlighting
◊ Snap-in bezel mount eliminates mounting hardware
◊ Resistant to RF and EMI
◊ 3½ digits with high-contrast LCD
◊ 4-20 mA loop powered input
◊ User selectable, displayed engineering units
Specifications:
Display:
Backlighting:
Inputs:
Performance:
Environment:
Power Supply:
Mounting:
Connection:
Digits:
Type:
Polarity:
Annuciators:
Decimal Points:
Overrange:
Ranges:
Configuration:
Impedance:
Accuracy:
Conversion Rate:
Normal Mode Rejection:
Common Mode Range:
Common Mode Rej.:
Adjustments:
Warmup:
Temperature Coefficient:
Operating Range:
Storage Range:
Optional Backlight:
3 ½ digits (±1999 counts)
0.45" (11.4 mm) 7 segment LCD
Optional Red Negative (red numbers/black background)
Optional Green Negative (green numbers/black background)
Optional Amber Negative (amber numbers/black background)
Optional Green Positve (black numbers/green background)
automatic, “-” displayed
°F, °C, PSI, % , user selectable, or V, A, KW, PF
3 position, user selectable
three lower order digits blank for inputs >1999 & < -1999
4-20 mA DC
bipolar differential
300Ω nominal
±(0.1% fs + 2 count)
3 per second
>30 db @ 60 Hz
±1 VDC max
>86 dB
span (gain) and zero (offset)
10 minutes typical
± 100 ppm per °C typical
0 to 50 °C
-20 to 70 °C
powered by the milliamp control loop
24 VDC at 35 mA typical
snap-in bezel mount
2 screw terminal (4 with backlight)
Ordering Information:
PART NUMBER
BACKLIGHT COLOR
BACKLIGHT POWER
DK191* ........................................ NO BACKLIGHT ............................................. NONE
DK192* ........................................ NEG AMBER ................................................. 24VDC
DK193* ........................................ NEG GREEN ................................................. 24VDC
DK194* ........................................ NEG RED ...................................................... 24VDC
DK195* ........................................ POS GREEN ................................................. 24VDC
*Add (P) for Power Engineering Units V, A, KW, PF
PW2-24 ..................................................Regulated 120V AC to 24V DC Power Supply
.
PW1.0 ........................................................... 24V AC to adjustable DC output
CPW1.5 ........................................................ 24V AC to adjustable DC output
CVC ..................................................................................................Calibrator
C-TON I
NdusTrIes
• PO B
Ox
172 • S
unaPee
, nH, 03782 • uSa • P
HOne
(603)456-2655 •
email
:
INfO
@
CTONINdusTrIes
.
COm

DK195P Related Products

DK195P DK194P DK193P DK192P DK191P
Description meter dpm 4-20ma pos green bklt meter dpm 4-20ma neg red bklt meter dpm 4-20ma neg green bklt meter dpm 4-20ma neg amber bklt meter dpm 4-20ma NO bklt
Standard Package 1 1 1 - -
Category Industrial Controls, Meters Industrial Controls, Meters Industrial Controls, Meters - -
Family Panel Meters Panel Meters Panel Meters - -
Type Process Mete Process Mete Process Mete - -
Measuring Range 4 ~ 20mA 4 ~ 20mA 4 ~ 20mA - -
Display Type LCD - Black Characters, Green Backligh LCD - Red Characters, Backligh LCD - Green Characters, Backligh - -
Number Of Characters Per Row 3.5 3.5 3.5 - -
Display Characters - Heigh 0.449" (11.40mm) 0.449" (11.40mm) 0.449" (11.40mm) - -
Voltage - Supply Loop Power, 24VDC (Backlight) Loop Power, 24VDC (Backlight) Loop Power, 24VDC (Backlight) - -
Panel Cutout Dimensions Rectangular - 61.00mm x 25.40mm Rectangular - 61.00mm x 25.40mm Rectangular - 61.00mm x 25.40mm - -
Mounting Type Panel Mou Panel Mou Panel Mou - -
Termination Style Screw Terminal Screw Terminal Screw Terminal - -
Operating Temperature 0°C ~ 50°C 0°C ~ 50°C 0°C ~ 50°C - -
Dynamic Catalog DK191 Series DK191 Series DK191 Series - -
Associated Produc CDPM1009-ND - CALIBRATOR VOLT .59" LCD BLUCDPM1010-ND - POWER SUPPLY REG 0.5A 24VDC 40VACDPM1002-ND - POWER SUPPLY 24VDC OUT 100MA CDPM1009-ND - CALIBRATOR VOLT .59" LCD BLUCDPM1010-ND - POWER SUPPLY REG 0.5A 24VDC 40VACDPM1002-ND - POWER SUPPLY 24VDC OUT 100MA CDPM1009-ND - CALIBRATOR VOLT .59" LCD BLUCDPM1010-ND - POWER SUPPLY REG 0.5A 24VDC 40VACDPM1002-ND - POWER SUPPLY 24VDC OUT 100MA - -
Other Names CDPM1039 CDPM1015 CDPM1038 - -
Question + How to implement calculator sequential input in stc12 series microcontroller
I recently came across Topway's large 240160kcw LCD screen. I want to implement a sequential input function like a calculator, that is, press the first number and then the second number to advance the...
disguise2012 51mcu
Information from the official website
The information from the official website is some special information and general examples. I still don't understand it, so I'll share it with you. I don't know if it's useful to you. I'll charge you ...
amanaman DSP and ARM Processors
How to collect digital signals from 100 ports
I need to do an experiment and collect digital signals from 100 ports. Can you experts please tell me how to collect the signals and what circuit or chip to use?...
skey MCU
Please recommend a motor forward and reverse drive
The motor is 5v, connected to the remote control receiver, as long as it can be reversed, I don't want to use a relay, because I want to make the volume small, so I need a packaged motor driver. Thank...
大头叔叔 Motor Drive Control(Motor Control)
Newbie Question
I just came into contact with MSP430 yesterday, and now I have a launchpad. I have many questions, and I hope experts can answer them. Question 1: Can the launchpad be directly connected to 5v vcc? Qu...
lzk031 Microcontroller MCU
Optimum load impedance——PA
When designing an amplifier, the first problem is to determine the optimum load impedance. The reason for the optimum impedance rather than the maximum output power impedance is; The design goal may b...
btty038 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 625  663  2600  873  2115  13  14  53  18  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号