Switchboards are designed with busbars for fuses or circuit breakers that are used for protecting and supplying feeders and branch circuits. Panelboards are designed with a permanently installed main circuit breaker or single set of fuses for disconnecting the number of circuit breakers or fuseholders installed to protect and supply feeders or branch circuits.

SUPPORT AND ARRANGEMENT OF BUSBARS AND CONDUCTORS
408.3

Busbars shall be held firmly in place in the enclosure and shall be arranged in such a way to allow adequate space for conductors to be terminated. Busbars shall be sized with enough capacity to handle the normal currents in amps of the electrical system. In addition, they shall carry safely any type of short-circuit or ground-fault condition.

CONDUCTORS AND BUSBARS ON A SWITCHBOARD OR PANELBOARD
408.3(A)

Conductors and busbars on a switchboard, panelboard, or control board shall be so located as to be free from physical damage. Service sections of such boards shall be separated from the other electrical components. These components shall be properly secured in an approved manner. 

Note, conductors entering a certain section shall terminate in such section, except where it is not practical for control, interconnecting conductors, or other conditions of use.

OVERHEATING AND INDUCTIVE HEATING
408.3(B)

The arrangement of busbars and conductors shall be such as to avoid overheating due to inductive effects. The inductive effect of each conductor is neutralized when grouping all conductors together. To accomplish the minimizing of heating effects, the ungrounded (phase) conductors, grounded (neutral) conductors, and equipment grounding conductors, where used, shall be in the same enclosure, raceway, cable, cord, etc. (See Figure 7-1)

Unfold ↓

You Might Like

Recommended Posts

What is a single board
I saw in the book "Huawei EMC Information" that single boards are frequently mentioned: single board layer number, single board power layer number, single board signal layer number, etc. I don't under
afreebird Embedded System
Misunderstandings about UPS Power Supply Lightning Protection
[color=#3e3e3e]Without any sign of lightning, the built-in lightning arrester of the UPS being operated by the user is broken, but the UPS is still working normally. In fact, when lightning strikes in
木犯001号 Power technology
RDA fails when performing a pull operation, [,,,Database name,,]. I hope an expert can help me. The code is as follows
void CRDAExamDlg::OnBtnPull(){ISSCERDA * pCERDA = NULL;BSTR bstrConnectStr;BSTR bstrLocalConnectStr;BSTR bstrLocalTableName;BSTR bstrQueryStr;BSTR bstrErrorTableName;RDA_TRACKOPTION trackOption;//CoIn
502815059 Embedded System
EEWORLD University Hall - Application strategies for measurement and control questions in electronic design competitions
Application strategies for measurement and control questions in electronic design competitions : https://training.eeworld.com.cn/course/5829Teacher Tang talks about the application strategies of measu
JFET Test/Measurement

Recommended Content

可能感兴趣器件

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号