EEWORLDEEWORLDEEWORLD

Part Number

Search

8575K23-20

Description
Toggle Switch, 4PDT, Momentary, 18A, 28VDC, Screw Terminal, Locking Lever Actuator, Panel Mount-threaded,
CategoryMechanical and electronic products    switch   
File Size154KB,5 Pages
ManufacturerSafran Group
Download Datasheet Parametric View All

8575K23-20 Overview

Toggle Switch, 4PDT, Momentary, 18A, 28VDC, Screw Terminal, Locking Lever Actuator, Panel Mount-threaded,

8575K23-20 Parametric

Parameter NameAttribute value
MakerSafran Group
Reach Compliance Codecompliant
Actuator typeLOCKING LEVER
body width33.5 mm
body height40.6 mm
Body length or diameter41.6 mm
Contact (AC) maximum rated R load11A@115VAC
Maximum contact current (AC)11 A
Maximum contact current (DC)18 A
Contact (DC) maximum rated R load18A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Electrical life20000 Cycle(s)
Installation featuresPANEL MOUNT-THREADED
Maximum operating temperature71 °C
Minimum operating temperature-65 °C
sealENVIRONMENTALLY SEALED
surface mountNO
Switch actionMOMENTARY
switch function4PDT
Switch typeTOGGLE SWITCH
Termination typeSCREW
MILITARY—ENVIRONMENTALLY SEALED SWITCHES
Series—8573, 8574, 8575
MIL-S-3950 IWTS Lever Locks
FEATURES
SPECIFICATIONS
• Environmentally sealed
• Environmentally sealed per MIL-S-3950
• 1, 2, and 4 pole circuitry
• MS approved and QPL’d per MIL-S-3950
• 2 & 3 position with maintained and
• Thermoset molding materials meet flame
momentary action
retardant requirements
• Integrated wire termination system
• Bushing: 15/32" - 32 thread
(IWTS) for ease of wiring
• Temperature Range: -85°F to +160°F
• Terminal numbers molded into silicone
(-65°C to +71°C)
base seal
• Accepts MIL-C-39029/1-101 pin
• Life: 20,000 operations at rated load
40,000 operations mechanical life
CURRENT RATINGS
No. of Catalog
Type of
Poles Number Operation
28VDC
Lamp Resistive Inductive
Load
Load
Load
5
20
15
4
15
10
7
20
15
5
18
10
5
20
12
4
18
10
115VAC
60 or 400Hz
Lamp Resistive Inductive
Load
Load
Load
3
15
10
2
15
7
4
15
15
2
11
8
4
15
15
2
11
8
1
2
4
8573
8574
8575
Maintained
Momentary
Maintained
Momentary
Maintained
Momentary
Minimum Rating: “Intermediate Current” per MIL-S-3950
LEVER LOCK SELECTION TABLE – T er minals Accept W
Ter minals Accept W
ir e Contact Within Dimensional Limits of M39029/1-102 for -16 wire size
ir e Contact Within Dimensional Limits of M39029/1-101 for -20 wire size
8573
CIRCUIT WITH LEVER IN...
Up
Position
Center
Position
Down
Position (Keyway)
Lever
x
Lock
Bushing
Style
8574
TWO POLE
Flush Screw Terminals
MS Part
Catalog
Number
Number
8574K1-16
K27-16
K5-16
K2-16
K28-16
8574K3-16
K29-16
K30-16
K31-16
K32-16
8574K33-16
K4-16
K34-16
K10-16
K35-16
8574K9-16
K6-16
K36-16
K7-16
K16-16
8574K37-16
K38-16
K11-16
K22-16
K20-16
8574K12-16
K39-16
K14-16
K15-16
K21-16
8574K19-16
K18-16
K40-16
K41-16
K13-16
8575
FOUR POLE
Flush Screw Terminals
MS Part
Catalog
Number
Number
MS27783-21A
-21B
-21D
-21E
-21F
MS27783-21G
-21H
-21J
-21K
-21L
MS27783-21M
-21N
-21P
-22D
-22F
MS27783-22G
-23D
-23F
-23G
-24E
MS27783-24F
-24K
-24M
-25F
-26F
MS27783-27E
-27L
-27N
-28E
-29F
MS27783-30F
-31E
-31F
-31K
-31L
8575K1-16
K27-16
K5-16
K2-16
K28-16
8575K3-16
K29-16
K30-16
K31-16
K32-16
8575K33-16
K4-16
K34-16
K10-16
K35-16
8575K9-16
K6-16
K36-16
K7-16
K16-16
8575K37-16
K38-16
K11-16
K22-16
K20-16
8575K12-16
K39-16
K14-16
K15-16
K21-16
8575K19-16
K18-16
K40-16
K41-16
K13-16
ONE POLE
Flush Screw Terminals
MS Part
Catalog
Number
Number
*
*
*
ON§
OFF§
ON
A
ON
OFF§
ON
B
ON§
OFF
ON
D
ON
OFF§
ON
E
ON§
OFF
ON
F
ON
OFF
ON
G
ON§
OFF§
ON
H
ON
OFF
ON
J
ON§
OFF§
ON
K
ON
OFF§
ON
L
ON§
OFF
ON
M
ON
OFF
ON
N
ON
OFF§
ON
P
ON§
NONE
OFF
D
ON§
NONE
OFF
F
ON
NONE
OFF
G
ON§
NONE
ON
D
ON§
NONE
ON
F
ON
NONE
ON
G
ON
OFF§
NONE
E
ON§
OFF
NONE
F
ON§
OFF§
NONE
K
ON§
OFF
NONE
M
ON§
OFF
NONE
F
ON§
NONE
ON
F
ON
OFF§
ON
E
ON
OFF§
ON
L
ON
OFF
ON
N
NONE
OFF§
ON
E
ON§
NONE
OFF
F
OFF§
NONE
ON
F
ON
OFF§
ON
E
ON§
OFF
ON
F
ON§
OFF§
ON
K
ON
OFF§
ON
L
Momentary contact.
§
Indicates direction against which lever is locked.
*
*
*
*
*
*
*
*
*
*
*
*
*
MS27781-21A
8573K1-16
MS27782-21A
-21B
K27-16
-21B
-21D
K5-16
-21D
-21E
K2-16
-21E
-21F
K28-16
-21F
MS27781-21G
8573K3-16
MS27782-21G
-21H
K29-16
-21H
-21J
K30-16
-21J
-21K
K31-16
-21K
-21L
K32-16
-21L
MS27781-21M
8573K33-16
MS27782-21M
-21N
K4-16
-21N
-21P
K34-16
-21P
-22D
K10-16
-22D
-22F
K35-16
-22F
MS27781-22G
8573K9-16
MS27782-22G
-23D
K6-16
-23D
-23F
K36-16
-23F
-23G
K7-16
-23G
-24E
K16-16
-24E
MS27781-24F
8573K37-16
MS27782-24F
-24K
K38-16
-24K
-24M
K11-16
-24M
-25F
K22-16
-25F
-26F
K20-16
-26F
MS27781-27E
8573K12-16
MS27782-27E
-27L
K39-16
-27L
-27N
K14-16
-27N
-28E
K15-16
-28E
-29F
K21-16
-29F
MS27781-30F
8573K19-16
MS27782-30F
-31E
K18-16
-31E
-31F
K40-16
-31F
-31K
K41-16
-31K
31L
K13-16
-31L
See page 73 for circuit diagrams.
x
Reference bushing styles on Page 42.
Amplifier Problems
I use an amplifier to amplify the signal. The amplifier uses positive and negative power supplies, but the output signals are all positive. The signals that should have been negative have all become p...
wuli1314 Analog electronics
Advanced Driver Assistance System Solution Series Introduction—Digital Camera
In recent years, with the continuous improvement of people's demand for driving safety, the continuous maturity of advanced driver assistance system (ADAS) related technologies, and the rapid developm...
alan000345 TI Technology Forum
I watched the video tutorial in detail and expanded some of it for everyone!
When we talk about uboot debug in the course, we need to load img. At this time, if there is no auxiliary boot device such as SD card, we need to use CCS to load the img file in ELF format in Uboot. T...
wuyanyanke DSP and ARM Processors
Modelsim_Win64_10.1 and above versions ultimate crack (with answers to common problems)
[url=][attach]237865[/at[/url][url=]tach]Modelsim_10.1c_crack.rar[/url] In fact, cracking is very simple. Simply put, it only takes 4 steps: 1. Download the cracking tool and install the Modelsim soft...
suifeng_lll FPGA/CPLD
Atmel SAM D21 Xplained Pro (02) First Example
Having just solved the USB driver problem, we need to confirm whether the board can run normally. The fastest and most direct way is to directly import the existing examples. In addition to confirming...
slotg MCU
Prize-winning quiz | ADI application tour - water quality and gas monitoring
In the real world, water quality and gas monitoring are closely related to human life.With the country's investment in environmental protection, the demand for analysis, management, protection and det...
EEWORLD社区 Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1270  2468  674  2889  2493  26  50  14  59  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号