Two motor delay control circuits
Source: InternetPublisher:偷熊计划 Keywords: Control circuit motor time relay AC contactor Updated: 2021/01/21
The delay time of the time relay is set to 5s. After checking that the wiring is correct, connect the main power switch QS on the platform to the start button
SB2, and the motor M1 starts running; after the delay relay KT is delayed for 5s, its moving and closing contacts are closed, and the KM2 coil is power, connect the KM2 main
circuit, and the motor MZ runs. Observe the action of the AC contactor , time relay and motor; change the delay time of the time relay
to 1Os and repeat the above operation. During the experiment, the motor M2 can be replaced by an incandescent lamp.
- DIY a simple fire alarm
- How to Make a Simple 2-Step Arduino Programmable Timer Circuit
- Build a Smart Garage Door Opener Using a Raspberry Pi
- Tutorial for building a remote-controlled Arduino Air-Boat
- One-way rotation circuit of motor controlled by contactor
- Add one more component to improve the phase failure protection function
- Design and principle analysis of practical electric curtain remote control device
- IGBT modules block overcurrent by controlling the gate
- Design and manufacture of three-phase motor protection circuit
- Electric vehicle battery charging protection circuit
- Micro remote control receiving and control circuit
- Electronic rhythm control circuit
- Electric sewing machine power saving circuit
- Car window control circuit
- PLC chain alarm control circuit used in production process
- Multi-pole leakage protector circuit a
- Haier KFR-25GW air conditioner control circuit schematic diagram
- One of the AC contactor low voltage starting circuits
- AC contactor detection control circuit
- Energy-saving method of changing AC contactor to DC operation