• You can log in to your eeworld account to continue watching:
  • MINIMUM WIRE-BENDING SPACE - 408.3(G)
  • Login
  • Duration:3 minutes and 43 seconds
  • Date:2022/09/28
  • Uploader:Lemontree
Introduction
keywords: electronic system
Switchboards are designed with busbars for fuses or circuit breakers that are used for protecting and supplying feeders and branch circuits. Panelboards are designed with a permanently installed main circuit breaker or single set of fuses for disconnecting the number of circuit breakers or fuseholders installed to protect and supply feeders or branch circuits.

SUPPORT AND ARRANGEMENT OF BUSBARS AND CONDUCTORS
408.3

Busbars shall be held firmly in place in the enclosure and shall be arranged in such a way to allow adequate space for conductors to be terminated. Busbars shall be sized with enough capacity to handle the normal currents in amps of the electrical system. In addition, they shall carry safely any type of short-circuit or ground-fault condition.

CONDUCTORS AND BUSBARS ON A SWITCHBOARD OR PANELBOARD
408.3(A)

Conductors and busbars on a switchboard, panelboard, or control board shall be so located as to be free from physical damage. Service sections of such boards shall be separated from the other electrical components. These components shall be properly secured in an approved manner. 

Note, conductors entering a certain section shall terminate in such section, except where it is not practical for control, interconnecting conductors, or other conditions of use.

OVERHEATING AND INDUCTIVE HEATING
408.3(B)

The arrangement of busbars and conductors shall be such as to avoid overheating due to inductive effects. The inductive effect of each conductor is neutralized when grouping all conductors together. To accomplish the minimizing of heating effects, the ungrounded (phase) conductors, grounded (neutral) conductors, and equipment grounding conductors, where used, shall be in the same enclosure, raceway, cable, cord, etc. (See Figure 7-1)

Unfold ↓

You Might Like

Recommended Posts

30th Anniversary of the Release of EEE 802.3(TM) Ethernet Standard
On June 23, 1983, IEEE, the world's largest professional technical association dedicated to technological development and benefiting mankind, commemorated the 30th anniversary of the release of the IE
wstt Embedded System
Graphene, supercapacitors and 18650, if you still don’t understand, don’t go home for the New Year (Repost)
[i=s]This post was last edited by Bai Ding on 2016-2-5 22:59[/i] Reposted from [url=http://mp.weixin.qq.com/s?__biz=MjM5NDQ0NjM5Mg==&mid=401439742&idx=1&sn=6d2f09eeda89ca7617ecc34e0e6714a8&3rd=MzA3MDU
白丁 Power technology
M4 Task 3: (Completed) Implement the display interface of three-axis accelerated ADC sampling on LCD
The three-axis acceleration on the MSP-EXP430FR5739 is very powerful! I decided to use it on the M4 board to measure the inclination! I worked hard all night and came up with an interface, which can b
anananjjj Microcontroller MCU
How to define bit variables?
wacrt Microcontroller MCU
Problems with powering the microcontroller
How to draw a 220v AC to 5v DC conversion circuit? Can it be used to power a 51 microcontroller?
396502099 Embedded System
Can the ne555 plus integrator circuit generate a 50KHz triangular carrier?
Can the ne555 plus integration circuit generate a 50KHz triangular carrier? eeworldpostqq
xiefei Power technology

Recommended Content

Hot ArticlesMore

Circuit

可能感兴趣器件

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号