• You can log in to your eeworld account to continue watching:
  • ILLUMINATION FOR ELECTRICAL EQUIPMENT IN COMMERCIAL & INDUSTRIAL LOCATIONS - 110.26(D)
  • Login
  • Duration:3 minutes and 18 seconds
  • Date:2022/09/28
  • Uploader:Lemontree
Introduction
keywords: electronic system
Switchboards are designed with busbars for fuses or circuit breakers that are used for protecting and supplying feeders and branch circuits. Panelboards are designed with a permanently installed main circuit breaker or single set of fuses for disconnecting the number of circuit breakers or fuseholders installed to protect and supply feeders or branch circuits.

SUPPORT AND ARRANGEMENT OF BUSBARS AND CONDUCTORS
408.3

Busbars shall be held firmly in place in the enclosure and shall be arranged in such a way to allow adequate space for conductors to be terminated. Busbars shall be sized with enough capacity to handle the normal currents in amps of the electrical system. In addition, they shall carry safely any type of short-circuit or ground-fault condition.

CONDUCTORS AND BUSBARS ON A SWITCHBOARD OR PANELBOARD
408.3(A)

Conductors and busbars on a switchboard, panelboard, or control board shall be so located as to be free from physical damage. Service sections of such boards shall be separated from the other electrical components. These components shall be properly secured in an approved manner. 

Note, conductors entering a certain section shall terminate in such section, except where it is not practical for control, interconnecting conductors, or other conditions of use.

OVERHEATING AND INDUCTIVE HEATING
408.3(B)

The arrangement of busbars and conductors shall be such as to avoid overheating due to inductive effects. The inductive effect of each conductor is neutralized when grouping all conductors together. To accomplish the minimizing of heating effects, the ungrounded (phase) conductors, grounded (neutral) conductors, and equipment grounding conductors, where used, shall be in the same enclosure, raceway, cable, cord, etc. (See Figure 7-1)

Unfold ↓

You Might Like

Recommended Posts

About writing registry functions
Now I want to modify the HIVE registry to modify the IP, SUBNETMASK, GATEWAY address. I run it on the development version of JZ4730, using the WINCE system. After running it, I found that there was no
kevinliu Embedded System
Atmel launches six new 8051 single-cycle core MCUs, reducing power consumption by 80%
Atmel has announced the launch of four 14-pin and two 16-pin new microcontrollers based on its 8051 single-cycle core . Atmel's single-cycle core architecture requires only one clock cycle to read a b
frozenviolet 51mcu
Brief Analysis of Wireless Power Knowledge
This article is a translation from the English version of DevicePlus.com .Wireless power is becoming more common thanks to Apple and Android phone manufacturers. But if you’ve ever seen an electrical
ohahaha RF/Wirelessly
Use of TPS2350
I would like to ask: Has anyone used TPS2350? I would like to use it. Can I learn from your valuable experience? Thank you!
xujian2000 Analogue and Mixed Signal
I would like to ask, how wide can the bandwidth of the RF amplifier be? How many bands are needed for 30M-1.5G?
Please tell me, how wide can the bandwidth of the RF amplifier be? How many bands are needed for 30M-1.5G? eeworldpostqq
blink Analog electronics
ZLGCABNTest
This keil can only open one project file at a time, that is, it can only download one project file to the board, so how to complete their data sending and receiving? Then use ZLGCANTest universal test
xiepeilin Embedded System

Recommended Content

可能感兴趣器件

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号