3228

High-accuracy ±0.5% current and isolated voltage measurement reference design using 24-bit delta-sigma ADC

TIDA-00835

 
Overview

This analog front end (AFE) design shows how to connect two or more Σ-Δ ADCs for simultaneous sampling and how to expand the number of input channels to provide maximum flexibility. Precision current measurement is achieved by connecting the AFE to a current transformer (CT) and a Rogowski coil. Likewise, accurate voltage measurements are achieved using resistive voltage dividers without and with isolation amplifiers. The AFE can be configured to measure unipolar or bipolar inputs. The required power is provided onboard. Additionally, diagnostics can be integrated into one design, as shown in TIDA-00810.

characteristic
  • ● Precision data acquisition over a wide input range using 4-channel simultaneous sampling 24-bit Σ-Δ ADC
  • ● Channel expansion by connecting multiple devices with simultaneous sampling synchronized to a buffered common clock
  • ● Current measurements – verify performance using current transformers or Rogowski coils with hardware integrator
  • ● Voltage measurement – ​​Verify performance using voltage divider (PD) without and with isolation amplifier (basic or reinforced isolation)

Backlog Impt notice changes Backlog Impt notice changes end
参考设计图片
×

Blockdiagram

 
 
Search Datasheet?

Supported by EEWorld Datasheet

Forum More
Update:2025-06-24 02:11:41

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
community

Robot
development
community

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号