, and a 30K frequency resistor set, the actual operating frequency is 234kHz. (See image below for 5.8V 3A). During long-term operation
, the temperature is around 65 degrees Celsius. A serious problem is poor load response; no solution found. The power drops when suddenly under full load from no-load. (See image below for no feedforward capacitor, and image
below for 100pF feedforward capacitor). The larger the feedforward capacitor, the slower the output voltage recovery
. It recovers at around 16W output power; at higher power, the output trips to protection.
All reference designs on this site are sourced from major semiconductor manufacturers or collected online for learning and research. The copyright belongs to the semiconductor manufacturer or the original author. If you believe that the reference design of this site infringes upon your relevant rights and interests, please send us a rights notice. As a neutral platform service provider, we will take measures to delete the relevant content in accordance with relevant laws after receiving the relevant notice from the rights holder. Please send relevant notifications to email: bbs_service@eeworld.com.cn.