keywords: electronic system
Switchboards are designed with busbars for fuses or circuit breakers that are used for protecting and supplying feeders and branch circuits. Panelboards are designed with a permanently installed main circuit breaker or single set of fuses for disconnecting the number of circuit breakers or fuseholders installed to protect and supply feeders or branch circuits.

SUPPORT AND ARRANGEMENT OF BUSBARS AND CONDUCTORS
408.3

Busbars shall be held firmly in place in the enclosure and shall be arranged in such a way to allow adequate space for conductors to be terminated. Busbars shall be sized with enough capacity to handle the normal currents in amps of the electrical system. In addition, they shall carry safely any type of short-circuit or ground-fault condition.

CONDUCTORS AND BUSBARS ON A SWITCHBOARD OR PANELBOARD
408.3(A)

Conductors and busbars on a switchboard, panelboard, or control board shall be so located as to be free from physical damage. Service sections of such boards shall be separated from the other electrical components. These components shall be properly secured in an approved manner. 

Note, conductors entering a certain section shall terminate in such section, except where it is not practical for control, interconnecting conductors, or other conditions of use.

OVERHEATING AND INDUCTIVE HEATING
408.3(B)

The arrangement of busbars and conductors shall be such as to avoid overheating due to inductive effects. The inductive effect of each conductor is neutralized when grouping all conductors together. To accomplish the minimizing of heating effects, the ungrounded (phase) conductors, grounded (neutral) conductors, and equipment grounding conductors, where used, shall be in the same enclosure, raceway, cable, cord, etc. (See Figure 7-1)

Unfold ↓

You Might Like

Recommended Posts

About serial communication
I would like to ask you all... I can't receive data using the serial port debugging assistant... What could be the reason?~~~~
cocalli Embedded System
【Essay Contest with Prizes】Keysight Thanksgiving Month: Write an Essay and Get an Oscilloscope! Are you the top scorer?
[size=3][color=#000080][b]Keysight Technology Oscilloscope Thanksgiving Month Essay Contest is now open! [/b][/color][/size] [size=3][color=#000080][b]Many gifts are ready, just waiting for your wonde
EEWORLD社区 Test/Measurement
Design of Function Signal Generator Based on 51 Single Chip Microcomputer
The voltage is required to be 1-5v and the frequency is 1-1000k. Please help me, I will reward you with a lot of money! ! ! :faint:
wh5212581 51mcu
Improve the uniformity of PCB solder mask thickness
Improve the uniformity of PCB solder mask thickness
lorant PCB Design
Partial information___Original STC microcontroller manufacturer Shengquan Technology Megawin_8051
Partial information___Original STC microcontroller manufacturer Shengquan Technology
Megawin_8051 51mcu
USB to TTL module USB driver for the Corelinks SinA33 development board
USB to TTL module for the Corelinks SinA33 development board
babyking Embedded System

Recommended Content

Hot VideosMore

可能感兴趣器件

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号