Switchboards are designed with busbars for fuses or circuit breakers that are used for protecting and supplying feeders and branch circuits. Panelboards are designed with a permanently installed main circuit breaker or single set of fuses for disconnecting the number of circuit breakers or fuseholders installed to protect and supply feeders or branch circuits.

SUPPORT AND ARRANGEMENT OF BUSBARS AND CONDUCTORS
408.3

Busbars shall be held firmly in place in the enclosure and shall be arranged in such a way to allow adequate space for conductors to be terminated. Busbars shall be sized with enough capacity to handle the normal currents in amps of the electrical system. In addition, they shall carry safely any type of short-circuit or ground-fault condition.

CONDUCTORS AND BUSBARS ON A SWITCHBOARD OR PANELBOARD
408.3(A)

Conductors and busbars on a switchboard, panelboard, or control board shall be so located as to be free from physical damage. Service sections of such boards shall be separated from the other electrical components. These components shall be properly secured in an approved manner. 

Note, conductors entering a certain section shall terminate in such section, except where it is not practical for control, interconnecting conductors, or other conditions of use.

OVERHEATING AND INDUCTIVE HEATING
408.3(B)

The arrangement of busbars and conductors shall be such as to avoid overheating due to inductive effects. The inductive effect of each conductor is neutralized when grouping all conductors together. To accomplish the minimizing of heating effects, the ungrounded (phase) conductors, grounded (neutral) conductors, and equipment grounding conductors, where used, shall be in the same enclosure, raceway, cable, cord, etc. (See Figure 7-1)

Unfold ↓

You Might Like

Recommended Posts

Urgent!!! NK files larger than 32M cannot be downloaded into the system!
I use 2450, and the BSP package config.bib file defines ROMSIZE = 02000000, which means the maximum nk.bin can only be 32M. If I add a lot of components, such as using a Chinese system, nk.bin will ex
winning Embedded System
Has anyone done any database application (SQLCE)?
I want to develop a database in the wince environment first, using VS2005, but after downloading it to the board, it can't run after the power is off, saying that the file or assembly name "System.Dat
lmx5078 Embedded System
Request IFS DDK For XP
I'm looking for IFS DDK development environment. Thank you very much. You can send it to my email: crsit@126.com. Thank you, thank you~~!
lmjxcg Embedded System
Design of digital pressure gauge based on MSP430 single chip microcomputer
Help: Design of digital pressure gauge based on MSP430 microcontroller
243677763 MCU
NXP Semiconductors launches a new 32-bit microcontroller LPC800 for 8-bit applications
NXP Semiconductors NV recently announced a major move to completely replace 8-bit microcontrollers: its latest 32-bit microcontroller for 8-bit applications, the LPC800, has a revolutionary breakthrou
zhaojun_xf NXP MCU
Error with binutils...
Why does make check binutils fail? $./configure --target=$TARGET --prefix=$PREFIX $make check root@johaness-laptop:/tars/BuildDir/binutils# make check make[1]: Entering directory `/tars/BuildDir/binut
zhouxinsee Embedded System

Recommended Content

Hot VideosMore

可能感兴趣器件

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号