EEWORLDEEWORLDEEWORLD

Part Number

Search

177-740-2-51GS6K5-18BTN

Description
Cable Assembly, 26AWG,
CategoryThe connector    Connector bracket   
File Size858KB,5 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance
Download Datasheet Parametric View All

177-740-2-51GS6K5-18BTN Overview

Cable Assembly, 26AWG,

177-740-2-51GS6K5-18BTN Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7005060634
Reach Compliance Codecompliant
Country Of OriginUSA
YTEOL8.7
Other featuresSTANDARD: MIL-DTL-83513, EMI SHIELDED
CertificationMIL
Conductor surface treatmentSILVER
conductor materialCOPPER
ConnectorSide1MICRO-D FEMALE
ConnectorSide2MICRO-D FEMALE
Connector bracket typeCABLE ASSEMBLY
structureSTRANDED
Cross-sectional area0.129 mm2
DIN complianceNO
IEC complianceNO
insulator materialPOLYTETRAFLUOROETHYLENE
Jacket materialETHYLENE-CHLOROTRIFLUOROETHYLENE
length0.467 mm
MIL complianceYES
Number of conductors51
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
Rated current3 A
Rated voltage150 V
resistance0.125 Ω
shieldYES
stay19X38
Wire gauge26 AWG
Wire and Cable NamesFLEXIBLE CORD AND FIXTURE WIRE
B
SHIELDING EFFECTIVENESS (Db)
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
SHIELDING EFFECTIVENESS (Db)
Micro-D Harness
EMI Performance with Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
MWDM Micro-D
Shielded Cable Assembly
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly labor. 100%
tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair 177-740
cables are furnished with a full complement of white/blue twisted
pair wires.
Integral Shield Termination–The
connector shell has a platform
to accept Band-It shield termination bands. The cable shield braid is
attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding
with Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s
fully shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-
piece connector shell and secured with a stainless steel
Band-Master™ ATS
clamp. These pre-wired, 100% tested
assemblies meet the requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low
shell-to-shell resistance. Available with a variety of wire types and shields, Micro-D shielded assemblies can be
ordered in any length, either single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
A gold-plated stainless steel ground spring on the pin connector mating
face offers substantial improvement in EMI protection. The graphs
compare identical connectors tested with and without ground springs.
EMI Performance without Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
frequency (Hz)
frequency (Hz)
© 2013 Glenair, Inc.
High Performance Micro-D Connectors and Cables
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
B-14
E-Mail: sales@glenair.com
Please convert Verilog code into VHDL
module switch(Din,rd_n,CS_n,databus); input [7:0] Din; input rd_n; input CS_n; output [7:0] databus; reg [7:0] r_databus;always @(negedge rd_n,negedge CS_n) begin case({rd_n,CS_n}) 2'b00:r_databus = Y...
xiaotian_189 FPGA/CPLD
Magnetic-field immunity of digital capacitive isolators
[i=s]This post was last edited by dontium on 2015-1-23 13:38[/i] Magic-field immunity of digital capacitive isolators...
安_然 Analogue and Mixed Signal
DIY activity award-winning speech
Thanks to eeworld and Renesas for providing us with this opportunity. Not only did they give us the opportunity to learn, but they also gave us prizes. Such good things are rare. I have heard that Ren...
damiaa Renesas Electronics MCUs
Show the WEBENCH design process + 3.3V1A power conversion circuit solution
1. Design title: 3.3V1A power conversion circuit scheme DC4V-9V conversion 3.3V1A circuit 2. Design process Enter the webench design interface [url=https://www.eeworld.com.cn/huodong/201405_TI_webench...
qwqwqw2088 Analogue and Mixed Signal
The coolest and most realistic simulated robot, count how many "bones" it is made of?
It looks a bit like yoga. Haha, it is indeed made by a talented person. [[i] This post was last edited by hanker510 on 2008-12-9 10:00 [/i]]...
hanker510 Robotics Development
vivi-bootloader issues
What do the multiple b 1b statements in the head.s file mean? As follows @ All LED on mov r1, #GPIO_CTL_BASE add r1, r1, #oGPIO_F ldr r2,=0x55aa str r2, [r1, #oGPIO_CON] mov r2, #0xff str r2, [r1, #oG...
ladyhunter Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2366  2614  1738  1549  1466  48  53  35  32  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号