• You can log in to your eeworld account to continue watching:
  • DISSIPATION INTO AMBIENT MEDIUM - 310.14(A)(3), IN 1(3)
  • Login
  • Duration:3 minutes and 16 seconds
  • Date:2022/09/28
  • Uploader:Lemontree
Introduction
keywords: electronic system
Switchboards are designed with busbars for fuses or circuit breakers that are used for protecting and supplying feeders and branch circuits. Panelboards are designed with a permanently installed main circuit breaker or single set of fuses for disconnecting the number of circuit breakers or fuseholders installed to protect and supply feeders or branch circuits.

SUPPORT AND ARRANGEMENT OF BUSBARS AND CONDUCTORS
408.3

Busbars shall be held firmly in place in the enclosure and shall be arranged in such a way to allow adequate space for conductors to be terminated. Busbars shall be sized with enough capacity to handle the normal currents in amps of the electrical system. In addition, they shall carry safely any type of short-circuit or ground-fault condition.

CONDUCTORS AND BUSBARS ON A SWITCHBOARD OR PANELBOARD
408.3(A)

Conductors and busbars on a switchboard, panelboard, or control board shall be so located as to be free from physical damage. Service sections of such boards shall be separated from the other electrical components. These components shall be properly secured in an approved manner. 

Note, conductors entering a certain section shall terminate in such section, except where it is not practical for control, interconnecting conductors, or other conditions of use.

OVERHEATING AND INDUCTIVE HEATING
408.3(B)

The arrangement of busbars and conductors shall be such as to avoid overheating due to inductive effects. The inductive effect of each conductor is neutralized when grouping all conductors together. To accomplish the minimizing of heating effects, the ungrounded (phase) conductors, grounded (neutral) conductors, and equipment grounding conductors, where used, shall be in the same enclosure, raceway, cable, cord, etc. (See Figure 7-1)

Unfold ↓

You Might Like

Recommended Posts

Tietto Recruitment: Senior RF Engineer
Tieto (formerly Diyitong) Information Technology Co., Ltd. (Tieto), founded in 1968, is a Nordic wholly foreign-owned group company engaged in software solutions, listed on the Helsinki and Stockholm
xiao_lili0 Recruitment
About wince’s IP
The wince simulator I use in EVC, I want to get the IP address of the wince simulator. After using the following program, only the name is displayed but the IP address cannot be displayed. What's goin
zglckf Embedded System
There is an abnormal data 3F in the uart0 received data
Hello everyone, in a project using Renesas chip r5f100mg, using uart0 to send and receive, the data received by the corresponding test host computer has an abnormal data 3f in the message header, and
raining55 Renesas Electronics MCUs
Help: I can’t figure out the humidity to one decimal place, and I don’t know why!
The driver for SHT21 I use is the driver provided by Mr. Hu Lei.I basically didn’t make any changes to the temperature and humidity calculation program: as follows:// Command--0xF3 measures temperatur
lzm2008 DIY/Open Source Hardware
Antenna Aperture Tuning eBook
[i=s]This post was last edited by alan000345 on 2019-5-7 11:11[/i] Higher data rates, more antennas, less space. Antenna efficiency plays a critical role in the overall RF performance of smartphones.
alan000345 RF/Wirelessly
FRAM Reliability Explanation
FRAM Reliability ExplanationFRAM How-to and Best Practices FRAM Reliability Explanation
Jacktang Microcontroller MCU

Recommended Content

Hot VideosMore

可能感兴趣器件

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号